Fu Xin

Fu Xin


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 June 2016 in Sensors
Verified
Journal Article
Open access
PDF file
PYPing Yu
Ping Yu
WLWeiting Liu
Weiting Liu
CGChunxin Gu
Chunxin Gu
XCXiaoying Cheng
Xiaoying Cheng
FXFu Xin
Fu Xin
A new flexible piezoelectric tactile sensor array based on polyvinylidene fluoride (PVDF) film is proposed for measuring three-axis dynamic contact force distribution. The array consists of six tactile units arranged as a 3 × 2 matrix with spacing 8 mm between neighbor units. In each unit, a PVDF film is sandwiched between four square-shaped upper electrodes and one square-shaped lower electrode, forming four piezoelectric capacitors. A truncated pyramid bump is located above the four piezoelectric capacitors to improve force transmission. A three-axis contact force transmitted from the top of the bump will lead to the four piezoelectric capacitors underneath undergoing different charge changes, from which the normal and shear components of the force can be calculated. A series of dynamic tests have been carried out by exerting sinusoidal forces with amplitudes ranging from 0 to 0.5 N in the x-axis, 0 to 0.5 N in the y-axis, and 0 to 1.5 N in the z-axis, separately. The tactile units show good sensitivities with 14.93, 14.92, and 6.62 pC/N in the x-, y-, and z-axes, respectively. They can work with good linearity, relatively low coupling effect, high repeatability, and acceptable frequency response in the range of 5–400 Hz to both normal and shear load. In addition, dynamic three-axis force measurement has been conducted for all of the tactile units. The average errors between the applied and calculated forces are 10.68% ± 6.84%. Furthermore, the sensor array can be easily integrated onto a curved surface, such as robotic and prosthetic hands, due to its excellent flexibility.

26 January 2010 in Sensors
Verified
Journal Article
Open access
PDF file
FLFei Li
Fei Li
WLWeiting Liu
Weiting Liu
CSCesare Stefanini
Cesare Stefanini
FXFu Xin
Fu Xin
PDPaolo Dario
Paolo Dario
This paper describes the concept and design of a novel artificial hair receptor for the sensing system of micro intelligent robots such as a cricket-like jumping mini robot. The concept is inspired from the natural hair receptor of animals, also called cilium or filiform hair by different research groups, which is usually used as a vibration receptor or a flow detector by insects, mammals and fishes. The suspended fiber model is firstly built and the influence of scaling down is analyzed theoretically. The design of this artificial hair receptor is based on aligned suspended PVDF (polyvinylidene fluoride) fibers, manufactures with a novel method called thermo-direct drawing technique, and aligned suspended submicron diameter fibers are thus successfully fabricated on a flexible Kapton. In the post process step, some key problems such as separated electrodes deposition along with the fiber drawing direction and poling of micro/nano fibers to impart them with good piezoeffective activity have been presented. The preliminary validation experiments show that the artificial hair receptor has a reliable response with good sensibility to external pressure variation and, medium flow as well as its prospects in the application on sensing system of mini/micro bio-robots.

7 January 2018 in Sensors
Verified
Journal Article
Open access
PDF file
HSHui-Min Shen
Hui-Min Shen
Liang HuLiang Hu
Liang Hu
FXFu Xin
Fu Xin
With the extensive applications of biomagnetic signals derived from active biological tissue in both clinical diagnoses and human-computer-interaction, there is an increasing need for approachable weak biomagnetic sensing technology. The inherent merits of giant magnetoresistance (GMR) and its high integration with multiple technologies makes it possible to detect weak biomagnetic signals with micron-sized, non-cooled and low-cost sensors, considering that the magnetic field intensity attenuates rapidly with distance. This paper focuses on the state-of-art in integrated GMR technology for approachable biomagnetic sensing from the perspective of discipline fusion between them. The progress in integrated GMR to overcome the challenges in weak biomagnetic signal detection towards high resolution portable applications is addressed. The various strategies for 1/f noise reduction and sensitivity enhancement in integrated GMR technology for sub-pT biomagnetic signal recording are discussed. In this paper, we review the developments of integrated GMR technology for in vivo/vitro biomagnetic source imaging and demonstrate how integrated GMR can be utilized for biomagnetic field detection. Since the field sensitivity of integrated GMR technology is being pushed to fT/Hz0.5 with the focused efforts, it is believed that the potential of integrated GMR technology will make it preferred choice in weak biomagnetic signal detection in the future.

31 March 2011 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
ZXZhongbin Xu
Zhongbin Xu
CLChunhui Li
Chunhui Li
DVDamien Vadillo
Damien Vadillo
XRXiaodong Ruan
Xiaodong Ruan
FXFu Xin
Fu Xin

31 August 2011 in Microelectronic Engineering
Verified
Journal Article
Closed access
WLWeiting Liu
Weiting Liu
XCXiaoying Cheng
Xiaoying Cheng
FXFu Xin
Fu Xin
CSCesare Stefanini
Cesare Stefanini
PDPaolo Dario
Paolo Dario

1 January 2014 in Chinese Journal of Mechanical Engineering
Verified
Journal Article
Closed access
PDF file
ZLZhe Lin
Zhe Lin
XRXiaodong RUAN
Xiaodong RUAN
JZJun Zou
Jun Zou
FXFu Xin
Fu Xin
Cavitation of centrifugal blood pump is a serious problem accompany with the blocking failure of short inlet cannula. However, hardly any work has been seen in published literature on this complex cavitation phenomenon caused by the coupling effect of inlet cannula blocking and pumps suction. Even for cavitation studies on ordinary centrifugal pumps, similar researches on this issue are rare. In this paper, the roles of throttling, rotation speed and fluid viscosity on bubble inception and intensity in a centrifugal blood pump are studied, on the basis of experimental observations. An adjustable throttle valve installed just upstream blood pump inlet is used to simulate the throttling effect of the narrowed inlet cannula. The rotation speed is adjusted from 2 600 r/min to 3 200 r/min. Glycerin water solutions are used to investigate the influences of kinetic viscosity. Bubbles are recorded with a high-speed video camera. Direct observation shows that different from cavitation in industrial centrifugal pumps, gas nuclei appears at the nearby of vane leading edges while throttling is light, then moves upstream to the joint position of inlet pipe and pump with the closing of the valve. It’s found that the critical inlet pressure, obtained when bubbles are first observed, decreases linearly with viscosity and the slope is independent with rotation speeds; the critical inlet pressure and the inlet extreme pressure which is obtained when the throttle valve is nearly closed, fall linearly with rotation speed respectively and the relative pressure between them is independent with rotation speed and fluid viscosity. This paper studies experimentally on cavitation in centrifugal blood pump that caused by the failure of assembled short inlet cannula, which may beneficial the design of centrifugal blood pump with inlet cannula.