Anna Płachcińska

Dr. Anna Płachcińska

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
Paweł CichockiPaweł Cichocki
Paweł Cichocki
MBMichał Błaszczyk
Michał Błaszczyk
KCKamila Cygulska
Kamila Cygulska
KFKrzysztof Filipczak
Krzysztof Filipczak
ZAZbigniew Adamczewski
Zbigniew Adamczewski
APAnna Płachcińska
Anna Płachcińska
Background: Myocardial blood flow (MBF) and flow reserve (MFR) examination, especially useful in the diagnosis of multivessel coronary artery disease (CAD), can be assessed with a cadmium-zinc-telluride (CZT) SPECT gamma camera, as an alternative to the expensive and less available PET. However, study processing is not free from subjective factors. Therefore, this paper aims to evaluate intra- and interobserver repeatability of MBF and MFR values obtained by the same operator and two independent operators. Methods: This study included 57 adult patients. MBF and MFR were assessed using a Discovery NM530c camera in a two-day, rest/dipyridamople protocol, using 99mTc-MIBI. Data were processed using Corridor4DM software, twice by one operator and once by another operator. Results: The repeatability of the assessed values was quite good in the whole myocardium, LAD and LCX vascular territories, but was poor in the RCA territory. Conclusions: The poor repeatability of MBF and MFR in RCA vascular territory can be explained by poor automatic orientation of the heart axis during post-processing and a so-called “cardiac creep” phenomenon. Better automatic heart orientation and introduction of automatic motion correction is likely to drastically improve this repeatability. In the present state of the software, PET is better for patients requiring assessment of MFR in the RCA territory.

6 August 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
Paweł CichockiPaweł Cichocki
Paweł Cichocki
ZAZbigniew Adamczewski
Zbigniew Adamczewski
JKJacek Kuśmierek
Jacek Kuśmierek
APAnna Płachcińska
Anna Płachcińska
A 61-year-old man was referred for myocardial perfusion scintigraphy (MPS) by an occupational physician to exclude coronary artery disease (CAD). The patient had a complete left bundle branch block (LBBB) that rendered the routine exercise stress test non-diagnostic, but otherwise had no history of heart diseases, good stress tolerance with no symptoms of angina, and no abnormalities in transthoracic echocardiogram, apart from contraction patterns typical for LBBB. Initial MPS, performed using technetium-labeled Sestamibi on a Discovery NM 530c camera equipped with solid-state semiconductor detectors, revealed a significant stress-induced ischemia that did not match the good overall condition of the patient. A motion detection procedure revealed significant heart motion in Z-axis during the stress study. Upon inquiry, the patient reported breathing difficulties caused by the mandatory mask, which slipped into an uncomfortable position during the study. Repeated acquisition, without motion artifacts, revealed no features of ischemia.

17 November 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
MBMichał Błaszczyk
Michał Błaszczyk
ZAZbigniew Adamczewski
Zbigniew Adamczewski
APAnna Płachcińska
Anna Płachcińska
This paper presents a review of the literature concerning the clinical application of modern semiconductor (CZT) gamma cameras in the radioinuclide diagnosis of coronary artery disease. It contains information on the diagnostic efficacy of myocardial perfusion studies performed with those cameras compared with the widely used scintillation (Anger) cameras, an overview of their effectiveness in comparison with coronary angiography (also fractional flow reserve) and currently available clinical results of a myocardial flow reserve measured with a dynamic SPECT study. Introduction of this imaging modality to the measurement of a myocardial flow reserve aims to facilitate access to this type of study compared to the less available and more expensive PET method used so far.

31 January 2017 in Nuclear Medicine Review
Verified
Journal Article
Open access
PDF file
KFKrzysztof Filipczak
Krzysztof Filipczak
JKJacek Kuśmierek
Jacek Kuśmierek
JDJaroslaw Drozdz
Jaroslaw Drozdz
KCKrzysztof Chiżyński
Krzysztof Chiżyński
Jaroslaw Damian KasprzakJaroslaw Damian Kasprzak
Jaroslaw Damian Kasprzak
APAnna Płachcińska
Anna Płachcińska
BACKGROUND: The work compares the results of shortened gated myocardial perfusion imaging (MPI), processed with „Myovation Evolution” software, with a study performed in a standard way. MATERIAL AND METHODS: A retrospective study was conducted in a group of 95 patients (56 males and 39 females, age 62 ± 9 years, BMI 28 ± 4) with known or suspected CAD, without clinical history or any signs of a previous myocardial infarction. All patients underwent coronary angiography (CA) within 3 months of MPI. CA was used as a reference for diagnostic performance of MPI. Patients underwent a stress/rest 2-day MPI. Both studies were performed twice, with normal (25s) and shortened (13s) time per projection. Studies were processed using Myovation protocol (OSEM with 2 iterations and 10 subsets) for full time (FT) studies and a Myovation Evolution protocol dedicated to half time (HT) studies (OSEM with 12 iterations, 10 subsets). Reconstructed images, with and without attenuation correction (AC), were evaluated by 2 experienced nuclear medicine specialists (a consensus), with regard to image quality and perfusion, evaluated using a visual semi-quantitative method, applying a standard division of myocardium into 17 segments. Perfusion was assessed in every segment using a standard 5 grade scale. Summed stress scores were calculated for every patient and threshold values for detection of CAD were selected based on ROC analysis with CA treated as a reference method. After 2 months FT images were interpreted again by the same specialists. RESULTS: The quality of images obtained from shortened and normal studies was equally good. All correlation coefficients between segmental scorings of FT and HT studies were high and statistically significant. Correlation coefficients between corresponding segments in FTAC and HTAC (i.e. with AC) studies were systematically higher than without AC. The agreement between FT and HT study results was equal to 81% for FT and HT studies and to 86% for FTAC and HTAC studies (p = 0.40). The repeatability of FTAC study assessments was equal to 94%. 95-percent confidence intervals calculated for agreement between FTAC and HTAC studies and the repeatability of FTAC study overlapped considerably. Correlation coefficients for EDV, ESV and EF values between FT and HT were high: 0.93, 0.96 and 0.88, respectively. CONCLUSION: Myovation Evolution protocol used for reconstruction of myocardial perfusion studies with reduced number of counts requires AC. The agreement between the results of visual assessment of normal and reduced count studies is high and not worse than the agreement between repeat assessment of a full time study. BACKGROUND: The work compares the results of shortened gated myocardial perfusion imaging (MPI), processed with „Myovation Evolution” software, with a study performed in a standard way. MATERIAL AND METHODS: A retrospective study was conducted in a group of 95 patients (56 males and 39 females, age 62 ± 9 years, BMI 28 ± 4) with known or suspected CAD, without clinical history or any signs of a previous myocardial infarction. All patients underwent coronary angiography (CA) within 3 months of MPI. CA was used as a reference for diagnostic performance of MPI. Patients underwent a stress/rest 2-day MPI. Both studies were performed twice, with normal (25s) and shortened (13s) time per projection. Studies were processed using Myovation protocol (OSEM with 2 iterations and 10 subsets) for full time (FT) studies and a Myovation Evolution protocol dedicated to half time (HT) studies (OSEM with 12 iterations, 10 subsets). Reconstructed images, with and without attenuation correction (AC), were evaluated by 2 experienced nuclear medicine specialists (a consensus), with regard to image quality and perfusion, evaluated using a visual semi-quantitative method, applying a standard division of myocardium into 17 segments. Perfusion was assessed in every segment using a standard 5 grade scale. Summed stress scores were calculated for every patient and threshold values for detection of CAD were selected based on ROC analysis with CA treated as a reference method. After 2 months FT images were interpreted again by the same specialists. RESULTS: The quality of images obtained from shortened and normal studies was equally good. All correlation coefficients between segmental scorings of FT and HT studies were high and statistically significant. Correlation coefficients between corresponding segments in FTAC and HTAC (i.e. with AC) studies were systematically higher than without AC. The agreement between FT and HT study results was equal to 81% for FT and HT studies and to 86% for FTAC and HTAC studies (p = 0.40). The repeatability of FTAC study assessments was equal to 94%. 95-percent confidence intervals calculated for agreement between FTAC and HTAC studies and the repeatability of FTAC study overlapped considerably. Correlation coefficients for EDV, ESV and EF values between FT and HT were high: 0.93, 0.96 and 0.88, respectively. CONCLUSION: Myovation Evolution protocol used for reconstruction of myocardial perfusion studies with reduced number of counts requires AC. The agreement between the results of visual assessment of normal and reduced count studies is high and not worse than the agreement between repeat assessment of a full time study.

2 February 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Paweł CichockiPaweł Cichocki
Paweł Cichocki
KFKrzysztof Filipczak
Krzysztof Filipczak
ZAZbigniew Adamczewski
Zbigniew Adamczewski
JKJacek Kuśmierek
Jacek Kuśmierek
APAnna Płachcińska
Anna Płachcińska
This study evaluates the usefulness of parameters allowing assessment of renal function in absolute values in dynamic renal scintigraphy (DRS) with 99mTc-ethylenedicysteine (99mTc-EC) uptake constant (K), mean transit time (MTT), and parenchymal transit time (PTT) in the diagnosis of obstructive uro/nephropathy. The study included 226 people: 20 healthy volunteers, for whom normative values of assessed parameters were determined, and 206 patients. Reproducibility of results obtained by two independent operators, specificity, correlation with estimated GFR (eGFR), and Cohen’s kappa were used to evaluate reliability of assessed parameters. Normative values were as follows: K ≥ 1.6, MTT ≤ 250 s, and PTT ≤ 225 s. Reproducibility of determination of K (rs = 0.99) and MTT (rs = 0.98) was significantly higher than that of PTT (rs = 0.95) (p = 0.001). Specificity was 100% for K, 81% for MTT, and 91% for PTT. Correlation of eGFR with K (rs = 0.89) was significantly higher than with PTT (rs = 0.53) and with split function (SF) (rs = 0.66) (p < 0.0001). Cohen’s kappa was κ = 0.89 for K, κ = 0.88 for MTT, and κ = 0.77 for PTT. In a group of patients where standard DRS parameters are unreliable (bilateral obstructive uro/nephropathy or single functioning kidney), the use of K (the most effective among assessed parameters) changed the classification of 23/79 kidneys (29%). K enables reproducible assessment of absolute, individual kidney function without modifying routine DRS protocol. Diagnostic value of MTT and PTT is limited.

1 January 2019
Verified
Journal Article
Closed access
JKJacek Kusmierek
Jacek Kusmierek
APAnna Płachcińska
Anna Płachcińska
Józef Rotblat, a nuclear physicist born and educated in Poland, is the only laureate of the Nobel Peace Prize, who made a significant contribution to the development of nuclear medicine. In 1948 he went down in the annals of nuclear medicine by obtaining, with extarnal measurements, the first "image " of a function of an internal organ - thyroid gland, by registering gamma rays with a collimated Geiger counter at many points of the patient's neck and chest. He was awarded the Nobel Prize in Rotblat in 1995 for organizing, together with the a British philosopher Bertrand Russell, the international, peaceful movement of scholars for the eradication of weapons of mass destruction (Pugwash) and multi-annual activity in this movement.