Purpose: The purpose of this paper is to provide a detailed appraisal of the quality of domestic retrofits. Design/methodology/approach: This paper presents the results of technical surveys on 51 retrofits undertaken before, during and after the retrofits. Findings: Failures are observed to be endemic and characterised into five themes: 72 per cent showed moisture issues pre-retrofit, 68 per cent had moisture risks post-retrofit, 62 per cent did not adopt a whole house approach, 16 per cent showed inadequate quality assurance protocols and 64 per cent showed evidence of insufficient design detailing. Each theme is further subcategorised with a view to identifying implications for future policy. Research limitations/implications: The findings suggest the 10 per cent Ofgem retrofit failure rates predictions are an underestimate and so there may be a need for additional investigations to understand the trend across the UK. Practical implications: Recommendations to reduce the failure rates may include making changes to the current inspection regime, widening understanding among installers; providing standard repeatable designs for repeated features; and empowering occupants to trigger inspections. Social implications: The sample is representative of a substantial proportion of the homes in the UK suggesting that retrofit quality may in many instances be below the required standards. Originality/value: Risks of moisture issues and underperformance in domestic retrofit are a concern for government industry and households. This research shows that many installation failures are the result of not implementing existing guidelines and a change to the enforcement of standards may be needed to enact a fundamental change in installer practice and process control.

3 July 2017 in Construction Research and Innovation
Verified
Journal Article
Open access
CGChristopher Andrew Gorse
Christopher Andrew Gorse
JSJohn Sturges
John Sturges
While many factors will have contributed to the catastrophe at Grenfell Tower, it is clear that the structure itself behaved in a way that no one could possibly have intended. In this article the authors sample the bewildering and sometimes apparently contradictory directions provided by building regulations, and review how fire safety precautions, while seeming adequate on paper, can be undermined on contact with observed on-site practice.

24 April 2019
Verified
Book Chapter
Closed access
PDF file
CGChristopher Andrew Gorse
Christopher Andrew Gorse
JPJames Parker
James Parker
FTFelix Thomas
Felix Thomas
MFMartin Fletcher
Martin Fletcher
GFGraham Ferrier
Graham Ferrier
NRNeill Ryan
Neill Ryan

14 November 2015
Verified
Book Chapter
Closed access
PDF file
CGChristopher Andrew Gorse
Christopher Andrew Gorse
MBMatthew Brooke-Peat
Matthew Brooke-Peat
JPJames Parker
James Parker
FTFelix Thomas
Felix Thomas

14 November 2015
Verified
Book Chapter
Closed access
PDF file
CGChristopher Andrew Gorse
Christopher Andrew Gorse
MSMelanie Smith
Melanie Smith
DGDavid Glew
David Glew
FTFelix Thomas
Felix Thomas
DSDominic Miles Shenton
Dominic Miles Shenton
DFDavid Farmer
David Farmer

14 November 2021
Verified
Book Chapter
Closed access
PDF file
JSJohn Sturges
John Sturges
CGChristopher Andrew Gorse
Christopher Andrew Gorse