The stress corrosion cracking (SCC) growth rates of a cold-worked Type 316L (UNS S31603) stainless steel specimen in high-purity water at various temperatures were measured under various loading modes at a relatively low stress intensity factor (K) of 15 MPa·m0.5. A contoured double cantilever beam (CDCB) specimen was used for measuring the crack growth rates (CGR) under constant K conditions. An alternating current potential drop (ACPD) technique was used to monitor the crack growth kinetics throughout the test. The fracture surface shows typical intergranular SCC characteristics. Steady-state CGR values are used to quantify the effects of the loading mode and the environmental temperature. Different unloading/reloading procedures moderately increase the CGR, depending on the holding time and unloading/reloading periods. The crack growth rate increases with temperature in the temperature range between 200°C and 288°C. However, the observed apparent activation energies were different for different temperature ranges. The results show that multiple processes are involved in the stress corrosion crack growth. The effects due to changing the loading mode occurred quickly, while significant time-dependent crack-growth transition periods were observed after increasing or decreasing the test temperatures.
The properties of the oxide films formed on solution-annealed and cold-worked 316L stainless steel (SS) specimens with and without charged hydrogen in deaerated pressurized water reactor primary water at 300 °C were investigated. The outer oxide layers of all specimens were composed of magnetite (Fe3O4) and NiFe2O4. Charged hydrogen resulted in larger outer iron-bearing oxide particles forming due to hydrogen-enhanced outward diffusion of iron cations. Prior cold-work accelerates the oxidation was observed. Charged hydrogen led to local cracks in the oxide film and enhanced the penetration oxidation beneath the metal/oxide interface. The Cr-rich inner oxide layer grown on the prior cold-worked specimen with charged hydrogen was thicker than that on the cold-work specimen or the hydrogen-charged specimen, revealing the combined effects of charged hydrogen and prior cold-work on the acceleration of the oxidation process. The working mechanism of the solid-state hydrogen effect on the oxide film was discussed.