Guangbin Liu

Guangbin Liu

Auto-generated profile, based on publicly available information

Guangbin Liu

College of Electromechanical Engineering, Qingdao University of Science and Technology, Qingdao 266100, China

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 March 2022 in Energies
Verified
Journal Article
Open access
PDF file
KYKexin Yi
Kexin Yi
YZYuanyang Zhao
Yuanyang Zhao
GLGuangbin Liu
Guangbin Liu
QYQichao Yang
Qichao Yang
YGYu Guoxin
Yu Guoxin
LLLiansheng LI
Liansheng LI
With the increasing global requirements for environmental protection, refrigerants with ODP of 0 and low GWP are widely concerned and applied. In this paper, the CFD numerical method simulates the R134a centrifugal compressor directly replaced by R1234yf and R1234ze(E). The results show that at the same compressor rotational speed, using R1234yf to replace R134a directly can obtain a higher cooling capacity, but it reduces COP by about 12.5%; using R1234ze(E) to replace R134a directly reduces the cooling capacity under partial working conditions, the COP is reduced by about 7.0%. When the evaporation temperature, condensation temperature, and cooling capacity are the same, compared with the R134a unit, the COP of the R1234ze(E) unit is reduced by about 5.14%, and it is reduced by about 8.93% for the R1234yf unit. For the R134a centrifugal chiller, the drop-in replacement of R134a with R1234ze(E) can obtain better system performance compared with R1234yf.

22 December 2022 in Energies
Verified
Journal Article
Open access
PDF file
BSbenlin shi
benlin shi
MCMuqing Chen
Muqing Chen
WCWeikai Chi
Weikai Chi
QYQichao Yang
Qichao Yang
GLGuangbin Liu
Guangbin Liu
LLLiansheng LI
Liansheng LI
Because of the limitations of traditional refrigerants, the application of trans-critical CO2 technology in domestic gas conditioners and other fields is becoming increasingly popular. This paper proposes a new CO2 trans-critical refrigeration system. Combining the internal heat exchanger and expander components, as well as the two-stage compression cycle, we analyzed the effectiveness of the expander, internal heat exchanger, and intercooling on system performance under various operating conditions in terms of energy, exergy analysis, and optimal discharge pressure. The system performance can be changed by changing the cycle conditions and internal heat exchanger effectiveness, which reduces system power consumption and the percentage of exergy losses of gas cooler components. Compared to the single-stage compression with expander cycle, the systems cycle power consumption is reduced by 2–15.7% and the maximum system COP is increased by 2.93–6.93%. From the view of energy effectiveness, the system’s maximum COP increases by 3.9% and the percentage of exergy losses of gas cooler decreases by 22.5% with the effectiveness of internal heat exchanger varying. The addition of an internal heat exchanger has resulted in improved system performance, which is important for providing a relevant cycle model for the application.

1 February 2020 in Desalination and Water Treatment
Verified
Journal Article
Open access
GLGuangbin Liu
Guangbin Liu
XZXiaoyan Zhao
Xiaoyan Zhao
QYQichao Yang
Qichao Yang
YZYuanyang Zhao
Yuanyang Zhao
BTBin Tang
Bin Tang
LWLe Wang
Le Wang

23 September 2021 in Processes
Verified
Journal Article
Open access
PDF file
STSugen Tian
Sugen Tian
YZYuanyang Zhao
Yuanyang Zhao
KDKairui Dong
Kairui Dong
GLGuangbin Liu
Guangbin Liu
QYQichao Yang
Qichao Yang
LLLiansheng LI
Liansheng LI
In this study, a three-dimensional model with actual clearances was established for a scroll oil pump, and the internal flow was simulated by the CFD method. The internal flows at different rotation angles were studied, and the cavitation and pressure pulsation in the scroll pump under different working conditions were analyzed. The results show that the flow in the two working chambers of the scroll pump is asymmetric due to its structural characteristics and motion mode. The high-pressure pulsation occurs in the working chamber during the end of the suction and the beginning of discharge. Under the action of high-pressure difference, there is a high-speed jet in the clearance between the orbiting and fixed scrolls, which causes a large area of cavitation downstream of the clearance. Under a low suction pressure, cavitation intensifies with the increase in rotating speed, which leads to a decrease in volumetric efficiency. It can effectively improve cavitation by increasing the suction pressure and volumetric efficiency of the pump. The pressure pulsation can be effectively improved by increasing the axial clearance and reducing the rotating speed. The method of reducing pressure pulsation by shortening the scroll profile is proposed.

1 August 2019 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
GLGuangbin Liu
Guangbin Liu
XZXiaoyan Zhao
Xiaoyan Zhao
LLLi Liansheng
Li Liansheng
TBTang Bin
Tang Bin
QYQichao Yang
Qichao Yang
ZYZhao Yuanyang
Zhao Yuanyang
Screw compressor is suitable for small scale mechanical vapor recompression (MVR) system especially for the solution with high boiling point elevation. In this paper, a mathematical model of screw compressor in MVR system is built and its working process is simulated. The results show that water injection improves the efficiency of screw compressor obviously and the compression process along saturated vapor line is realized if enough water is injected. The volumetric and isentropic efficiency is not sensitive with the water if more than flow rate of 35L/h is injected. The discharge temperature decreases from 133.4°C to 108°C with water quantities of 5L/h to 35L/h and then it is constant . The large saturated heat transfer difference in evaporator leads to decrement of volumetric efficiency but increment of isentropic efficiency. The mass flow rate of distilled water increase from 0.38t/h to 2.56 t/h and the saturated temperature difference increases from 4°C to 26.9°C when the rotating speed increases from 1000 rpm to 6000rpm.