David Glew

Prof. Dr. David Glew

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 April 2010 in Oryx
Verified
Journal Article
Open access
PDF file
IBIan Bateman
Ian Bateman
BFBrendan Fisher
Brendan Fisher
EFEmily Fitzherbert
Emily Fitzherbert
DGDavid Glew
David Glew
RNRobin Naidoo
Robin Naidoo
Increasing demand for cooking oil and biofuels has made palm oil, > 80% of which is grown in South-east Asia, the dominant globally traded vegetable oil. However, this region is host to some of the world’s most biodiverse and threatened tropical forests. Strategic engagement with commercial operations is increasingly recognized to be an essential part of the solution for raising funds for conservation initiatives, raising consumer consciousness and potentially stemming environmental degradation. Linking market incentives towards conservation is also of critical importance because it is becoming widely recognized that conservation needs to begin to address the wider countryside (outside protected areas) where human–wildlife interactions are frequent and impacts are large. Using the Sumatran tiger Panthera tigris sumatrae as both a threatened species in its own right and emblematic for wider species diversity, we show that western consumers are willing to pay a significant premium for products using palm oil grown in a manner that reduces impacts on such species. Results suggest that the price premium associated with a ‘tiger-friendly’ accreditation may provide a useful additional tool to raise conservation funds and, within the right institutional context, serve as an inducement to address the problem of habitat and species loss.

13 November 2017 in International Journal of Building Pathology and Adaptation
Verified
Journal Article
Closed access
DGDavid Glew
David Glew
MSMelanie B. Smith
Melanie B. Smith
DMDominic Miles-Shenton
Dominic Miles-Shenton
CGChristopher Andrew Gorse
Christopher Andrew Gorse
Purpose: The purpose of this paper is to provide a detailed appraisal of the quality of domestic retrofits. Design/methodology/approach: This paper presents the results of technical surveys on 51 retrofits undertaken before, during and after the retrofits. Findings: Failures are observed to be endemic and characterised into five themes: 72 per cent showed moisture issues pre-retrofit, 68 per cent had moisture risks post-retrofit, 62 per cent did not adopt a whole house approach, 16 per cent showed inadequate quality assurance protocols and 64 per cent showed evidence of insufficient design detailing. Each theme is further subcategorised with a view to identifying implications for future policy. Research limitations/implications: The findings suggest the 10 per cent Ofgem retrofit failure rates predictions are an underestimate and so there may be a need for additional investigations to understand the trend across the UK. Practical implications: Recommendations to reduce the failure rates may include making changes to the current inspection regime, widening understanding among installers; providing standard repeatable designs for repeated features; and empowering occupants to trigger inspections. Social implications: The sample is representative of a substantial proportion of the homes in the UK suggesting that retrofit quality may in many instances be below the required standards. Originality/value: Risks of moisture issues and underperformance in domestic retrofit are a concern for government industry and households. This research shows that many installation failures are the result of not implementing existing guidelines and a change to the enforcement of standards may be needed to enact a fundamental change in installer practice and process control.

1 April 2018 in Energy and Buildings
Verified
Journal Article
Closed access
AHA. Hardy
A. Hardy
DGDavid Glew
David Glew
CGChristopher Gorse
Christopher Gorse
MFM. Fletcher
M. Fletcher

20 March 2024 in Buildings
Verified
Journal Article
Open access
PDF file
CTChristopher Tsang
Christopher Tsang
JPJim Parker
Jim Parker
DGDavid Glew
David Glew
A substantial number of dwellings in the UK have poor building fabric, leading to higher carbon emissions, fuel expenses, and the risk of cold homes. To tackle these challenges, domestic energy efficiency policies are being implemented. One effective approach is the use of energy models, which enable sensitivity analysis to provide valuable insights for policymakers. This study employed dynamic thermal simulation models for 32 housing archetypes representative of solid-walled homes in the UK to calculate the heat loss and the sensitivity coefficient per building fabric feature, after which a metric Heat Loss Sensitivity (HLS) index was established to guide the selection of retrofit features for each archetype. The building fabric features’ inputs were then adjusted to establish both lower and upper bounds, simulating low and high performance levels, to predict the how space heating energy demand varies. The analysis was extended by replicating the process with various scenarios considering climates, window-to-wall ratios, and overshadowing. The findings highlight the external wall as the primary consideration in retrofitting due to its high HLS index, even at high window-to-wall ratios. It was also established that dwelling type is important in retrofit decision-making, with floor and loft retrofits having a high HLS index in bungalows. Furthermore, the analysis underlines the necessity for Standard Assessment Procedure assessors to evaluate loft U-value and air permeability rates prior to implementing retrofit measures, given the significance of these factors in the lower and upper bounds analysis. Researchers globally can replicate the HLS index approach, facilitating the implementation of housing retrofit policies worldwide.


28 May 2025 in Buildings and Cities
Verified
Journal Article
Open access
PDF file
DGDavid Glew
David Glew
FTFelix Thomas
Felix Thomas
DMDominic Miles-Shenton
Dominic Miles-Shenton
JPJim Parker
Jim Parker
Fan pressurisation tests (FPTs) are commonly used to measure air leakage in homes, to provide evidence for compliance with energy and ventilation standards in building regulations and inform energy models. The results are presented of 37 pressurisation and co-pressurisation tests on attached homes in the UK which measured inter-dwelling air exchanges during the FPTs. On average, 21% of the air leakage measured by the FPTs was found to be inter-dwelling rather than inside-to-outside air exchange, i.e. homes are more airtight than FPTs indicate, which is important when assessing energy efficiency and ventilation performance thresholds. Not accounting for inter-dwelling air exchanges poses a risk of under-ventilation and misclassification of homes deemed suitable for natural ventilation. Using the FPT result to replace default values for airtightness in energy models used to create Energy Performance Certificates (EPCs) for 11 of the case study homes improved their energy efficiency rating (EER), indicating default airtightness values used in EPCs used were overestimating the air leakage. Using the co-pressurisation value resulted in an additional EER point. These modest improvements represented a 5%, 8% and 3% reduction in predicted annual carbon emission, space heating demand and fuel bills, respectively. Practice relevance The airtightness of homes is fundamental to their energy efficiency and ventilation requirements. The FPT is commonly used to measure airtightness in homes; however, this research has shown that the FPT can overpredict air leakage in attached homes due to the elevated pressures during the test cause inter-dwelling air exchanges not experienced under non-test conditions. This may affect the accuracy of FPTs in attached homes and the appropriateness of using the FPT result to inform building regulation compliance, ventilation decisions and energy models. The research has implications for FPT standards, testing practitioners and professional bodies, energy modellers, ventilation designers, policymakers, and regulations. The development of further knowledge, industry guidance and protocols is required for inter-dwelling air exchange taking place during the FPT, particularly for different house type, form and construction.