Andrzej Tutaj

Dr. Andrzej Tutaj

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2017 in AEU - International Journal of Electronics and Communications
Verified
Journal Article
Closed access
Jerzy BaranowskiJerzy Baranowski
Jerzy Baranowski
MPMariusz Pauluk
Mariusz Pauluk
ATAndrzej Tutaj
Andrzej Tutaj

12 April 2021 in Energies
Verified
Journal Article
Open access
PDF file
Jerzy BaranowskiJerzy Baranowski
Jerzy Baranowski
Tomasz DrabekTomasz Drabek
Tomasz Drabek
Paweł PiątekPaweł Piątek
Paweł Piątek
ATAndrzej Tutaj
Andrzej Tutaj
Electrical devices in the consumer markets need to comply with stringent standards for electromagnetic interference (EMI) distortion and electromagnetic compatibility (EMC). This paper presents the results of measurements of electromagnetic interference generated by an electrical drive of an electric torque tool with a brushless DC motor. The measurements were made in accordance with the PN-EN 55014-1:2017-06E standard, in the frequency band of 148 kHz–30 MHz. The results confirmed that the tested drive can meet the requirements defined in this document. Another document, the PN-EN IEC 61000-3-2:2019-04E standard, provides limits for the harmonic content in the current drawn by electrical devices from a single-phase AC line. This paper also presents the results of measurements related to this standard. Harmonics, up to and including the 40th one, were determined and compared with the limits given in the standard for class B devices. The measurement results indicate a need to use an active power factor corrector (PFC) filter. Such a system has been tested by computer simulations. The results confirmed its ability to meet the requirements of relevant standards.

15 May 2021 in Fractal and Fractional
Verified
Journal Article
Open access
PDF file
Evisa MemlikaiEvisa Memlikai
Evisa Memlikai
Stavroula KapouleaStavroula Kapoulea
Stavroula Kapoulea
Costas PsychalinosCostas Psychalinos
Costas Psychalinos
Jerzy BaranowskiJerzy Baranowski
Jerzy Baranowski
Waldemar BauerWaldemar Bauer
Waldemar Bauer
Paweł PiątekPaweł Piątek
Paweł Piątek
An alternative procedure for the implementation of fractional-order compensators is presented in this work. The employment of a curve-fitting-based approximation technique for the approximation of the compensator transfer function offers improved accuracy compared to the Oustaloup and Padé methods. As a design example, a lead compensator intended for usage in car suspension systems is realized. The open-loop and closed-loop behavior of the system is evaluated by post-layout simulation results obtained using the Cadence IC design suite and the Metal Oxide Semiconductor (MOS) transistor models provided by the Austria Mikro Systeme 0.35 μm Complementary Metal Oxide Semiconductor (CMOS) process. The derived results verify the efficient performance of the introduced implementation.

1 January 2015 in International Journal of Modeling and Optimization
Verified
Journal Article
Closed access
WGWojciech Grega
Wojciech Grega
APAdam Pilat
Adam Pilat
ATAndrzej Tutaj
Andrzej Tutaj

1 September 2019 in Clinical Neurology and Neurosurgery
Verified
Journal Article
Closed access
AWAgata Walczak
Agata Walczak
IKIwona Kurkowska-Jastrzebska
Iwona Kurkowska-Jastrzebska
BZBeata Zakrzewska-Pniewska
Beata Zakrzewska-Pniewska
MDMałgorzata W Dorobek
Małgorzata W Dorobek
WBWaldemar Brola
Waldemar Brola
ASAdam Stepien
Adam Stepien

20 October 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
PZPawel Zagorski
Pawel Zagorski
DKDawid Knapik
Dawid Knapik
KKKrzysztof Kołek
Krzysztof Kołek
MRMaciej Rosół
Maciej Rosół
ATAndrzej Tutaj
Andrzej Tutaj
AGAlberto Gallina
Alberto Gallina
This work presents a validation process of a Helmholtz cage developed by the authors at AGH University of Krakow. This type of test stand can generate a near-uniform, precisely controlled magnetic field inside its workspace. This is a crucial tool for several applications, including calibration of magnetic sensors, testing magnetorquers, and hardware-in-the-loop tests of attitude determination and control systems of small satellites. Although many institutions develop Helmholtz cages, we found the literature on methods of validating the final accuracy and uniformity of the generated magnetic field somewhat lacking. In this research, we showcase an approach to perform 3D scans of the magnetic field inside the cage using a probe actuated by a robotic arm. With that method, we verified that the magnitude and angle nonuniformity of the magnetic field vectors in our cage are below 2 percent and 0.4°, respectively, for a wide range of control inputs. We also perform background magnetic field measurements to identify and quantify sources of magnetic disturbances coming from the outside of our system and propose methods of minimizing their impact. It turns out that careful design and building process of the cage and its power driver might not be sufficient to achieve the optimal performance. In our case, we found that some factors, if unmitigated, can cause an error of a few milligauss. Hopefully, this work will help other teams developing similar devices avoid at least some of the possible pitfalls.