5 April 2010 in IEEE Transactions on Power Delivery
A novel scheme for obtaining the fundamental-frequency positive-sequence grid voltage vector based on a generalization of the delayed signal cancellation method is proposed in this paper. The technique is implemented by sampling and storing the instantaneous αβ voltage vector. A mathematical transformation is then proposed through which the current and delayed voltage vectors are combined. It is shown that the proposed transformation has unity gain for the fundamental-frequency positive-sequence voltage vector, while its gain is equal to zero for some chosen components. Cascaded transformations can then be used for eliminating the fundamental-frequency negative-sequence vector, as well as chosen positive- and negative-sequence harmonic vector components and, thus, for accurately obtaining the fundamental-frequency positive-sequence voltage vector. The output of the last transformation block is input to a synchronous reference frame phase-locked loop for detecting frequency and position of the positive-sequence vector. A proposal for making the scheme frequency adaptive is also presented. The good performance of the proposed method is verified with simulations and experiments by using distorted and unbalanced signals, containing fundamental-frequency as well as positive- and negative-sequence harmonic components. The proposed method frequency adaptation capability is also verified.
24 November 2009 in IEEE Transactions on Industrial Electronics
In this paper, a space-vector discrete-time Fourier transform is proposed for fast and precise detection of the fundamental-frequency and harmonic positive- and negative-sequence vector components of three-phase input signals. The discrete Fourier transform is applied to the three-phase signals represented by Clarke's αβ vector. It is shown that the complex numbers output from the Fourier transform are the instantaneous values of the positive- and negative-sequence harmonic component vectors of the input three-phase signals. The method allows the computation of any desired positive- or negative-sequence fundamental-frequency or harmonic vector component of the input signal. A recursive algorithm for low-effort online implementation is also presented. The detection performance for variable-frequency and interharmonic input signals is discussed. The proposed and other usual method performances are compared through simulations and experiments.
9 March 2018 in IEEE Transactions on Industrial Electronics
This paper combines the well-known linear quadratic Gaussian (LQG) control and frequency-adaptive resonators and presents a frequency-adaptive multiresonant LQG state-feedback current controller for LCL-filtered voltage-source converters connected to a distorted grid. The paper also provides a design guideline and procedure based on robust control criteria, which, in combination with the linear quadratic regulator technique, offers flexibility in the control structure and automatizes the design of the controller. The frequency-adaptive resonators, based on second-order IIR resonators and on an online tuning algorithm, and the robustness criteria considered for the design process offer robustness in the face of grid voltage disturbances. The controller is evaluated and validated in a 9-kVA voltage-source converter (VSC) setup configured as a rectifier.
23 March 2021 in IEEE Transactions on Power Electronics
This article presents a systematic robust current control design approach for three-phase voltage-source converters. Robustness is guaranteed by combining intrinsic passive properties of the impedance uncertainty at the point of common coupling together with stability results from a passivity-based control theory. This approach ensures stability against typical uncertainty sources at mid and high frequencies, such as cable resonances or other converters interaction, with significant less conservative performances than the obtained with the traditional robust control theory. The approach uses multiobjective controller synthesis formulation that allows us to logically combine robustness requirements with performance objectives avoiding heuristic iteration over the control structure and parameters. The controller synthesis is performed by means of a nonsmooth $\mathcal {H}_{\infty }$ optimization technique that tunes all free parameters of a vector-based controller function, which constraints its structure. This results in a synthesized controller with lower order than those obtained with convex optimization definitions of the $\mathcal {H}_{\infty }$ control problem. The design methodology is validated in time and frequency domain by means of theoretical analysis and experimental results with three usual grid filters: L , LCL, and LLCL .
30 April 2018 in IEEE Transactions on Power Electronics
Three-Level Neutral-Point-Clamped Voltage-Source-Converter (3L-NPC-VSC) is widely used in high-power and Medium-Voltage (MV) applications and the most used multilevel VSC topology. 3L-Active-NPC-VSC (3L-ANPC-VSC) was introduced to overcome the unequal losses distribution as main structural drawback of the 3L-NPC-VSC. During the switching event of semiconductor devices, the stray inductance takes a special role in the commutation path of the switching current. Mutual coupling inductance between the components participating in the commutation path has to be considered for a theoretical assessment of the total stray inductance of each commutation path. Besides, the measurement of the commutation path stray inductance has to be carried out during the turn-on of the semiconductor device, instead of during the turn-off, to consider the reverse blocking voltage of the opposite switching semiconductor device. This paper shows how a dual 3L-ANPC-VSC phase-leg has been carefully designed and assembled to build a $\pm$10 MVAr Five-Level VSC for MV -static synchronous compensator (MV-STATCOM) applications. All the analysis details of the 3L-ANPC-VSC commutation behavior using 4.5 kV and 1.5 kA Trench High-Voltage (HV) -IGBT modules are presented.
12 June 2014 in IEEE Transactions on Power Electronics
Voltage controlled voltage source converters (VCVSC) and current controlled voltage source converters (CCVSC) have gained importance within distributed power generation systems and equipment for power quality improvement. The control action is susceptible to fall in saturation under disturbance transients or in case of poor control tuning. The use of existing saturation techniques for vector variables, such as three-phase voltage and current, distorts the reference waveforms under unbalanced conditions regardless the used reference frames--stationary (αβ-axis) or synchronous (dq-axis). These harmonics are quite detrimental for the electric grid and reduce the efficiency. This paper presents a distortion-free saturation methodology with two versions and analyzes the performance in function of the control structure (VCVSC and CCVSC) and the saturation point within the control loop. The experimental results prove the advantages of using the proposed saturators.