Octavian Narcis Ionescu

Dr. Octavian Narcis Ionescu

INCD-IMT Bucharest
+2
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 September 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
Alina-Cristina BuneaAlina-Cristina Bunea
Alina-Cristina Bunea
VDVioleta Dediu
Violeta Dediu
Edwin Alexandru LaszloEdwin Alexandru Laszlo
Edwin Alexandru Laszlo
FPFlorian PISTRITU
Florian PISTRITU
MCMihaela Carp
Mihaela Carp
Ciprian IliescuCiprian Iliescu
Ciprian Iliescu
Real-time “on-body” monitoring of human physiological signals through wearable systems developed on flexible substrates (e-skin) is the next target in human health control and prevention, while an alternative to bulky diagnostic devices routinely used in clinics. The present work summarizes the recent trends in the development of e-skin systems. Firstly, we revised the material development for e-skin systems. Secondly, aspects related to fabrication techniques were presented. Next, the main applications of e-skin systems in monitoring, such as temperature, pulse, and other bio-electric signals related to health status, were analyzed. Finally, aspects regarding the power supply and signal processing were discussed. The special features of e-skin as identified contribute clearly to the developing potential as in situ diagnostic tool for further implementation in clinical practice at patient personal levels.

26 October 2020 in Materials
Verified
Journal Article
Open access
PDF file
AMAthina Maniadi
Athina Maniadi
Maria VamvakakiMaria Vamvakaki
Maria Vamvakaki
Mirela Petruta SucheaMirela Petruta Suchea
Mirela Petruta Suchea
ITIoan Valentin Tudose
Ioan Valentin Tudose
MPMarian Popescu
Marian Popescu
Emmanouel KoudoumasEmmanouel Koudoumas
Emmanouel Koudoumas
The incorporation of graphene nanoplatelets (GnPs) within a polymer matrix can play an important role in the physical properties and the functionality of the composite material. Composites consisting of low-density polyethylene (LDPE) and GnPs of different concentrations were developed by mixing GnPs with a molten form of the polymeric matrix. The effect of the GnPs content on the morphological, structural, and electrical properties of the composites were investigated. As shown, graphene presence and its concentration significantly modified the polymer matrix properties, a behavior that can be employed for tailoring its applicability in electrical applications. It was found that the increase of the graphene platelets concentration seems to promote the formation of graphene agglomerates, air gaps, and inhomogeneities, while higher dielectric constant/lower dielectric losses can be achieved.

29 January 2022 in Nanomaterials
Verified
Journal Article
Open access
PDF file
ITIoan Valentin Tudose
Ioan Valentin Tudose
KMKyriakos Mouratis
Kyriakos Mouratis
OIOctavian Narcis Ionescu
Octavian Narcis Ionescu
Cosmin RomanitanCosmin Romanitan
Cosmin Romanitan
Cristina PachiuCristina Pachiu
Cristina Pachiu
Emmanouel KoudoumasEmmanouel Koudoumas
Emmanouel Koudoumas
The development of materials offering electromagnetic interference (EMI) shielding is of significant consideration, since this can help in expanding the lifetime of devices, electromagnetic compatibility, as well as the protection of biological systems. Conductive paints used widely today in electromagnetic interference (EMI) shielding applications are often based on organic solvents that can create safety issues due to the subsequent environment problems. This paper concerned the development of eco-friendly conductive water-based paints for use in EMI-shielding applications. Graphene nanoplatelets, polyaniline emeraldine (PANI) doped with poly(styrene sulfonic acid) (PSS) or HCl or HBr and poly(3,4-ethylenedioxythiophene) poly(styrene sulfonic acid) (PEDOT:PSS) in various ratios were employed in a water base for developing the paints. The target was to develop homogeneous water-based paint-like fluid mixtures easily applied onto surfaces using a paint brush, leading in homogeneous, uniform, opaque layers, draying fast in air at room temperature, and having quite good electrical conductivity that can offer efficient EMI-shielding performance. The results of this parametric trial indicated the optimum compositions leading in paints with optimized properties that can result in uniform, homogeneous, and conductive layers up to a thickness of over 500 μm without deformation and cracking, offering attenuation of up to 60 dBs of incoming GHz electromagnetic radiation. In addition, the structural and morphological characteristics of these paints were studied in detail.

28 July 2020 in Nanomaterials
Verified
Journal Article
Open access
PDF file
Petronela PascariuPetronela Pascariu
Petronela Pascariu
MHMihaela Homocianu
Mihaela Homocianu
NONiculae Olaru
Niculae Olaru
AAAnton Airinei
Anton Airinei
OIOctavian Narcis Ionescu
Octavian Narcis Ionescu
New molybdenum trioxide-incorporated ZnO materials were prepared through the electrospinning method and then calcination at 500 °C, for 2 h. The obtained electrospun ZnO:MoO3 hybrid materials were characterized by X-ray diffraction, scanning and transmission electron microscopies, ultraviolet (UV)-diffuse reflectance, UV–visible (UV–vis) absorption, and photoluminescence techniques. It was observed that the presence of MoO3 as loading material in pure ZnO matrix induces a small blue shift in the absorption band maxima (from 382 to 371 nm) and the emission peaks are shifted to shorter wavelengths, as compared to pure ZnO. Also, a slight decrease in the optical band gap energy of ZnO:MoO3 was registered after MoO3 incorporation. The photocatalytic performance of pure ZnO and ZnO:MoO3 was assessed in the degradation of rhodamine B (RhB) dye with an initial concentration of 5 mg/L, under visible light irradiation. A doubling of the degradation efficiency of the ZnO:MoO3 sample (3.26% of the atomic molar ratio of Mo/Zn) as compared to pure ZnO was obtained. The values of the reaction rate constants were found to be 0.0480 h−1 for ZnO, and 0.1072 h−1 for ZnO:MoO3, respectively.

1 November 2019 in Materials & Design
Verified
Journal Article
Open access
Petronela PascariuPetronela Pascariu
Petronela Pascariu
Dimitra VernardouDimitra Vernardou
Dimitra Vernardou
Mirela Petruta SucheaMirela Petruta Suchea
Mirela Petruta Suchea
AAAnton Airinei
Anton Airinei
LULaura Ursu
Laura Ursu
Emmanouel KoudoumasEmmanouel Koudoumas
Emmanouel Koudoumas

16 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Marian IonMarian Ion
Marian Ion
SDSilviu Dinulescu
Silviu Dinulescu
BFBogdan Firtat
Bogdan Firtat
MSMihaela Savin
Mihaela Savin
OIOctavian Narcis Ionescu
Octavian Narcis Ionescu
CMCarmen Moldovan
Carmen Moldovan
In recent years, research into the field of materials for flexible sensors and fabrication techniques directed towards wearable devices has helped to raise awareness of the need for new sensors with healthcare applicability. Our goal was to create a wearable flexible pressure sensor that could be integrated into a clinically approved blood pressure monitoring device. The sensor is built from a microfluidic channel encapsulated between two polymer layers, one layer being covered by metal transducers and the other being a flexible membrane containing the microfluidic channel, which also acts as a sealant for the structure. The applied external pressure deforms the channel, causing changes in resistance to the microfluidic layer. Electrical characterization has been performed in 5 different configurations, using alternating current (AC) and (DC) direct current measurements. The AC measurements for the fabricated pressure sensor resulted in impedance values at tens of hundreds of kOhm. Our sensor proved to have a high sensitivity for pressure values between 0 and 150 mm Hg, being subjected to repeatable external forces. The novelty presented in our work consists in the unique technological flow for the fabrication of the flexible wearable pressure sensor. The proposed miniaturized pressure sensor will ensure flexibility, low production cost and ease of use. It is made of very sensitive microfluidic elements and biocompatible materials and can be integrated into a wearable cuffless device for continuous blood pressure monitoring.