Yuzhen Xia

Dr. Yuzhen Xia

Zhejiang University of Science and Technology, Hangzhou, Zhejiang, China
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2022 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
YXYuzhen Xia
Yuzhen Xia
YHYiwei Hu
Yiwei Hu
Guilin HuGuilin Hu
Guilin Hu
HLHangwei Lei
Hangwei Lei
JLJiazhou Lu
Jiazhou Lu
QWQianpu Wang
Qianpu Wang

24 June 2024 in ACS Omega
Verified
Journal Article
Open access
CSChuanfu Sun
Chuanfu Sun
Guilin HuGuilin Hu
Guilin Hu
LCLili Cao
Lili Cao
TPTaijun Pan
Taijun Pan
CGChengfeng Guo
Chengfeng Guo
YXYuzhen Xia
Yuzhen Xia
Metal foam flow field suffers serious corrosion issues in proton exchange membrane fuel cells due to its large surface area. Ni and Ni/graphene coatings are prepared under constant and gradient current modes, respectively, to improve the corrosion resistance. The effect of the electrodeposition current mode and the deposition mechanism is studied. Compared with Ni coating, Ni/graphene coating brings low corrosion current density and high coating resistance, effectively enhancing the stability of Ni foam in an acidic environment. Different from Ni coating with a single layer, Ni/graphene deposits have core-shell structure, with graphene coated on the surface of Ni nanoparticles. It is shown that graphene deposits cover the Ni particles during the electrodeposition, which protects nickel particles from agglomeration and forms an inert film on the surface of the porous structure. After an 8 h constant potential test, no significant pitting is observed on the surface of Ni/graphene coating, showing excellent anticorrosion performance. As to the effect of the deposition current mode, it is shown that more composite particles deposit on the upper layer under the gradient current mode, which brings denser protective film and fewer surface defects on the surface. Ni/graphene coating electrodeposited under a gradient current mode between 0 and 10 mA·cm-2 exhibits the lowest corrosion current densities. The values at 50 and 80 °C are only 62.9 and 26.0% of those of uncoated Ni foam, respectively.

10 June 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
LCLingjiang Chen
Lingjiang Chen
ZWZichen Wang
Zichen Wang
CSChuanfu Sun
Chuanfu Sun
Guilin HuGuilin Hu
Guilin Hu
YXYuzhen Xia
Yuzhen Xia
Baizeng FangBaizeng Fang
Baizeng Fang
Porous metal foam with complex opening geometry has been used as a flow field to enhance the distribution of reactant gas and the removal of water in polymer electrolyte membrane fuel cells. In this study, the water management capacity of a metal foam flow field is experimentally investigated by polarization curve tests and electrochemical impedance spectroscopy measurements. Additionally, the dynamic behavior of water at the cathode and anode under various flooding situations is examined. It is found that obvious flooding phenomena are observed after water addition both into the anode and cathode, which are alleviated during a constant-potential test at 0.6 V. Greater abilities of anti-flooding and mass transfer and higher current densities are found as the same amount of water is added at the anode. No diffusion loop is depicted in the impedance plots although a 58.3% flow volume is occupied by water. The maximum current density of 1.0 A cm−2 and the lowest Rct around 17 mΩ cm2 are obtained at the optimum state after 40 and 50 min of operation as 2.0 and 2.5 g of water are added, respectively. The porous metal pores store a certain amount of water to humidify the membrane and achieve an internal “self-humidification” function.

11 January 2023 in Energies
Verified
Journal Article
Open access
PDF file
YXYuzhen Xia
Yuzhen Xia
HLHangwei Lei
Hangwei Lei
XWXiaojun Wu
Xiaojun Wu
Guilin HuGuilin Hu
Guilin Hu
HPHao Pan
Hao Pan
Baizeng FangBaizeng Fang
Baizeng Fang
A comprehensive test system for proton exchange membrane fuel cells (PEMFCs) is designed and developed for monitoring and controlling the inlet and outlet parameters and safety issues of fuel cells. The data acquisition and output instruction rely on the connection between PLC (programmable logic controller) and OPC (object linking and embedding for process control). Based on Siemens S7-200 series PLC and PID (proportion integration differentiation) technology, the margin of error in relative humidity of inlet air is controlled at less than 0.7%. Furthermore, a hydrogen recycling system and an alarm module are introduced, considering the hydrogen or nitrogen solenoid valve power failure, cooling fan power failure, temperature anomaly, and hydrogen leakage. This developed test system is evaluated by the experimental investigation of PEMFC performance. The results show that the test system has very good test and control performances. At a cell temperature of 40 °C, enhanced performance in the polarization tests is depicted at a high humidification temperature of 60 °C.

14 November 2024 in Inorganics
Verified
Journal Article
Open access
PDF file
YXYuzhen Xia
Yuzhen Xia
启左启斌 左
启斌 左
CSChuanfu Sun
Chuanfu Sun
Guilin HuGuilin Hu
Guilin Hu
Baizeng FangBaizeng Fang
Baizeng Fang
Metal foams are promising materials for the flow fields of proton exchange membrane fuel cells (PEMFCs) because of excellent mass transport characteristics and high electronic conductivity. To resolve the corrosion problem in the acidic environment under high temperature, nickel/graphene (Ni/G) composite coatings with hierarchical structures were electrodeposited on the surface of Ni foam. The effect of grain size and the distribution in the double layer was discussed. It was found that Ni/G5-10, with larger inner size and middle outer size, exhibited the best corrosion performance. Meanwhile, the corrosion current in the Tafel plots and the steady current density in constant potential analysis was lower than that obtained under steady and gradient currents. Combined with the results of XRD, XPS, and SEM, it was proven that a uniform and dense protective film was produced during the two-step electrodeposition. Moreover, the ICR value was 8.820 mΩ·cm2, which met the requirement of 2025 DOE.

26 October 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
YXYuzhen Xia
Yuzhen Xia
HLHangwei Lei
Hangwei Lei
CSChuanfu Sun
Chuanfu Sun
XWXiaohao Wen
Xiaohao Wen
ZWZichen Wang
Zichen Wang
Baizeng FangBaizeng Fang
Baizeng Fang
Chemical functionalization of carbon support for Pt catalysts is a promising way to enhance the performance of catalysts. In this study, Pt/C catalysts grafted with various amounts of phenylsulfonic acid groups were prepared under mild conditions. The influence of sulfonic acid groups on the physiochemical characteristics and electrochemical activities of the modified catalysts were studied using X-ray diffraction, X-ray photoelectron spectroscopy, a transmission electron microscope, and cyclic voltammetry (CV). The presence of the chemical groups enhanced the hydrogen adsorption onto/desorption off the Pt surface during the CV cycling. In contrast, the hydrogen peaks of the grafted catalysts increased after 500 CV cycles, especially for Pt (111) facets. The highest electrochemical surface area (ECSA) after the aging test was obtained for the catalyst with 18.0 wt.% graft, which was ca. 87.3% higher than that of the non-functionalized Pt catalyst. In the density functional theory (DFT) calculation, it was proven that SO3H adsorption on the crystalline was beneficial for Pt stability. The adsorption energy and bond distance of the adsorbed SO3H on Pt (110), (100), and (111) surfaces were calculated. All the stable configurations were obtained when O from S-O single bond or S was bound to the Pt surface, with the adsorption energy following the trend of (111)F > (100)H > (110)H. This result was consistent with the ECSA experiment, which explained the high electrochemical stability of the sulfonic acid groups-grafted Pt/C catalyst.