Ahmed Bahrani

Dr. Ahmed Bahrani

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2017 in Journal of Stroke and Cerebrovascular Diseases
Verified
Journal Article
Open access
ABAhmed Bahrani
Ahmed Bahrani
DPDavid K. Powell
David K. Powell
GYGuoqiang Yu
Guoqiang Yu
EJEleanor S. Johnson
Eleanor S. Johnson
GJGregory A. Jicha
Gregory A. Jicha
CSCharles D. Smith
Charles D. Smith
This study aims to add clarity to the relationship between deep and periventricular brain white matter hyperintensities (WMHs), cerebral blood flow (CBF), and cerebrovascular risk in older persons. Deep white matter hyperintensity (dWMH) and periventricular white matter hyperintensity (pWMH) and regional gray matter (GM) and white matter (WM) blood flow from arterial spin labeling were quantified from magnetic resonance imaging scans of 26 cognitively normal elderly subjects stratified by cerebrovascular disease (CVD) risk. Fluid-attenuated inversion recovery images were acquired using a high-resolution 3-dimensional (3-D) sequence that reduced partial volume effects seen with slice-based techniques. dWMHs but not pWMHs were increased in patients at high risk of CVD; pWMHs but not dWMHs were associated with decreased regional cortical (GM) blood flow. We also found that blood flow in WM is decreased in regions of both pWMH and dWMH, with a greater degree of decrease in pWMH areas. WMHs are usefully divided into dWMH and pWMH regions because they demonstrate differential effects. 3-D regional WMH volume is a potentially valuable marker for CVD based on associations with cortical CBF and WM CBF.

19 July 2019 in Brain Sciences
Verified
Journal Article
Open access
PDF file
OAOmar M. Al-Janabi
Omar M. Al-Janabi
CBChristopher E. Bauer
Christopher E. Bauer
LGLarry B. Goldstein
Larry B. Goldstein
RMRichard R. Murphy
Richard R. Murphy
ABAhmed Bahrani
Ahmed Bahrani
GJGregory Jicha
Gregory Jicha
Subcortical white matter hyperintensities (WMHs) in the aging population frequently represent vascular injury that may lead to cognitive impairment. WMH progression is well described, but the factors underlying WMH regression remain poorly understood. A sample of 351 participants from the Alzheimer’s Disease Neuroimaging Initiative 2 (ADNI2) was explored who had WMH volumetric quantification, structural brain measures, and cognitive measures (memory and executive function) at baseline and after approximately 2 years. Selected participants were categorized into three groups based on WMH change over time, including those that demonstrated regression (n = 96; 25.5%), stability (n = 72; 19.1%), and progression (n = 209; 55.4%). There were no significant differences in age, education, sex, or cognitive status between groups. Analysis of variance demonstrated significant differences in atrophy between the progression and both regression (p = 0.004) and stable groups (p = 0.012). Memory assessments improved over time in the regression and stable groups but declined in the progression group (p = 0.003; p = 0.018). WMH regression is associated with decreased brain atrophy and improvement in memory performance over two years compared to those with WMH progression, in whom memory and brain atrophy worsened. These data suggest that WMHs are dynamic and associated with changes in atrophy and cognition.

24 September 2018 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
PDF file
SMSiavash Mazdeyasna
Siavash Mazdeyasna
Chong HuangChong Huang
Chong Huang
MZMingjun Zhao
Mingjun Zhao
NANneamaka B. Agochukwu
Nneamaka B. Agochukwu
ABAhmed Bahrani
Ahmed Bahrani
Guoqiang YuGuoqiang Yu
Guoqiang Yu
A noncontact electron multiplying charge-coupled-device (EMCCD)-based speckle contrast diffuse correlation tomography (scDCT) technology has been recently developed in our laboratory, allowing for noninvasive three-dimensional measurement of tissue blood flow distributions. One major remaining constraint in the scDCT is the assumption of a semi-infinite tissue volume with a flat surface, which affects the image reconstruction accuracy for tissues with irregular geometries. An advanced photometric stereo technique (PST) was integrated into the scDCT system to obtain the surface geometry in real time for image reconstruction. Computer simulations demonstrated that a priori knowledge of tissue surface geometry is crucial for precisely reconstructing the anomaly with blood flow contrast. Importantly, the innovative integration design with one single-EMCCD camera for both PST and scDCT data collection obviates the need for offline alignment of sources and detectors on the tissue boundary. The in vivo imaging capability of the updated scDCT is demonstrated by imaging dynamic changes in forearm blood flow distribution during a cuff-occlusion procedure. The feasibility and safety in clinical use are evidenced by intraoperative imaging of mastectomy skin flaps and comparison with fluorescence angiography.

9 July 2018 in IEEE Journal of Selected Topics in Quantum Electronics
Verified
Journal Article
Closed access
Chong HuangChong Huang
Chong Huang
YGYutong Gu
Yutong Gu
JCJing Chen
Jing Chen
ABAhmed Bahrani
Ahmed Bahrani
EJElie G. Abu Jawdeh
Elie G. Abu Jawdeh
LCLei Chen
Lei Chen
Continuous and longitudinal monitoring of cerebral blood flow (CBF) in animal models provides information for studying the mechanisms and interventions of various cerebral diseases. Since anesthesia may affect brain hemodynamics, researchers have been seeking wearable devices for use in conscious animals. We present a wearable diffuse speckle contrast flowmeter (DSCF) probe for monitoring CBF variations in mice. The DSCF probe consists of a small low-power near-infrared laser diode as a point source and an ultrasmall low-power CMOS camera as a two-dimensional detector array, which can be affixed on a mouse head. The movement of red blood cells in brain cortex (i.e., CBF) produces spatial fluctuations of laser speckles, which are captured by the camera. The DSCF system was calibrated using tissue phantoms and validated in a human forearm and mouse brains for continuous monitoring of blood flow increases and decreases against the established technologies. Significant correlations were observed among these measurements (R 2 ≥ 0.80, p <; 10 -5 ). This small fiberless probe has the potential to be worn by a freely moving conscious mouse. Moreover, the flexible source-detector configuration allows for varied probing depths up to ~8 mm, which is sufficient for transcranially detecting CBF in the cortices of rodents and newborn infants.

1 July 2017 in Plastic and Reconstructive Surgery
Verified
Journal Article
Closed access
NANneamaka B. Agochukwu
Nneamaka B. Agochukwu
CHChong Huang
Chong Huang
MZMingjun Zhao
Mingjun Zhao
ABAhmed Bahrani
Ahmed Bahrani
LCLi Chen
Li Chen
LWLesley Wong
Lesley Wong
Summary: A new advanced technology, noncontact diffuse correlation spectroscopy, has been recently developed for the measurement of tissue blood flow through analyzing the motions of red blood cells in deep tissues. This technology is portable, inexpensive, and noninvasive, and can measure up to 1.5-cm tissue depth. In this prospective study, the authors aimed to explore the use of this novel device in the prediction of mastectomy skin flap necrosis. The noncontact diffuse correlation spectroscopy device was used to measure mastectomy skin flap flow in patients undergoing mastectomy and immediate implant-based breast reconstruction before and immediately after mastectomy, and after placement of the prosthesis. Patients were tracked for the development of complications, including skin necrosis and the need for further surgery. Nineteen patients were enrolled in the study. Four patients (21 percent) developed skin necrosis, one of which required additional surgery. The difference in relative blood flow levels immediately after mastectomy in patients with or without necrosis was statistically significant, with values of 0.27 ± 0.11 and 0.66 ± 0.22, respectively (p = 0.0005). Relative blood flow measurements immediately after mastectomy show a significant high accuracy in prediction of skin flap necrosis, with an area under the receiver operating characteristic curve of 0.95 (95 percent confidence interval, 0.81 to 1). The noncontact diffuse correlation spectroscopy device is a promising tool that provides objective information regarding mastectomy skin flap viability intraoperatively, allowing surgeons early identification of those compromised and ischemic flaps with the hope of potentially salvaging them. CLINICAL QUESTION/LEVEL OF EVIDENCE: Diagnostic, IV.

26 July 2020 in Journal of Biophotonics
Verified
Journal Article
Closed access
PDF file
ABAhmed Bahrani
Ahmed Bahrani
WKWeikai Kong
Weikai Kong
YSYu Shang
Yu Shang
CHChong Huang
Chong Huang
CSCharles D. Smith
Charles D. Smith
GYGuoqiang Yu
Guoqiang Yu