The prosthetic feet that are most often prescribed to individuals with K3/K4 levels of ambulation are the ESR feet. ESR stands for energy-storing and -releasing. The elastic energy is stored by the elastic elements in composite materials (carbon fiber or glass fiber). ESR feet must be developed and optimized in terms of stiffness, taking into account the loads that a healthy human foot undergoes and its kinematics while walking. So far, state-of-the-art analyses show that the literature approaches for prosthetic foot design are not based on a systematic methodology. With the aim of optimizing the stiffness of ESR feet following a methodological procedure, a methodology based on finite element structural analysis, standard static testing (ISO 10328) and functional verification was optimized and it is presented in this paper. During the path of optimization of the foot prototypes, this methodology was validated experimentally. It includes the following: (i) geometry optimization through two-dimensional finite element analysis; (ii) material properties optimization through three-dimensional finite element analysis; (iii) validation test on physical prototypes; (iv) functionality verification through dynamic finite element analysis. The design and functional verification of MyFlex-, a three-blade ESR foot prosthesis, is presented to describe the methodology and demonstrate its usability.
Most biomechanical research has focused on level-ground walking giving less attention to other conditions. As a result, most lower limb prosthesis studies have focused on sagittal plane movements. In this paper, an ESR foot is presented, of which five different stiffnesses were optimized for as many weight categories of users. It is characterized by a spherical ankle joint, with which, combined with the elastic elements, the authors wanted to create a prosthesis that gives the desired stiffness in the sagittal plane but at the same time, gives flexibility in the other planes to allow the adaptation of the foot prosthesis to the ground conditions. The ESR foot was preliminarily tested by participants with transfemoral amputation. After a brief familiarization with the device, each participant was asked to wear markers and to walk on a sensorized treadmill to measure their kinematics and kinetics. Then, each participant was asked to leave feedback via an evaluation questionnaire. The measurements and feedback allowed us to evaluate the performance of the prosthesis quantitatively and qualitatively. Although there were no significant improvements on the symmetry of the gait, due also to very limited familiarization time, the participants perceived an improvement brought by the spherical ankle joint.
24 January 2025 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Most commercially available foot prostheses are passive ESR feet, which store and release energy to reduce metabolic costs and improve comfort but cannot adjust to varying walking conditions. In contrast, bionic feet adapt to different tasks but are hindered by high weight, power consumption, and cost. This paper presents MyFlex-ζ, an ESR foot with a variable stiffness system, as a compromise between these two categories. MyFlex-ζ adjusts stiffness by varying the sagittal-plane distance between two key points, altering force interactions within the prosthesis and affecting overall stiffness. Clinical tests with three transfemoral amputees evaluated stiffness variation across two sessions: the first subjective, where participants assessed stiffness settings during different tasks, and the second biomechanical, measuring performance parameters. Two participants selected different stiffness settings for various tasks, while the third, with limited perception of stiffness changes, showed less distinction in outcomes. Greater sagittal-plane rotation and higher energy absorption were observed in most tasks with more compliant settings, although one participant’s results were limited due to selecting close stiffness settings. Overall, these findings suggest MyFlex-ζ offers adaptability and performance improvements over traditional ESR feet. With further actuation and control system development, MyFlex-ζ could mark significant progress in prosthesis technology.
1 January 2025 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Improper tuning of prosthetic foot properties to the individual user limits the efficacy of current state-of-the-art prosthetic feet in terms of walking economy. This study aims to explore the potential of human-in-the-loop optimization to individually optimize prosthetic foot stiffness and alignment to decrease the metabolic cost of walking of transtibial amputees. 10 transtibial amputees underwent an optimization protocol while walking on a treadmill with an experimental prosthetic foot with tuneable stiffness and alignment. We aimed to minimize the metabolic cost of walking by optimizing the stiffness and alignment of the prosthetic foot, using an evolutionary optimization algorithm. The metabolic cost of walking during the post-test using optimal settings was compared with the pre-test using standard settings, and the post-test using standard settings. Human-in-the-loop optimization of the tuneable prosthetic foot resulted in optimal stiffness (4.41 ± 0.17 Nm/°) and alignment (2.40 ± 0.97°) settings that differ between participants. Walking on the prosthetic foot with optimized settings during the post-test resulted in a significant reduction in metabolic cost compared to the pre-test with standard settings (-10.6%). The metabolic cost during the post-test with standard settings was in between the pre-test with standard settings (-6.6%) and the post-test with optimal settings (-4.3%), indicating that part of the decrease in cost could be explained by motor adaptation of the user. Human-in-the-loop optimization can individually tune the stiffness and alignment of a prosthetic foot to lower the metabolic cost of walking for transtibial amputees and provides different optimal settings for each individual participant. Both optimization of prosthetic components and motor adaptation of the user contributed to the reduction in metabolic cost, which corroborates that human-in-the-loop optimization could enhance the efficacy of prosthetic devices.
The ankle joint is pivotal in prosthetic feet, especially in Energy-Storing-and-Releasing feet, favoured by individuals with moderate to high mobility (K3/K4) due to their energy efficiency and simple construction. ESR feet, mainly designed for sagittal-plane motion, often exhibit high stiffness in other planes, leading to difficulties in adapting to varied ground conditions, potentially causing discomfort or pain. This study aims to present a systematic methodology for modifying the ankle joint’s stiffness properties across its three motion planes, tailored to individual user preferences, and to decouple the sagittal-plane behaviour from the frontal and transverse ones. To integrate the multi-axial ankle inside the MyFlex-η, the designing of experiments using finite element analysis was conducted to explore the impact of geometric parameters on the joint’s properties with respect to design constraints and to reach the defined stiffness targets on the three ankle’s motion planes. A prototype of the multi-axial ankle joint was then manufactured and tested under FEA-derived load conditions to validate the final configuration chosen. Composite elastic elements and complementary parts of the MyFlex-η, incorporating the multi-axial ankle joint, were developed, and the prosthesis was biomechanically tested according to lower limb prosthesis ISO standards and guidelines from literature and the American Orthotic and Prosthetic Association (AOPA). Experimental tests showed strong alignment with numerical predictions. Moreover, implementing the multi-axial ankle significantly increased frontal-plane compliance by 414% with respect to the same prosthesis with only one degree of freedom on the sagittal plane without affecting the main plane of locomotion performance.
In this article, MyFlex- $\epsilon $ , an ESR foot prosthesis equipped with a light and manually adjustable mechanism that allows for varying its stiffness in the sagittal plane, and a systematic approach to calculate its rotation-stiffness curves are presented. Through a design of experiment conducted numerically using a two-dimensional (2D) finite element (FE) model, calibrated experimentally, a geometric parameter whose variation alters the sagittal plane stiffness of a prosthesis originally designed with invariable stiffness, MyFlex- $\delta $ , was determined. After building the mechanism and integrating it into MyFlex- $\delta $ to obtain MyFlex- $\epsilon $ , the displacement-force curves of the latter through tests equivalent to the static tests specified in ISO 10328 were determined. Based on the experimental results, the 2D FE model of MyFlex- $\epsilon $ was built and calibrated to determine its rotation-stiffness curves in the sagittal plane. Comparing the rotation-stiffness curves obtained with the most compliant setting to the stiffest setting, stiffness variations of 119%, 122%, 138%, and 162% at plantarflexion angles of −5° and −2.5°, and dorsiflexion angles of 7.5° and 15°, respectively, were found.