The rise of distributed power generation systems comes along with an energy storage systems increment. Moreover, the expensiveness of batteries and dc capacitors generate interest on extending their lifetime, directly related with dc current ripple. Unlike other multifrequency approaches, in this paper, the harmonic reference currents are calculated to reduce the low-frequency active power fluctuations, obtaining superior results in contrast with existing techniques and effectively alleviating associated harmful effects. As the harmonic currents are not set to zero in this system, an approach that minimizes current total harmonic distortion while eliminates the main harmonic fluctuations is developed, leading to an optimized performance in terms of power quality and power filtering. Finally, simulation and experimental results in unbalanced and distorted grid conditions prove the advantages of the proposed technique.
10 September 2018 in IEEE Transactions on Industrial Electronics
The importance of distributed generation and renewable energies inclusion has lead to obtain the maximum from power converters, in terms of THD reduction and power injection. The reachable operating point is associated with the inverter output voltage, which is limited by the input dc voltage. Some capabilities, such as reactive power injection, require a high voltage margin. Furthermore, in modern applications, the combination with harmonic capabilities for THD reduction can increase the required voltage leading to extra harmonic pollution. In this paper, a Distortion-Free Instantaneous Multifrequency Saturator (DFIMS) is proposed, which delivers the maximum power in a multifrequency environment, conditioned to the minimum current THD. This novel saturator instantaneously calculates a trajectory that avoids overmodulation at every time step. Simulation and experimental results state the benefits of proposed procedures.
Energy storage systems play a key role in the rise of distributed power generation systems, hence there is great interest in extending their lifetimes, which are directly related to DC current ripple. One of the ripple sources is the low-frequency active power fluctuations under unbalanced and distorted grid voltage conditions. Therefore, this paper addresses a multifrequency control strategy where the harmonic reference currents are calculated to reduce harmonic active power oscillations. The stationary reference frame (StRF) approach taken here improves the precision and computational time of the current reference calculation method. Additionally, in order to ensure safe converter operation when a multifrequency reference current is provided, a computational efficient peak current saturator is applied while avoiding signal distortion every time step. If the injected current harmonic distortion is to be minimized, which is a feature included in this work, the peak current saturator is a necessary requirement. Active power ripple is reduced even with frequency variations in the grid voltage using a well-known frequency-adaptive scheme. The simulation and experimental results prove the optimized performance for the control objective: power ripple reduction with minimum current harmonic distortion.
In recent years, Secondary Substations (SSs) are being provided with equipment that allows their full management. This is particularly useful not only for monitoring and planning purposes but also for detecting erroneous measurements, which could negatively affect the performance of the SS. On the other hand, load forecasting is extremely important since they help electricity companies to make crucial decisions regarding purchasing and generating electric power, load switching, and infrastructure development. In this regard, Short Term Load Forecasting (STLF) allows the electric power load to be predicted over an interval ranging from one hour to one week. However, important issues concerning error detection by employing STLF has not been specifically addressed until now. This paper proposes a novel STLF-based approach to the detection of gain and offset errors introduced by the measurement equipment. The implemented system has been tested against real power load data provided by electricity suppliers. Different gain and offset error levels are successfully detected.
26 May 2017 in IEEE Transactions on Power Electronics
The race to increase the efficiency and reduce the power losses in transmission systems has resulted in the substantial growth of High Voltage Direct Current (HVDC) transmission systems. Moreover, the interconnection of these transmission systems significantly increases their reliability. However, the control of these meshed grids is a key problem that usually is managed through the control of the VSC’s in those grids. But, the control of the VSC can be complemented with a reconfiguration algorithm. This paper proposes the use of the Particle Swarm Optimization (PSO) algorithm, in order to reconfigure meshed High Voltage Direct Current (HVDC) transmission systems and reduce losses. The proposed algorithm has been tested in the CIGRE benchmark grid, which comprises of several offshore wind farms that generate energy sent to the grid through several HVDC transmission lines. The results show that as the energy generation changes due to wind changes, the grid topology must be reconfigured in order to achieve the maximum efficiency. Doing this reconfiguration, power savings around 18-19% could be achieved.
13 November 2018 in IEEE Transactions on Power Electronics
The interest in distributed generators (DGs), especially those associated with renewable energies, has increased in recent years. The number of functionalities that their associated Voltage Source Inverters (VSIs) can deal with is rising, harmonic currents compensation being one of them. VSI control is in charge of accomplishing the different capabilities, and it must be done without exceeding the limited and variable dc voltage margin, if undesirable effects want to be avoided. If limitations are reached, capabilities will be reduced in order to remain within the limitations.