Mehrgan Shahryari

Mehrgan Shahryari

Auto-generated profile, based on publicly available information

Mehrgan Shahryari

Department of Radiology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 November 2019 in Cancer Research
Verified
Journal Article
Closed access
PDF file
MSMehrgan Shahryari
Mehrgan Shahryari
HTHeiko Tzschätzsch
Heiko Tzschätzsch
JGJing Guo
Jing Guo
SGStephan R. Marticorena Garcia
Stephan R. Marticorena Garcia
GBGeorg Böning
Georg Böning
ISIngolf Sack
Ingolf Sack
Patients with increased liver stiffness have a higher risk of developing cancer, however, the role of fluid–solid tissue interactions and their contribution to liver tumor malignancy remains elusive. Tomoelastography is a novel imaging method for mapping quantitatively the solid–fluid tissue properties of soft tissues in vivo. It provides high resolution and thus has clear clinical applications. In this work we used tomoelastography in 77 participants, with a total of 141 focal liver lesions of different etiologies, to investigate the contributions of tissue stiffness and fluidity to the malignancy of liver tumors. Shear-wave speed (c) as surrogate for tissue stiffness and phase-angle (φ) of the complex shear modulus reflecting tissue fluidity were abnormally high in malignant tumors and allowed them to be distinguished from nontumorous liver tissue with high accuracy [c: AUC = 0.88 with 95% confidence interval (CI) = 0.83–0.94; φ: AUC = 0.95, 95% CI = 0.92–0.98]. Benign focal nodular hyperplasia and hepatocellular adenoma could be distinguished from malignant lesions on the basis of tumor stiffness (AUC = 0.85, 95% CI = 0.72–0.98; sensitivity = 94%, 95% CI = 89–100; and specificity = 85%, 95% CI = 62–100), tumor fluidity (AUC = 0.86, 95% CI = 0.77–0.96; sensitivity = 83%, 95% CI = 72–93; and specificity = 92%, 95% CI = 77–100) and liver stiffness (AUC = 0.84, 95% CI = 0.74–0.94; sensitivity = 72%, 95% CI = 59–83; and specificity = 88%, 95% CI = 69–100), but not on the basis of liver fluidity. Together, hepatic malignancies are characterized by stiff, yet fluid tissue properties, whereas surrounding nontumorous tissue is dominated by solid properties. Tomoelastography can inform noninvasively on the malignancy of suspicious liver lesions by differentiating between benign and malignant lesions with high sensitivity based on stiffness and with high specificity based on fluidity. Significance: Solid–fluid tissue properties measured by tomoelastography can distinguish malignant from benign masses with high accuracy and provide quantitative noninvasive imaging biomarkers for liver tumors.

8 August 2023 in Advanced Science
Verified
Journal Article
Open access
FSFrank Sauer
Frank Sauer
SGSteffen Grosser
Steffen Grosser
MSMehrgan Shahryari
Mehrgan Shahryari
AHAlexander Hayn
Alexander Hayn
JGJing Guo
Jing Guo
JKJosef Alfons Käs
Josef Alfons Käs
Cancer progression is caused by genetic changes and associated with various alterations in cell properties, which also affect a tumor's mechanical state. While an increasedstiffnesshas been well known for long for solid tumors, it has limited prognostic power. It is hypothesized that cancer progression is accompanied by tissuefluidization, where portions of the tissue can change position across different length scales. Supported by tabletop magnetic resonance elastography (MRE) on stroma mimicking collagen gels and microscopic analysis of live cells inside patient derived tumor explants, an overview is provided of how cancer associated mechanisms, including cellular unjamming, proliferation, microenvironment composition, and remodeling can alter a tissue'sfluidityandstiffness. In vivo, state‐of‐the‐art multifrequency MRE can distinguish tumors from their surrounding host tissue by their rheological fingerprints. Most importantly, a meta‐analysis on the currently available clinical studies is conducted and universal trends are identified. The results and conclusions are condensed into a gedankenexperiment about how a tumor can grow and eventually metastasize into its environment from a physics perspective to deduce corresponding mechanical properties. Based onstiffness, fluidity,spatial heterogeneity, andtextureof thetumor fronta roadmap for a prognosis of a tumor's aggressiveness and metastatic potential is presented.

12 June 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
TMTom Meyer
Tom Meyer
SGStephan Marticorena Garcia
Stephan Marticorena Garcia
HTHeiko Tzschätzsch
Heiko Tzschätzsch
HHHelge Herthum
Helge Herthum
MSMehrgan Shahryari
Mehrgan Shahryari
ISIngolf Sack
Ingolf Sack
Purpose: Magnetic resonance elastography (MRE) maps the viscoelastic properties of soft tissues for diagnostic purposes. However, different MRE inversion methods yield different results, which hinder comparison of values, standardization, and establishment of quantitative MRE markers. Here, we introduce an expandable, open‐access, webserver‐based platform that offers multiple inversion techniques for multifrequency, 3D MRE data.Methods: The platform comprises a data repository and standard MRE inversion methods including local frequency estimation (LFE), direct‐inversion based multifrequency dual elasto‐visco (MDEV) inversion, and wavenumber‐based (k‐) MDEV. The use of the platform is demonstrated in phantom data and in vivo multifrequency MRE data of the kidneys and brains of healthy volunteers.Results: Detailed maps of stiffness were generated by all inversion methods showing similar detail of anatomy. Specifically, the inner renal cortex had higher shear wave speed (SWS) than renal medulla and outer cortex without lateral differences.k‐MDEV yielded higher SWS values than MDEV or LFE (full kidney/braink‐MDEV: 2.71 ± 0.19/1.45 ± 0.14 m/s, MDEV: 2.14 ± 0.16/0.99 ± 0.11 m/s, LFE: 2.12 ± 0.15/0.89 ± 0.06 m/s).Conclusion: The freely accessible platform supports the comparison of MRE results obtained with different inversion methods, filter thresholds, or excitation frequencies, promoting reproducibility in MRE across community‐developed methods.

26 October 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
MSMehrgan Shahryari
Mehrgan Shahryari
TMTom Meyer
Tom Meyer
CWCarsten Warmuth
Carsten Warmuth
HHHelge Herthum
Helge Herthum
GBGergely Bertalan
Gergely Bertalan
ISIngolf Sack
Ingolf Sack
Purpose: With abdominal magnetic resonance elastography (MRE) often suffering from breathing artifacts, it is recommended to perform MRE during breath‐hold. However, breath‐hold acquisition prohibits extended multifrequency MRE examinations and yields inconsistent results when patients cannot hold their breath. The purpose of this work was to analyze free‐breathing strategies in multifrequency MRE of abdominal organs.Methods: Abdominal MRE with 30, 40, 50, and 60 Hz vibration frequencies and single‐shot, multislice, full wave‐field acquisition was performed four times in 11 healthy volunteers: once with multiple breath‐holds and three times during free breathing with ungated, gated, and navigated slice adjustment. Shear wave speed maps were generated by tomoelastography inversion. Image registration was applied for correction of intrascan misregistration of image slices. Sharpness of features was quantified by the variance of the Laplacian.Results: Total scan times ranged from 120 seconds for ungated free‐breathing MRE to 376 seconds for breath‐hold examinations. As expected, free‐breathing MRE resulted in larger organ displacements (liver, 4.7 ± 1.5 mm; kidneys, 2.4 ± 2.2 mm; spleen, 3.1 ± 2.4 mm; pancreas, 3.4 ± 1.4 mm) than breath‐hold MRE (liver, 0.7 ± 0.2 mm; kidneys, 0.4 ± 0.2 mm; spleen, 0.5 ± 0.2 mm; pancreas, 0.7 ± 0.5 mm). Nonetheless, breathing‐related displacement did not affect mean shear wave speed, which was consistent across all protocols (liver, 1.43 ± 0.07 m/s; kidneys, 2.35 ± 0.21 m/s; spleen, 2.02 ± 0.15 m/s; pancreas, 1.39 ± 0.15 m/s). Image registration before inversion improved the quality of free‐breathing examinations, yielding no differences in image sharpness to uncorrected breath‐hold MRE in most organs (P> .05).Conclusion: Overall, multifrequency MRE is robust to breathing when considering whole‐organ values. Respiration‐related blurring can readily be corrected using image registration. Consequently, ungated free‐breathing MRE combined with image registration is recommended for multifrequency MRE of abdominal organs.

1 February 2021 in Acta Biomaterialia
Verified
Journal Article
Closed access
HHHelge Herthum
Helge Herthum
SDSergio C H Dempsey
Sergio C H Dempsey
ASAbbas Samani
Abbas Samani
FSFelix Schrank
Felix Schrank
MSMehrgan Shahryari
Mehrgan Shahryari
ISIngolf Sack
Ingolf Sack

1 September 2021 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
RRRolf Reiter
Rolf Reiter
MSMehrgan Shahryari
Mehrgan Shahryari
HTHeiko Tzschätzsch
Heiko Tzschätzsch
MHMatthias Haas
Matthias Haas
CBChristian Bayerl
Christian Bayerl
ISIngolf Sack
Ingolf Sack