Jarosław Michalak

Dr. Jarosław Michalak

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 December 2021 in Energies
Verified
Journal Article
Open access
PDF file
Dawid BułaDawid Buła
Dawid Buła
GJGrzegorz Jarek
Grzegorz Jarek
JMJarosław Michalak
Jarosław Michalak
MZMarcin Zygmanowski
Marcin Zygmanowski
An active power filter based on a three-level neutral point clamped T-type converter with LCL input filter is presented in the paper. The main goal of the paper is the analysis of a control system that ensures independent control of a current in each phase. The presented control method of the filter allows reactive power compensation and/or a higher harmonics reduction to be achieved in each phase independently, with the possibility of control tan (φ) coefficient. This allows the power flow between the phases to be minimalized and reduces the RMS values of filter currents without the need to balance grid currents. The analysis presents the possibility of an operation in different modes, which was verified by experimental results. The results have been obtained in a 20 ARMS laboratory system described in the paper. The results reveal relatively low power losses, which are a feature of the selected three-level T-type topology. Additionally, that topology, when compared to a two-level one, ensures the reduction in current ripples with the same parameters of passive components.

28 March 2019 in Electronics
Verified
Journal Article
Open access
PDF file
Krzysztof BernackiKrzysztof Bernacki
Krzysztof Bernacki
DWDominik Wybrańczyk
Dominik Wybrańczyk
MZMarcin Zygmanowski
Marcin Zygmanowski
ALAndrzej Latko
Andrzej Latko
JMJarosław Michalak
Jarosław Michalak
Zbigniew Andrzej RymarskiZbigniew Andrzej Rymarski
Zbigniew Andrzej Rymarski
Today, to use home automation, intelligent home controls or remote controls in the office, electronic equipment is moving away from wireless communication in favor of Power Line Communication (PLC). In the standard PLC solutions, the corrections that result from error transmissions are based on complex digital modulation methods and algorithms for validating the transmitted data without paying attention to the causes of the errors. This article focuses on the implementation of a filtering system for interference and signals in the 120–150 kHz band (CENELEC band C), which is injected into the network by transmitters. Such a filter separates the desired signal from the interference that is occurring in the network, which can result in communication errors. Moreover, when used properly, the filter can be used as a subsystem separation element. The paper presents the requirements, design, construction, simulation and test results that were obtained under actual operating conditions. It is possible to use less complex methods for correcting errors in transmission signals and to guarantee an improvement in the transmission rate using the proposed filter system.

11 August 2021 in Energies
Verified
Journal Article
Open access
PDF file
TBTadeusz Białoń
Tadeusz Białoń
RNRoman Niestrój
Roman Niestrój
JMJarosław Michalak
Jarosław Michalak
MPMarian Pasko
Marian Pasko
This article presents an innovative induction motor state observer designed to reconstruct magnetic fluxes and the angular speed of an induction motor for speed sensorless control system applications such as field-oriented control (FOC). This observer is an intermediate solution between the proportional observer and the classical proportional-integral (PI) observer with respect to which the order of the integrating unit is reduced. Additional modifications of the observer’s structure have been implemented to ensure stability and to improve its functional properties. As a result, two versions of the observer structure were produced and experimentally tested using a sensorless FOC control system. Both structures resulted in correct control system operation for a wide range of angular speeds, including low speed ranges.

1 September 2013
Verified
Conference Paper
Closed access
MZMarcin Zygmanowski
Marcin Zygmanowski
JMJarosław Michalak
Jarosław Michalak
BGBoguslaw Grzesik
Boguslaw Grzesik
The paper presents the dc-link voltage balancing method for a five-level hybrid asymmetric multilevel converter based on a neutral point clamped (NPC) converter with H-bridge (HB) converters. The considered converter, which is referred to as NPC-HB, is treated in this paper as a modification of the classic three-level NPC converter. It improves the harmonic performance of output voltage compared to the NPC converter. This improvement is made by increasing the number of levels in the converter output voltage. Nevertheless, due to the use of floating H-bridge converters inside the NPC-HB topology, the dc voltage balancing method is implemented. Basing on the converter ac side current and HB converter dc link voltage, the proposed method modifies the PWM modulation scheme in both NPC and HB converters. This modification is applied to each switching period while the converter output voltage reference is kept unchanged. Such modulation scheme is characterized as robust and guaranteeing the low harmonic content in the output voltage. Other dc voltage balancing methods of the hybrid NPC-HB converter are compared in this paper. The proposed method is experimentally verified.

14 August 2021 in Energies
Verified
Journal Article
Open access
PDF file
Dawid BułaDawid Buła
Dawid Buła
JMJarosław Michalak
Jarosław Michalak
MZMarcin Zygmanowski
Marcin Zygmanowski
Tomasz AdrikowskiTomasz Adrikowski
Tomasz Adrikowski
GJGrzegorz Jarek
Grzegorz Jarek
MJMichał Jeleń
Michał Jeleń
The paper presents a shunt hybrid active power filter for 1 kV mining applications in configuration with a single-tuned passive filter. The focus is on the method of controlling the filter, with particular emphasis on the influence of network voltage distortion and time delays in control on the effectiveness of harmonic reduction, which is one of the most important aspect of power quality. The low-power loss configuration of a hybrid filter with SiC transistors is shown, as well as the control algorithm which limits the influence of voltage distortion. Theoretical considerations are verified by results obtained from simulations and tests of the hybrid active power filter prototype.

1 January 2005
Verified
Conference Paper
Closed access
SPS. Pasko
S. Pasko
TBT. Biskup
T. Biskup
CBC. Buehrer
C. Buehrer
BGB. Grzesik
B. Grzesik
JRJ. Roest-Krijgsman
J. Roest-Krijgsman
MZMarcin Zygmanowski
Marcin Zygmanowski
The selection of the less expensive power conditioning system (PCS) is the aim of the work where two types of PCS are taken into consideration. The first type of PCS is based on superconducting magnetic energy storage (SMES) while the second one is based on supercapacitor energy storage (ScES). The comparison is based on installed power as the criterion. An illustrative example is given in the work