With the increasing global requirements for environmental protection, refrigerants with ODP of 0 and low GWP are widely concerned and applied. In this paper, the CFD numerical method simulates the R134a centrifugal compressor directly replaced by R1234yf and R1234ze(E). The results show that at the same compressor rotational speed, using R1234yf to replace R134a directly can obtain a higher cooling capacity, but it reduces COP by about 12.5%; using R1234ze(E) to replace R134a directly reduces the cooling capacity under partial working conditions, the COP is reduced by about 7.0%. When the evaporation temperature, condensation temperature, and cooling capacity are the same, compared with the R134a unit, the COP of the R1234ze(E) unit is reduced by about 5.14%, and it is reduced by about 8.93% for the R1234yf unit. For the R134a centrifugal chiller, the drop-in replacement of R134a with R1234ze(E) can obtain better system performance compared with R1234yf.
Because of the limitations of traditional refrigerants, the application of trans-critical CO2 technology in domestic gas conditioners and other fields is becoming increasingly popular. This paper proposes a new CO2 trans-critical refrigeration system. Combining the internal heat exchanger and expander components, as well as the two-stage compression cycle, we analyzed the effectiveness of the expander, internal heat exchanger, and intercooling on system performance under various operating conditions in terms of energy, exergy analysis, and optimal discharge pressure. The system performance can be changed by changing the cycle conditions and internal heat exchanger effectiveness, which reduces system power consumption and the percentage of exergy losses of gas cooler components. Compared to the single-stage compression with expander cycle, the systems cycle power consumption is reduced by 2–15.7% and the maximum system COP is increased by 2.93–6.93%. From the view of energy effectiveness, the system’s maximum COP increases by 3.9% and the percentage of exergy losses of gas cooler decreases by 22.5% with the effectiveness of internal heat exchanger varying. The addition of an internal heat exchanger has resulted in improved system performance, which is important for providing a relevant cycle model for the application.
1 February 2020 in Desalination and Water Treatment
The performance of an externally pressurized gas journal bearing lubricated with R134a vapor used in an oil-free refrigeration centrifugal compressor is calculated by solving Reynold equations with the finite difference method (CFD). The load capacity, stiffness and mass flow rate of refrigerant vapor under conditions of various operational parameters are obtained and compared with that in air gas bearings. In addition, the influences of the average clearance, eccentricity ratios and supply vapor pressure on the static characteristics of journal bearings are investigated and discussed in detail. It concluded that the optimal operation parameters of gas journal bearings lubricated with R134a vapor are different with air journal bearings. These factors should be considered in the design process of R134a refrigerant vapor gas journal bearings.
In this study, a three-dimensional model with actual clearances was established for a scroll oil pump, and the internal flow was simulated by the CFD method. The internal flows at different rotation angles were studied, and the cavitation and pressure pulsation in the scroll pump under different working conditions were analyzed. The results show that the flow in the two working chambers of the scroll pump is asymmetric due to its structural characteristics and motion mode. The high-pressure pulsation occurs in the working chamber during the end of the suction and the beginning of discharge. Under the action of high-pressure difference, there is a high-speed jet in the clearance between the orbiting and fixed scrolls, which causes a large area of cavitation downstream of the clearance. Under a low suction pressure, cavitation intensifies with the increase in rotating speed, which leads to a decrease in volumetric efficiency. It can effectively improve cavitation by increasing the suction pressure and volumetric efficiency of the pump. The pressure pulsation can be effectively improved by increasing the axial clearance and reducing the rotating speed. The method of reducing pressure pulsation by shortening the scroll profile is proposed.