Weiting Liu

Dr. Weiting Liu

The State Key Laboratory of Fluid Power and Mechatronic Systems, Department of Mechanical Engineering, Zhejiang University, Hangzhou 310027, China

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 June 2016 in Sensors
Verified
Journal Article
Open access
PDF file
PYPing Yu
Ping Yu
WLWeiting Liu
Weiting Liu
CGChunxin Gu
Chunxin Gu
XCXiaoying Cheng
Xiaoying Cheng
FXFu Xin
Fu Xin
A new flexible piezoelectric tactile sensor array based on polyvinylidene fluoride (PVDF) film is proposed for measuring three-axis dynamic contact force distribution. The array consists of six tactile units arranged as a 3 × 2 matrix with spacing 8 mm between neighbor units. In each unit, a PVDF film is sandwiched between four square-shaped upper electrodes and one square-shaped lower electrode, forming four piezoelectric capacitors. A truncated pyramid bump is located above the four piezoelectric capacitors to improve force transmission. A three-axis contact force transmitted from the top of the bump will lead to the four piezoelectric capacitors underneath undergoing different charge changes, from which the normal and shear components of the force can be calculated. A series of dynamic tests have been carried out by exerting sinusoidal forces with amplitudes ranging from 0 to 0.5 N in the x-axis, 0 to 0.5 N in the y-axis, and 0 to 1.5 N in the z-axis, separately. The tactile units show good sensitivities with 14.93, 14.92, and 6.62 pC/N in the x-, y-, and z-axes, respectively. They can work with good linearity, relatively low coupling effect, high repeatability, and acceptable frequency response in the range of 5–400 Hz to both normal and shear load. In addition, dynamic three-axis force measurement has been conducted for all of the tactile units. The average errors between the applied and calculated forces are 10.68% ± 6.84%. Furthermore, the sensor array can be easily integrated onto a curved surface, such as robotic and prosthetic hands, due to its excellent flexibility.

26 January 2010 in Sensors
Verified
Journal Article
Open access
PDF file
FLFei Li
Fei Li
WLWeiting Liu
Weiting Liu
CSCesare Stefanini
Cesare Stefanini
FXFu Xin
Fu Xin
PDPaolo Dario
Paolo Dario
This paper describes the concept and design of a novel artificial hair receptor for the sensing system of micro intelligent robots such as a cricket-like jumping mini robot. The concept is inspired from the natural hair receptor of animals, also called cilium or filiform hair by different research groups, which is usually used as a vibration receptor or a flow detector by insects, mammals and fishes. The suspended fiber model is firstly built and the influence of scaling down is analyzed theoretically. The design of this artificial hair receptor is based on aligned suspended PVDF (polyvinylidene fluoride) fibers, manufactures with a novel method called thermo-direct drawing technique, and aligned suspended submicron diameter fibers are thus successfully fabricated on a flexible Kapton. In the post process step, some key problems such as separated electrodes deposition along with the fiber drawing direction and poling of micro/nano fibers to impart them with good piezoeffective activity have been presented. The preliminary validation experiments show that the artificial hair receptor has a reliable response with good sensibility to external pressure variation and, medium flow as well as its prospects in the application on sensing system of mini/micro bio-robots.

23 January 2019 in Journal of Materials Chemistry A
Verified
Journal Article
Closed access
PDF file
Yi-Ting LaiYi-Ting Lai
Yi-Ting Lai
WLWeiting Liu
Weiting Liu
CJChen L. J.
Chen L. J.
MCMin-Chao Chang
Min-Chao Chang
CLChiyoung Lee
Chiyoung Lee
NTNyan-Hwa Tai
Nyan-Hwa Tai
Phosphorus is a unique, limited, and a critical element in agriculture and industrial applications. However, in the absence of proper control, wastewater from industries may contain excessive phosphate, which causes eutrophication of lakes and rivers. Current research on the uptake and release of phosphate from wastewater is time-consuming and may produce a harmful effect on the environment. Herein, we developed an ultra-efficient process for the selective uptake and release of phosphate in wastewater based on graphene oxide (GO)/magnesium manganese-layered double hydroxide (LDH) composites calcined at 300 °C (GO/MgMn-LDH-300). In the proposed continuous electrosorption-desorption system, the adsorbed phosphate can be quickly released by controlling the applied voltage. The intercalated GO within the layered structure increases the surface area and generates more mesopores for phosphate adsorption. In addition, the abundant oxygen-containing functional groups on GO interact with metal ions, enhance Mn oxidation, and thereby produce more active sites for phosphate adsorption. The tunable applied potential difference controls the electrostatic interactions between the LDH composites and phosphate; the LDH composites show ultrahigh efficiency, excellent recyclability, and selective phosphate removal, and the phosphate adsorption and desorption rates of 0.79 and 3.56 mg P g−1 min−1, respectively, have been achieved. Via incorporating a single-voltage control process, the GO/MgMn-LDH-300 composite electrodes performed excellently in phosphate removal from wastewater and exhibited an outstanding desorption capacity; this showed potential of this process for commercial wastewater treatment.

11 January 2024 in Energy
Verified
Journal Article
Closed access
WLWeiting Liu
Weiting Liu
JWJ.K. Wu
J.K. Wu
MYM. Yu
M. Yu
XZX.J. Zhang
X.J. Zhang
TWT. Wang
T. Wang
LJLong Jiang
Long Jiang

26 January 2018 in Sensors
Verified
Journal Article
Open access
PDF file
WLWeiting Liu
Weiting Liu
CGChunxin Gu
Chunxin Gu
RZRuimin Zeng
Ruimin Zeng
PYPing Yu
Ping Yu
FXFu Xin
Fu Xin
High-density tactile sensing has been pursued for humanoid robotic hands to obtain contact force information while the elastomer skin cover is traditionally considered to impair the force discrimination. In this work, we try to utilize the diffusion effect of the elastomer cover to identify an arbitrary contact force load just based on a sparse tactile sensor array. By numerical analysis, we proved the monotonous relation between the Pearson’s correlation coefficient and the relative distance of two single-force loads. Then, we meshed the elastomer surface and conducted the calibration load process to establish the calibration database of the sensing outputs. Afterwards, we applied the correlation method to the database and the sensing output of the unknown load to determine its location and intensity. For validation tests of the proposed method, we designed and fabricated a 3 × 3 sparse tactile sensor array with flat elastomer cover and established an automatic three-axis loading system. The validation tests were implemented including 100 random points with force intensity ranging from 0.1 to 1 N. The test results show that the method has good accuracy of detecting force load with the mean location error of 0.46 mm and the mean intensity error of 0.043 N, which meets the basic requirements of tactile sensing. Therefore, it is feasible for the sparse tactile sensor array to realize high-density load detection.

14 August 2017 in Smart Materials and Structures
Verified
Journal Article
Closed access
PDF file
CGChunxin Gu
Chunxin Gu
WLWeiting Liu
Weiting Liu
PYPing Yu
Ping Yu
XCXiaoying Cheng
Xiaoying Cheng
XFXin Fu
Xin Fu
Current flexible/compliant tactile sensors suffer from low sensitivity and high hysteresis introduced by the essential viscosity characteristic of soft material, either used as compliant sensing element or as flexible coverage. To overcome these disadvantages, this paper focuses on developing a tactile sensor with a smart hybrid structure to obtain comprehensive properties in terms of size, compliance, robustness and pressure sensing ability so as to meet the requirements of limited space applications such as prosthetic fingertips. Employing micro-fabricated tiny silicon-based pressure die as the sensing element, it is easy to have both small size and good mechanical performance. To protect it from potential damage and maintain the compliant surface, a rigid base and a soft layer form a sealed chamber and encapsulate the fixed die together with fluid. The fluid serves as highly efficient pressure propagation media of mechanical stimulus from the compliant skin to the pressure die without any hazard impacting the vulnerable connecting wires. To understand the pressure transmission mechanism, a simplified and concise analytic model of a spring system is proposed. Using easy fabrication technologies, a prototype of a 3 × 3 sensor array with total dimensions of 14 mm × 14 mm × 6.5 mm was developed. Based on the quasi-linear relationship between fluid volume and pressure, finite element modeling was developed to analyze the chamber deformation and pressure output of the sensor cell. Experimental tests of the sensor prototype were implemented. The results showed that the sensor cell had good sensing performance with sensitivity of 19.9 mV N −1 , linearity of 0.998, repeatability error of 3.41%, and hysteresis error of 3.34%. The force sensing range was from 5 mN to 1.6 N.