Paweł Cichocki

Dr. Paweł Cichocki

Medical University of Lodz
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 July 2015 in Nuclear Medicine Review
Verified
Journal Article
Open access
PDF file
KKKatarzyna Kovacević-Kuśmierek
Katarzyna Kovacević-Kuśmierek
JKJózef Kozak
Józef Kozak
ŁPŁukasz Pryt
Łukasz Pryt
MBMałgorzata Bieńkiewicz
Małgorzata Bieńkiewicz
Paweł CichockiPaweł Cichocki
Paweł Cichocki
APAnna Płachcińska
Anna Płachcińska
BACKGROUND: Accurate prediction of postoperative pulmonary function in patients with non-small cell lung cancer is crucial for proper qualification for surgery, the only effective therapeutic method. The aim of the study was to select the most accurate method for acquisition and processing of lung perfusion scintigraphy (LPS) combined with spirometry for prediction of postoperative pulmonary function in patients qualified for surgery. MATERIAL AND METHODS: LPS was performed in 70 patients (40 males, 30 females), with preoperative spirometry (mean FEV1preop = 2.26 ± 0.72 L), after administration of 185 MBq of 99mTc-microalbumin/macroaggregate, using planar (appa) and SPECT/CT methods. Predicted postoperative lung function (FEV1pred) was calculated as a part of active lung parenchyma to remain after surgery. A non-imaging segment counting method was also applied. FEV1pred(appa, SPECT, SPECT/CT, segm.) were further compared with actual FEV1postop values obtained from postoperative spirometry. RESULTS: In the whole studied group (47 lobectomies, 23 pneumonectomies) mean value of FEV1postop was equal to 1.76 (± 0.56) L. FEV1pred(appa, SPECT, SPECT/CT, segm.) were equal to 1.75 (± 0.58) L, 1.71 (± 0.57) L, 1.72 (± 0.57) L and 1.57 (± 0.58) L, respectively. A segment counting method systematically lowered predicted FEV1 values (p < 10–5). Moreover, in 31 patients with FEV1preop < 2 L error of predicted values was assessed with Bland-Altman method. Mean absolute differences FEV1postop – FEV1pred amounted to: appa — (0.04 ± 0.13) L, SPECT — (0.07 ± 0.14) L, SPECT/CT — (0.06 ± 0.14) L and segm. — (0.21 ± 0.19) L, respectively. Lower limit of 95% confidence interval calculated for planar — optimal method, was equal to –220 mL (also determined separately in subgroups after lobectomy and pneumonectomy). CONCLUSIONS: This study shows that planar LPS may be applied for prediction of postoperative pulmonary function in patients qualified for pneumonectomy and lobectomy. If actual FEV1postop value is to be ≥ 800 mL, predicted value should exceed 1000 mL. BACKGROUND: Accurate prediction of postoperative pulmonary function in patients with non-small cell lung cancer is crucial for proper qualification for surgery, the only effective therapeutic method. The aim of the study was to select the most accurate method for acquisition and processing of lung perfusion scintigraphy (LPS) combined with spirometry for prediction of postoperative pulmonary function in patients qualified for surgery. MATERIAL AND METHODS: LPS was performed in 70 patients (40 males, 30 females), with preoperative spirometry (mean FEV1preop = 2.26 ± 0.72 L), after administration of 185 MBq of 99mTc-microalbumin/macroaggregate, using planar (appa) and SPECT/CT methods. Predicted postoperative lung function (FEV1pred) was calculated as a part of active lung parenchyma to remain after surgery. A non-imaging segment counting method was also applied. FEV1pred(appa, SPECT, SPECT/CT, segm.) were further compared with actual FEV1postop values obtained from postoperative spirometry. RESULTS: In the whole studied group (47 lobectomies, 23 pneumonectomies) mean value of FEV1postop was equal to 1.76 (± 0.56) L. FEV1pred(appa, SPECT, SPECT/CT, segm.) were equal to 1.75 (± 0.58) L, 1.71 (± 0.57) L, 1.72 (± 0.57) L and 1.57 (± 0.58) L, respectively. A segment counting method systematically lowered predicted FEV1 values (p < 10–5). Moreover, in 31 patients with FEV1preop < 2 L error of predicted values was assessed with Bland-Altman method. Mean absolute differences FEV1postop – FEV1pred amounted to: appa — (0.04 ± 0.13) L, SPECT — (0.07 ± 0.14) L, SPECT/CT — (0.06 ± 0.14) L and segm. — (0.21 ± 0.19) L, respectively. Lower limit of 95% confidence interval calculated for planar — optimal method, was equal to –220 mL (also determined separately in subgroups after lobectomy and pneumonectomy). CONCLUSIONS: This study shows that planar LPS may be applied for prediction of postoperative pulmonary function in patients qualified for pneumonectomy and lobectomy. If actual FEV1postop value is to be ≥ 800 mL, predicted value should exceed 1000 mL.

Verified
Journal Article
Open access
PDF file
Paweł CichockiPaweł Cichocki
Paweł Cichocki
MBMichał Błaszczyk
Michał Błaszczyk
KCKamila Cygulska
Kamila Cygulska
KFKrzysztof Filipczak
Krzysztof Filipczak
ZAZbigniew Adamczewski
Zbigniew Adamczewski
APAnna Płachcińska
Anna Płachcińska
Background: Myocardial blood flow (MBF) and flow reserve (MFR) examination, especially useful in the diagnosis of multivessel coronary artery disease (CAD), can be assessed with a cadmium-zinc-telluride (CZT) SPECT gamma camera, as an alternative to the expensive and less available PET. However, study processing is not free from subjective factors. Therefore, this paper aims to evaluate intra- and interobserver repeatability of MBF and MFR values obtained by the same operator and two independent operators. Methods: This study included 57 adult patients. MBF and MFR were assessed using a Discovery NM530c camera in a two-day, rest/dipyridamople protocol, using 99mTc-MIBI. Data were processed using Corridor4DM software, twice by one operator and once by another operator. Results: The repeatability of the assessed values was quite good in the whole myocardium, LAD and LCX vascular territories, but was poor in the RCA territory. Conclusions: The poor repeatability of MBF and MFR in RCA vascular territory can be explained by poor automatic orientation of the heart axis during post-processing and a so-called “cardiac creep” phenomenon. Better automatic heart orientation and introduction of automatic motion correction is likely to drastically improve this repeatability. In the present state of the software, PET is better for patients requiring assessment of MFR in the RCA territory.

19 July 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Paweł CichockiPaweł Cichocki
Paweł Cichocki
APAnna Plachcinska
Anna Plachcinska
MBMichal Blaszczyk
Michal Blaszczyk
ZAZbigniew Adamczewski
Zbigniew Adamczewski
Dynamic assessment of myocardial blood flow (MBF) and myocardial flow reserve (MFR) provides additional information that can improve diagnostic accuracy of radionuclide myocardial perfusion imaging in some clinical situations. This study assessed processing repeatability of these parameters calculated using two models—net retention (RET) and one compartment (1CM) in dynamic SPECT studies, using the latest version of Corridor 4DM software (v2024). Data of 107 patients were analyzed retrospectively (57 of whom were assessed in our previous study using 4DM v2015). Dynamic SPECT studies were carried out using a routine two-day rest-dipyridamole protocol. Data was processed in 4DM v2024 twice by one operator and once by another operator. Automatic heart image positioning during post-processing in 4DM v2024 was significantly improved compared to v2015, reducing the number of studies requiring extensive manual corrections from 41 to 12%. This significantly improved interobserver processing repeatability of MFR values in RCA territory compared to our previous study using v2015—from r = 0.67 to 0.85 (p = 0.0034). Interobserver processing repeatability of MBF and MFR in all 107 patients was significantly better in RET model compared to 1CM model. In conclusion, RET model is more reliable for calculating MBF and MFR values based on dynamic SPECT studies.

6 August 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
Paweł CichockiPaweł Cichocki
Paweł Cichocki
ZAZbigniew Adamczewski
Zbigniew Adamczewski
JKJacek Kuśmierek
Jacek Kuśmierek
APAnna Płachcińska
Anna Płachcińska
A 61-year-old man was referred for myocardial perfusion scintigraphy (MPS) by an occupational physician to exclude coronary artery disease (CAD). The patient had a complete left bundle branch block (LBBB) that rendered the routine exercise stress test non-diagnostic, but otherwise had no history of heart diseases, good stress tolerance with no symptoms of angina, and no abnormalities in transthoracic echocardiogram, apart from contraction patterns typical for LBBB. Initial MPS, performed using technetium-labeled Sestamibi on a Discovery NM 530c camera equipped with solid-state semiconductor detectors, revealed a significant stress-induced ischemia that did not match the good overall condition of the patient. A motion detection procedure revealed significant heart motion in Z-axis during the stress study. Upon inquiry, the patient reported breathing difficulties caused by the mandatory mask, which slipped into an uncomfortable position during the study. Repeated acquisition, without motion artifacts, revealed no features of ischemia.

29 January 2015 in Nuclear Medicine Review
Verified
Journal Article
Open access
PDF file
Paweł CichockiPaweł Cichocki
Paweł Cichocki
MSMarian Surma
Marian Surma
WWWojciech Woźnicki
Wojciech Woźnicki
MBMałgorzata Bieńkiewicz
Małgorzata Bieńkiewicz
APAnna Płachcińska
Anna Płachcińska
JKJacek Kuśmierek
Jacek Kuśmierek
BACKGROUND: The clinical significance of MTT and PTT, determined by deconvolution of renographic curves, is arguable. Their usefulness in diagnosis of obstructive uro- and nephropathy, renovascular hypertension and monitoring of transplanted kidneys is pointed out, but susceptibility of deconvolution methods to errors resulting from “statistical noise” is also stressed. So far there are no reports on normative MTT values for 99mTc-EC, although such values were already determined for 131I-OIH, 99mTc-DTPA and 99mTc-MAG3. The aim of this study is an assessment of inter- and intraobserver reproducibility of MTT and PTT for 99mTc-EC, and determination of normative values for these parameters. MATERIALS AND METHODS: 31 patients (17 women and 14 men aged 19–75, average 44 years) referred for dynamic renal scintigraphy with: unilateral flow impairment (11), unilateral nephrolithiasis (2), control after unilateral lithotripsy (4), moderate hypertension (demographically with > 99% probability of primary hypertension) (4), suspected cirrhosis of one kidney (3), future kidney donors (3), control after abdominal injuries (3), incontinence (1). 42 functionally efficient kidneys were included in the study. Criteria for recognition of a kidney as functionally efficient were: — no earlier history of renal disease, signs of renal damage in basic blood and urine tests, or abnormalities in ultrasonography; — normal result of dynamic renal scintigraphy (in terms of sequential images and renographic curve). MTT and PTT values were determined independently by two operators, using a matrix method for deconvolution of renographic curves. RESULTS: Differences between mean MTT and PTT from two studies by one operator were insignificant and those values were closely correlated (r = 0.99 and r = 0.97, respectively). Differences of values obtained by both operators were practically insignificant for MTT (r = 0.93), and significant for PTT (r = 0.81 and p < 0.001). These differences do not disqualify that processing method. The upper limits of normative values of MTT and PTT were based on the results from first study performed by more experienced operator — 200 s and 170 s, respectively. CONCLUSIONS: The procedure of processing dynamic renal scintigraphy used in this study is reproducible. Normative values of MTT and PTT for 99mTc-EC were established as 200 s and 170 s, respectively. An attempt to optimize and standardize the technique of determining parenchymal ROI in a matrix deconvolution method, followed by an evaluation of clinical usefulness of these parameters in the diagnosis of chosen renal function impairments would be a logical continuation of this initial research. BACKGROUND: The clinical significance of MTT and PTT, determined by deconvolution of renographic curves, is arguable. Their usefulness in diagnosis of obstructive uro- and nephropathy, renovascular hypertension and monitoring of transplanted kidneys is pointed out, but susceptibility of deconvolution methods to errors resulting from “statistical noise” is also stressed. So far there are no reports on normative MTT values for 99mTc-EC, although such values were already determined for 131I-OIH, 99mTc-DTPA and 99mTc-MAG3. The aim of this study is an assessment of inter- and intraobserver reproducibility of MTT and PTT for 99mTc-EC, and determination of normative values for these parameters. MATERIALS AND METHODS: 31 patients (17 women and 14 men aged 19–75, average 44 years) referred for dynamic renal scintigraphy with: unilateral flow impairment (11), unilateral nephrolithiasis (2), control after unilateral lithotripsy (4), moderate hypertension (demographically with > 99% probability of primary hypertension) (4), suspected cirrhosis of one kidney (3), future kidney donors (3), control after abdominal injuries (3), incontinence (1). 42 functionally efficient kidneys were included in the study. Criteria for recognition of a kidney as functionally efficient were: — no earlier history of renal disease, signs of renal damage in basic blood and urine tests, or abnormalities in ultrasonography; — normal result of dynamic renal scintigraphy (in terms of sequential images and renographic curve). MTT and PTT values were determined independently by two operators, using a matrix method for deconvolution of renographic curves. RESULTS: Differences between mean MTT and PTT from two studies by one operator were insignificant and those values were closely correlated (r = 0.99 and r = 0.97, respectively). Differences of values obtained by both operators were practically insignificant for MTT (r = 0.93), and significant for PTT (r = 0.81 and p < 0.001). These differences do not disqualify that processing method. The upper limits of normative values of MTT and PTT were based on the results from first study performed by more experienced operator — 200 s and 170 s, respectively. CONCLUSIONS: The procedure of processing dynamic renal scintigraphy used in this study is reproducible. Normative values of MTT and PTT for 99mTc-EC were established as 200 s and 170 s, respectively. An attempt to optimize and standardize the technique of determining parenchymal ROI in a matrix deconvolution method, followed by an evaluation of clinical usefulness of these parameters in the diagnosis of chosen renal function impairments would be a logical continuation of this initial research.

27 November 2023 in Polish Archives of Internal Medicine
Verified
Journal Article
Closed access
AAAleksandra Aulich
Aleksandra Aulich
Paweł CichockiPaweł Cichocki
Paweł Cichocki
BSBorys Stefański
Borys Stefański
ZAZbigniew Adamczewski
Zbigniew Adamczewski
DOI: 10.20452/pamw.16616, Published online: November 27, 2023, Authors: Aleksandra Aulich, Paweł Cichocki, Borys Stefański , Zbigniew Adamczewski