To generate high-resolution maps of the viscoelastic properties of human brain parenchyma for presurgical quantitative assessment in glioblastoma (GB). Twenty-two GB patients underwent routine presurgical work-up supplemented by additional multifrequency magnetic resonance elastography. Two three-dimensional viscoelastic parameter maps, magnitude |G*|, and phase angle φ of the complex shear modulus were reconstructed by inversion of full wave field data in 2-mm isotropic resolution at seven harmonic drive frequencies ranging from 30 to 60 Hz. Mechanical brain maps confirmed that GB are composed of stiff and soft compartments, resulting in high intratumor heterogeneity. GB could be easily differentiated from healthy reference tissue by their reduced viscous behavior quantified by φ (0.37±0.08 vs. 0.58±0.07). |G*|, which in solids more relates to the material's stiffness, was significantly reduced in GB with a mean value of 1.32±0.26 kPa compared to 1.54±0.27 kPa in healthy tissue (P = 0.001). However, some GB (5 of 22) showed increased stiffness. GB are generally less viscous and softer than healthy brain parenchyma. Unrelated to the morphology-based contrast of standard magnetic resonance imaging, elastography provides an entirely new neuroradiological marker and contrast related to the biomechanical properties of tumors.
14 February 2013 in Magnetic Resonance in Medicine
Cerebral viscoelastic constants can be measured in a noninvasive, image-based way by magnetic resonance elastography (MRE) for the detection of neurological disorders. However, MRE brain maps of viscoelastic constants are still limited by low spatial resolution. Here we introduce three-dimensional multifrequency MRE of the brain combined with a novel reconstruction algorithm based on a model-free multifrequency inversion for calculating spatially resolved viscoelastic parameter maps of the human brain corresponding to the dynamic range of shear oscillations between 30 and 60 Hz. Maps of two viscoelastic parameters, the magnitude and the phase angle of the complex shear modulus, |G*| and φ, were obtained and normalized to group templates of 23 healthy volunteers in the age range of 22 to 72 years. This atlas of the anatomy of brain mechanics reveals a significant contrast in the stiffness parameter |G*| between different anatomical regions such as white matter (WM; 1.252±0.260 kPa), the corpus callosum genu (CCG; 1.104±0.280 kPa), the thalamus (TH; 1.058±0.208 kPa) and the head of the caudate nucleus (HCN; 0.649±0.101 kPa). φ, which is sensitive to the lossy behavior of the tissue, was in the order of CCG (1.011±0.172), TH (1.037±0.173), CN (0.906±0.257) and WM (0.854±0.169). The proposed method provides the first normalized maps of brain viscoelasticity with anatomical details in subcortical regions and provides useful background data for clinical applications of cerebral MRE.
Patients with increased liver stiffness have a higher risk of developing cancer, however, the role of fluid–solid tissue interactions and their contribution to liver tumor malignancy remains elusive. Tomoelastography is a novel imaging method for mapping quantitatively the solid–fluid tissue properties of soft tissues in vivo. It provides high resolution and thus has clear clinical applications. In this work we used tomoelastography in 77 participants, with a total of 141 focal liver lesions of different etiologies, to investigate the contributions of tissue stiffness and fluidity to the malignancy of liver tumors. Shear-wave speed (c) as surrogate for tissue stiffness and phase-angle (φ) of the complex shear modulus reflecting tissue fluidity were abnormally high in malignant tumors and allowed them to be distinguished from nontumorous liver tissue with high accuracy [c: AUC = 0.88 with 95% confidence interval (CI) = 0.83–0.94; φ: AUC = 0.95, 95% CI = 0.92–0.98]. Benign focal nodular hyperplasia and hepatocellular adenoma could be distinguished from malignant lesions on the basis of tumor stiffness (AUC = 0.85, 95% CI = 0.72–0.98; sensitivity = 94%, 95% CI = 89–100; and specificity = 85%, 95% CI = 62–100), tumor fluidity (AUC = 0.86, 95% CI = 0.77–0.96; sensitivity = 83%, 95% CI = 72–93; and specificity = 92%, 95% CI = 77–100) and liver stiffness (AUC = 0.84, 95% CI = 0.74–0.94; sensitivity = 72%, 95% CI = 59–83; and specificity = 88%, 95% CI = 69–100), but not on the basis of liver fluidity. Together, hepatic malignancies are characterized by stiff, yet fluid tissue properties, whereas surrounding nontumorous tissue is dominated by solid properties. Tomoelastography can inform noninvasively on the malignancy of suspicious liver lesions by differentiating between benign and malignant lesions with high sensitivity based on stiffness and with high specificity based on fluidity. Significance: Solid–fluid tissue properties measured by tomoelastography can distinguish malignant from benign masses with high accuracy and provide quantitative noninvasive imaging biomarkers for liver tumors.
Purpose: To demonstrate the feasibility of in vivo wideband MR elastography (wMRE) using continuous, time‐harmonic shear vibrations in the frequency range of 10–50 Hz.Theory and Methods: The method was tested in a gel phantom with marked mechanical loss. The brains and livers of eight volunteers were scanned by wMRE using multislice, single‐shot MRE with optimized fractional encoding and synchronization of sequence acquisition to vibration. Multifrequency three‐dimensional inversion was used to reconstruct compound maps of magnitude |G*| and phase φ of the complex shear modulus. A new phase estimation, φ*, was developed to avoid systematic bias due to noise.Results: In the phantom, G*‐dispersion measured by wMRE agreed well with oscillatory shear rheometry. |G*| and φ* measured at vibrations of 10–25 HZ, 25–35 HZ, and 40–50 HZ were 0.62 ± 0.08, 1.56 ± 0.16, 2.18 ± 0.20 kPa and 0.09 ± 0.17, 0.39 ± 0.16, 0.20 ± 0.13 rad in brain and 0.89 ± 0.11, 1.67 ± 0.20, 2.27 ± 0.35 kPa and 0.15 ± 0.10, 0.24 ± 0.05, 0.26 ± 0.05 rad in liver. Elastograms including all frequencies showed the best resolution of anatomical detail with |G*| = 1.38 ± 0.12 kPa, φ* = 0.24 ± 0.10 rad (brain) and |G*| = 1.79 ± 0.23 kPa, φ* = 0.24 ± 0.05 rad (liver).Conclusion: wMRE reveals highly dispersive G* properties of the brain and liver, and our results suggest that the influence of large‐scale structures such as fluid‐filled vessels and sulci on the MRE‐measured parameters increases at low vibration frequencies. Magn Reson Med 76:1116–1126, 2016.