Guoqiang Yu

Dr. Guoqiang Yu


Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2005 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
PDF file
Guoqiang YuGuoqiang Yu
Guoqiang Yu
Turgut DurduranTurgut Durduran
Turgut Durduran
GLGwen Lech
Gwen Lech
CZChao Zhou
Chao Zhou
BCBritton Chance
Britton Chance
AYArjun Yodh
Arjun Yodh
We have employed near-infrared optical methods to measure noninvasively the dynamics of muscle blood flow and oxygen saturation (StO2) during cuff occlusion and plantar flexion exercise. Relative muscle oxygen consumption (rVO2) was also computed from these data. Diffuse correlation spectroscopy provides information about blood flow, and diffuse reflectance spectroscopy provides information about blood oxygenation. Ten healthy subjects and one patient with peripheral arterial disease (PAD) were studied during 3-min arterial cuff occlusion of arm and leg, and during 1-min plantar flexion exercise. Signals from different layers (cutaneous tissues and muscles) during cuff occlusion were differentiated, revealing strong hemodynamic responses from muscle layers. During exercise in healthy legs, the observed ∼4.7 fold increase in relative blood flow (rBF) was significantly lower than the corresponding increase in rVO2(∼7 fold). The magnitudes of rBF and rVO2 during exercise in the PAD patient were ∼1/2 of the healthy controls, and the StO2 recovery time was twice that of the controls. The hybrid instrument improves upon current technologies for measuring muscle responses by simultaneously measuring rBF and StO2. The instrument thus provides a method for evaluation of microcirculation and muscle metabolism in patients with vascular diseases. © 2005 Society of Photo-Optical Instrumentation Engineers.

1 January 2010 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
Turgut DurduranTurgut Durduran
Turgut Durduran
CZChao Zhou
Chao Zhou
EBErin Buckley
Erin Buckley
MKMeeri N. Kim
Meeri N. Kim
Guoqiang YuGuoqiang Yu
Guoqiang Yu
DLDaniel J. Licht
Daniel J. Licht
Approximately 30,000 infants are born each year in the United States with congenital heart disease (CHD), with about a third requiring major surgical repair in the first few months of life.1 Recent advances in cardiac surgery for complex CHD have minimized infant mortality. Thus, the current focus in the clinical community is oriented toward preventing neurologic injury and improving neurocognitive outcome in these high-risk babies who grow up to face various medical and academic challenges.2, 3

1 January 2007 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
PDF file
CZChao Zhou
Chao Zhou
RCRegine Choe
Regine Choe
NSNatasha Shah
Natasha Shah
Turgut DurduranTurgut Durduran
Turgut Durduran
Guoqiang YuGuoqiang Yu
Guoqiang Yu
AYArjun Yodh
Arjun Yodh
We combine diffuse optical spectroscopy (DOS) and diffuse correlation spectroscopy (DCS) to noninvasively monitor early hemodynamic response to neoadjuvant chemotherapy in a breast cancer patient. The potential for early treatment monitoring is demonstrated. Within the first week of treatment (day 7) DOS revealed significant changes in tumor/normal contrast compared to pretreatment (day 0) tissue concentrations of deoxyhemoglobin (rctHHbT∕N=69±21%), oxyhemoglobin (rctO2HbT∕N=73±25%), total hemoglobin (rctTHbT∕N=72±17%), and lipid concentration (rctLipidT∕N=116±13%). Similarly, DCS found significant changes in tumor/normal blood flow contrast (rBFT∕N=75±7% on day 7 with respect to day 0). Our observations suggest the combination of DCS and DOS enhances treatment monitoring compared to either technique alone. The hybrid approach also enables construction of indices reflecting tissue metabolic rate of oxygen, which may provide new insights about therapy mechanisms.

1 January 2009 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
CZChao Zhou
Chao Zhou
SEStephanie A. Eucker
Stephanie A. Eucker
Turgut DurduranTurgut Durduran
Turgut Durduran
Guoqiang YuGuoqiang Yu
Guoqiang Yu
JRJill Ralston
Jill Ralston
AYArjun Yodh
Arjun Yodh
Traumatic brain injury (TBI) is a leading cause of childhood morbidity and mortality in the United States, with an annual rate of ∼200 per 100,000 children requiring hospitalization.1 The increasing monetary costs result not only from the acute intensive care for these patients but also from long-term care that is often necessary. Brain injuries in these patients result from both the primary trauma and secondary insults, such as reductions in cerebral blood flow, derangements in cerebral metabolism, and the ensuing ischemic injuries that continue to progress well after the traumatic event. Optimal therapeutic efficacy thus requires knowledge of cerebral blood flow, oxygen supply, and oxygen consumption in patients after TBI. In this study, we explored the feasibility of two diffuse optical techniques, diffuse reflectance spectroscopy (DRS) and diffuse correlation spectroscopy (DCS), for continuous, noninvasive measurement of cerebral blood flow and blood oxygenation at the bedside.

17 June 2011 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
DIDaniel Irwin
Daniel Irwin
LDLixin Dong
Lixin Dong
YSYu Shang
Yu Shang
RCRan Cheng
Ran Cheng
MKMahesh Kudrimoti
Mahesh Kudrimoti
Guoqiang YuGuoqiang Yu
Guoqiang Yu
In this study we evaluate the influences of optical property assumptions on near-infrared diffuse correlation spectroscopy (DCS) flow index measurements. The optical properties, absorption coefficient (µa) and reduced scattering coefficient (µs′), are independently varied using liquid phantoms and measured concurrently with the flow index using a hybrid optical system combining a dual-wavelength DCS flow device with a commercial frequency-domain tissue-oximeter. DCS flow indices are calculated at two wavelengths (785 and 830 nm) using measured µa and µs′ or assumed constant µa and µs′. Inaccurate µs′ assumptions resulted in much greater flow index errors than inaccurate µa. Underestimated/overestimated µs′ from −35%/+175% lead to flow index errors of +110%/−80%, whereas underestimated/overestimated µa from −40%/+150% lead to −20%/+40%, regardless of the wavelengths used. Examination of a clinical study involving human head and neck tumors indicates up to +280% flow index errors resulted from inter-patient optical property variations. These findings suggest that studies involving significant µa and µs′ changes should concurrently measure flow index and optical properties for accurate extraction of blood flow information.

1 January 2006 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
PDF file
Ulas SunarUlas Sunar
Ulas Sunar
HQHarry Quon
Harry Quon
Turgut DurduranTurgut Durduran
Turgut Durduran
JZJun Zhang
Jun Zhang
JDJuan Du
Juan Du
AYArjun Yodh
Arjun Yodh
This pilot study explores the potential of noninvasive diffuse correlation spectroscopy (DCS) and diffuse reflectance spectroscopy (DRS) for monitoring early relative blood flow (rBF), tissue oxygen saturation (StO2), and total hemoglobin concentration (THC) responses to chemo-radiation therapy in patients with head and neck tumors. rBF, StO2, and THC in superficial neck tumor nodes of eight patients are measured before and during the chemo-radiation therapy period. The weekly rBF, StO2, and THC kinetics exhibit different patterns for different individuals, including significant early blood flow changes during the first two weeks. Averaged blood flow increases (52.7±9.7)% in the first week and decreases (42.4±7.0)% in the second week. Averaged StO2 increases from (62.9±3.4)% baseline value to (70.4±3.2)% at the end of the second week, and averaged THC exhibits a continuous decrease from pretreatment value of (80.7±7.0)[μM] to (73.3±8.3)[μM] at the end of the second week and to (63.0±8.1)[μM] at the end of the fourth week of therapy. These preliminary results suggest daily diffuse-optics-based therapy monitoring is feasible during the first two weeks and may have clinical promise.