Gabriele Pesarini

Dr. Gabriele Pesarini

Division of Cardiology, Department of Medicine, University of Verona Medical School, Verona, Italy
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 August 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
ABAndrea Bottardi
Andrea Bottardi
GPGuy F A Prado
Guy F A Prado
MLMattia Lunardi
Mattia Lunardi
SFSIMONE FEZZI
SIMONE FEZZI
Gabriele PesariniGabriele Pesarini
Gabriele Pesarini
FRFlavio Ribichini
Flavio Ribichini
Despite significant goals achieved in diagnosis and treatment in recent decades, coronary artery disease (CAD) remains a high mortality entity and continues to pose substantial challenges to healthcare systems globally. After the latest guidelines, novel data have emerged and have not been yet considered for routine practice. The scope of this review is to go beyond the guidelines, providing insights into the most recent clinical updates in CAD, focusing on non-invasive diagnostic techniques, risk stratification, medical management and interventional therapies in the acute and stable scenarios. Highlighting and synthesizing the latest developments in these areas, this review aims to contribute to the understanding and management of CAD helping healthcare providers worldwide.

1 October 2023 in Circulation: Cardiovascular Interventions
Verified
Journal Article
Closed access
SFSimone Fezzi
Simone Fezzi
DDDaixin Ding
Daixin Ding
RSRoberto Scarsini
Roberto Scarsini
JHJiayue Huang
Jiayue Huang
PSPaolo Alberto Del Sole
Paolo Alberto Del Sole
Shengxian TuShengxian Tu
Shengxian Tu
BACKGROUND: Angiography-derived computational physiology is an appealing alternative to pressure-wire coronary physiology assessment. However, little is known about its reliability in the setting of severe aortic stenosis. This study sought to provide an integrated assessment of epicardial and microvascular coronary circulation by means of single-view angiography-derived physiology in patients with severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI). METHODS: Pre-TAVI angiographic projections of 198 stenotic coronary arteries (123 patients) were analyzed by means of Murray’s law-based quantitative flow ratio and angiography microvascular resistance. Wire-based reference measurements were available for comparison: fractional flow reserve (FFR) in all cases, instantaneous wave-free ratio in 148, and index of microvascular resistance in 42 arteries. RESULTS: No difference in terms of the number of ischemia-causing stenoses was detected between FFR ≤0.80 and Murray’s law-based quantitative flow ratio ≤0.80 (19.7% versus 19.2%; P =0.899), while this was significantly higher when instantaneous wave-free ratio ≤0.89 (44.6%; P =0.001) was used. The accuracy of Murray’s law-based quantitative flow ratio ≤0.80 in predicting pre-TAVI FFR ≤0.80 was significantly higher than the accuracy of instantaneous wave-free ratio ≤0.89 (93.4% versus 77.0%; P =0.001), driven by a higher positive predictive value (86.9% versus 50%). Similar findings were observed when considering post-TAVI FFR ≤0.80 as reference. In 82 cases with post-TAVI angiographic projections, Murray’s law-based quantitative flow ratio values remained stable, with a low rate of reclassification of stenosis significance (9.9%), similar to FFR and instantaneous wave-free ratio. Angiography microvascular resistance demonstrated a significant correlation (Rho=0.458; P =0.002) with index of microvascular resistance, showing an area under the curve of 0.887 (95% CI, 0.752–0.964) in predicting index of microvascular resistance ≥25. CONCLUSIONS: Angiography-derived physiology provides a valid, reliable, and systematic assessment of the coronary circulation in a complex scenario, such as severe aortic stenosis.

1 March 2024 in Circulation: Cardiovascular Interventions
Verified
Journal Article
Closed access
RSRoberto Scarsini
Roberto Scarsini
RKRafail A. Kotronias
Rafail A. Kotronias
FMFrancesco Della Mora
Francesco Della Mora
LPLeonardo Portolan
Leonardo Portolan
SAStefano Andreaggi
Stefano Andreaggi
MTMaria Giovanna Trivieri
Maria Giovanna Trivieri
BACKGROUND: Patients with ST-segment–elevation myocardial infarction but no coronary microvascular injury are at low risk of early cardiovascular complications (ECC). We aim to assess whether nonhyperemic angiography-derived index of microcirculatory resistance (NH-IMR angio ) could be a user-friendly tool to identify patients at low risk of ECC, potentially candidates for expedited care pathway and early hospital discharge. METHODS: Retrospective analysis of 2 independent, international, prospective, observational cohorts included 568 patients with ST-segment–elevation myocardial infarction. NH-IMR angio was calculated based on standard coronary angiographic views with 3-dimensional-modeling and computational analysis of the coronary flow. RESULTS: Overall, ECC (a composite of cardiovascular death, cardiogenic shock, acute heart failure, life-threatening arrhythmias, resuscitated cardiac arrest, left ventricular thrombus, post-ST-segment–elevation myocardial infarction mechanical complications, and rehospitalization for acute heart failure or acute myocardial infarction at 30 days follow-up), occurred in 54 (9.3%) patients. NH-IMR angio was significantly correlated with pressure/thermodilution-based index of microcirculatory resistance (r=0.607; P <0.0001) and demonstrated good accuracy in predicting ECC (area under the curve, 0.766 [95% CI, 0.706–0.827]; P <0.0001). Importantly, ECC occurred more frequently in patients with NH-IMR angio ≥40 units (18.1% versus 1.4%; P <0.0001). At multivariable analysis, NH-IMR angio provided incremental prognostic value to conventional clinical, angiographic, and echocardiographic features (adjusted-odds ratio, 14.861 [95% CI, 5.177–42.661]; P <0.0001). NH-IMR angio <40 units showed an excellent negative predictive value (98.6%) in ruling out ECC. Discharging patients with NH-IMR angio <40 units at 48 hours after admission would reduce the total in-hospital stay by 943 days (median 2 [1–4] days per patient). CONCLUSIONS: NH-IMR angio is a valuable risk-stratification tool in patients with ST-segment–elevation myocardial infarction. NH-IMR angio guided strategies to early discharge may contribute to safely shorten hospital stay, optimizing resources utilization.

27 April 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Gabriele PesariniGabriele Pesarini
Gabriele Pesarini
GVGabriele Venturi
Gabriele Venturi
DTDomenico Tavella
Domenico Tavella
LGLeonardo Gottin
Leonardo Gottin
MLMattia Lunardi
Mattia Lunardi
FRFlavio Ribichini
Flavio Ribichini
Background: The aim of this research is to describe the performance over time of transcatheter aortic valve implantations (TAVIs) in a high-volume center with a contemporary, real-world population. Methods: Patients referred for TAVIs at the University Hospital of Verona were prospectively enrolled. By cumulative sum failures analysis (CUSUM), procedural-control curves for standardized combined endpoints—as defined by the Valve Academic Research Consortium-2 (VARC-2)—were calculated and analyzed over time. Acceptable and unacceptable limits were derived from recent studies on TAVI in intermediate and low-risk patients to fit the higher required standards for current indications. Results: A total of 910 patients were included. Baseline risk scores significantly reduced over time. Complete procedural control was obtained after approximately 125 and 190 cases for device success and early safety standardized combined endpoints, respectively. High risk patients (STS ≥ 8) had poorer outcomes, especially in terms of VARC-2 clinical efficacy, and required a higher case load to maintain in-control and proficient procedures. Clinically relevant single endpoints were all influenced by operator’s experience as well. Conclusions: Quality-control analysis for contemporary TAVI interventions based on standardized endpoints suggests the need for relevant operator’s experience to achieve and maintain optimal clinical results, especially in higher-risk subjects.

1 June 2025 in Circulation: Cardiovascular Interventions
Verified
Journal Article
Closed access
EGEmanuele Gallinoro
Emanuele Gallinoro
RSRoberto Scarsini
Roberto Scarsini
MAMarco B. Ancona
Marco B. Ancona
Pasquale PaolissoPasquale Paolisso
Pasquale Paolisso
LPLeonardo Portolan
Leonardo Portolan
EBEmanuele Barbato
Emanuele Barbato
BACKGROUND: The anatomic and physiological changes associated with severe aortic stenosis may influence the functional evaluation of coronary stenoses. In this study, we aimed to assess changes in functional resting and hyperemic indices before and immediately after transcatheter aortic valve implantation (TAVI) and their relationship with microvascular resistance. METHODS: In this pooled analysis of 3 prospective observational studies, fractional flow reserve (FFR), resting full-cycle ratio (RFR), and resting distal coronary pressure to aortic pressure ratio (Pd/Pa) were measured in patients with severe aortic stenosis before and after TAVI in the left anterior descending artery. Coronary microcirculation was also assessed using thermodilution-based methods, with microvascular resistance reserve (cutoff ≤3) used to identify coronary microvascular dysfunction. RESULTS: A total of 126 patients were included. Baseline Pd/Pa, RFR, and FFR measurements were 0.93±0.04, 0.90±0.07, and 0.89±0.07, respectively. Immediately post-TAVI, a small but significant decrease was observed for both RFR and FFR (RFR, 0.88±0.08; FFR, 0.88±0.08; P <0.05 for all). Coronary flow reserve and microvascular resistance reserve also remained unchanged. Applying the established cutoff values, 16 (12.7%) vessels had a positive FFR, while a higher proportion of vessels were positive for Pd/Pa and RFR (35.7% and 43.7%, respectively; P <0.001). The concordance between pre- and post-TAVI FFR was higher (92.8%) compared with Pd/Pa (75.4%) and RFR (73.8%) ( P <0.001 for both). The rate of disagreement between resting and hyperemic indices remained unchanged, regardless of the presence of coronary microvascular dysfunction. CONCLUSIONS: TAVI is associated with a small but significant reduction in FFR and RFR immediately post-procedure. Overall, the agreement between pre- and post-TAVI values of FFR was higher compared with resting indices.

31 December 2020 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MLMattia Lunardi
Mattia Lunardi
MPMichele Pighi
Michele Pighi
GVGabriele Venturi
Gabriele Venturi
PSPaolo Alberto Del Sole
Paolo Alberto Del Sole
Gabriele PesariniGabriele Pesarini
Gabriele Pesarini
FRFlavio Ribichini
Flavio Ribichini
Background. Coronary artery disease (CAD) is a common finding among patients undergoing trans-catheter aortic valve implantation (TAVI), who often present severely calcified coronary lesions. Evidence is scarce about the use of rotational atherectomy (RA) in this setting, in particular regarding long-term outcome. Methods. RA was performed on severely calcified coronary lesions concomitant with TAVI in a consecutive series of patients treated between 2010 and 2020. Immediate and long-term clinical outcomes are reported. Results. A concomitant CAD (coronary stenosis visually > 50%) was observed in 402/845 (47.6%) consecutive patients undergoing TAVI at the University Hospital of Verona. Angioplasty was performed in 104 patients (12.3%). Among these, 19 patients (18.3%, 20 coronary arteries), were treated with RA after TAVI: 10 after implantation of a balloon-expandable trans-catheter valve and 9 after a self-expandable valve. All procedures were successful. Hypotension occurred in 3 patients (15.8%), with rapid recovery after the procedure; CI-AKI (contrast-induced acute kidney injury) in 3 patients (15.8%), of which two recovered within discharge. At a median follow-up of 21.5 months (Q1–3: 6–36) event free survival was 83.3%. Only one patient suffered a target vessel failure >2 years after RA. Neither stroke nor peri-procedural infarctions were detected. Conclusions. RA concomitant with TAVI was feasible and safe in patients treated with implantation of either self-expandable, or balloon-expandable trans-catheter aortic valves. Long-term clinical events related to the coronary procedure were extremely infrequent and the survival rate at median follow-up of 21.5 months was 83.3%.