A new flexible piezoelectric tactile sensor array based on polyvinylidene fluoride (PVDF) film is proposed for measuring three-axis dynamic contact force distribution. The array consists of six tactile units arranged as a 3 × 2 matrix with spacing 8 mm between neighbor units. In each unit, a PVDF film is sandwiched between four square-shaped upper electrodes and one square-shaped lower electrode, forming four piezoelectric capacitors. A truncated pyramid bump is located above the four piezoelectric capacitors to improve force transmission. A three-axis contact force transmitted from the top of the bump will lead to the four piezoelectric capacitors underneath undergoing different charge changes, from which the normal and shear components of the force can be calculated. A series of dynamic tests have been carried out by exerting sinusoidal forces with amplitudes ranging from 0 to 0.5 N in the x-axis, 0 to 0.5 N in the y-axis, and 0 to 1.5 N in the z-axis, separately. The tactile units show good sensitivities with 14.93, 14.92, and 6.62 pC/N in the x-, y-, and z-axes, respectively. They can work with good linearity, relatively low coupling effect, high repeatability, and acceptable frequency response in the range of 5–400 Hz to both normal and shear load. In addition, dynamic three-axis force measurement has been conducted for all of the tactile units. The average errors between the applied and calculated forces are 10.68% ± 6.84%. Furthermore, the sensor array can be easily integrated onto a curved surface, such as robotic and prosthetic hands, due to its excellent flexibility.
25 July 2020 in Structural and Multidisciplinary Optimization
This paper proposes a novel flexible tactile sensor array for dynamic triaxial force measurement. Piezoresistive nanofibers, which are fabricated via the electrospinning method and are composed of multi-wall carbon nanotubes (MWCNTs) and thermoplastic polyurethane (TPU), are selected as the sensing material. The sensitive piezoresistive layer, which has micron-scale thickness, is wrapped in polydimethylsiloxane (PDMS) with a bumped surface. This structure not only detects triaxial forces of different magnitudes and frequencies, but also can recognize the shape, size, and curvature of external objects using multiple measuring points of the sensor. When the sensor is subjected to normal forces at different frequencies, the measuring voltage shows good responses with variations of less than 1.21 %. When the sensor is subjected to shear forces, the coefficient of variation is less than 2.05%. In addition, when the sensor is stressed at multiple measuring points, the voltage response errors between the different points are less than 5.29%. The sensor shows high sensitivity (with a resistance change that can reach four orders of magnitude) and high response-speeds (response within 62 ms) in validation experiments. The proposed flexible sensor is efficient in triaxial force detection and has the potential for application to prosthetic hands and wearable devices.
In order to improve the fitting accuracy and optimization efficiency of the surrogate model, a multi-response weighted adaptive sampling (MWAS) approach based on the hybrid surrogate model was proposed and implemented to a multi-objective lightweight design of car seats. In this approach, the sample discreteness index in the input design space was calculated by the maximum and minimum distance approach (MDA), the fitting uncertainty index of output response was calculated by a strategy based on the weighted prediction variance (WPV), and the two indices are combined by the weight coefficients. In the iterative process, the weight coefficients of the two indices were determined according to the accuracy of the hybrid surrogate model. The balance of global and local accuracy was realized by considering the sample dispersion and the fitting uncertainty of the surrogate model comprehensively. Numerical examples of single-response and multi-response systems showed that the proposed approach has excellent sampling efficiency and robustness. Moreover, the results of actual engineering application showed that the hybrid surrogate model constructed through MWAS could significantly improve the efficiency of model optimization. Hence, a high-precision optimization solution to the multi-objective lightweight design of passenger car rear seat was obtained.
5 November 2019 in Journal of Chemical & Engineering Data
High-density tactile sensing has been pursued for humanoid robotic hands to obtain contact force information while the elastomer skin cover is traditionally considered to impair the force discrimination. In this work, we try to utilize the diffusion effect of the elastomer cover to identify an arbitrary contact force load just based on a sparse tactile sensor array. By numerical analysis, we proved the monotonous relation between the Pearson’s correlation coefficient and the relative distance of two single-force loads. Then, we meshed the elastomer surface and conducted the calibration load process to establish the calibration database of the sensing outputs. Afterwards, we applied the correlation method to the database and the sensing output of the unknown load to determine its location and intensity. For validation tests of the proposed method, we designed and fabricated a 3 × 3 sparse tactile sensor array with flat elastomer cover and established an automatic three-axis loading system. The validation tests were implemented including 100 random points with force intensity ranging from 0.1 to 1 N. The test results show that the method has good accuracy of detecting force load with the mean location error of 0.46 mm and the mean intensity error of 0.043 N, which meets the basic requirements of tactile sensing. Therefore, it is feasible for the sparse tactile sensor array to realize high-density load detection.