This paper focuses on the design and comparison of different deep neural networks for the real-time prediction of locomotor and transition intentions of one osseointegrated transfemoral amputee using only data from inertial measurement units. The deep neural networks are based on convolutional neural networks, recurrent neural networks, and convolutional recurrent neural networks. The architectures' input are features in both the time domain and the time-frequency domain, which are derived from either one inertial measurement unit (placed above the prosthetic knee) or two inertial measurement units (placed above and below the prosthetic knee). The prediction of eight different locomotion modes (i.e., sitting, standing, level ground walking, stair ascent and descent, ramp ascent and descent, walking on uneven terrain) and the twenty-four transitions among them is investigated. The study shows that a recurrent neural network, realized with four layers of gated recurrent unit networks, achieves (with a 5-fold cross-validation) a mean F1 score of 84.78% and 86.50% using one inertial measurement unit, and 93.06% and 89.99% using two inertial measurement units, with or without sitting, respectively.
This paper focuses on the classification of seven locomotion modes (sitting, standing, level ground walking, ramp ascent and descent, stair ascent and descent), the transitions among these modes, and the gait phases within each mode, by only using data in the frequency domain from one or two inertial measurement units. Different deep neural network configurations are investigated and compared by combining convolutional and recurrent layers. The results show that a system composed of a convolutional neural network followed by a long short-term memory network is able to classify with a mean -score of 0.89 and 0.91 for ten healthy subjects, and of 0.92 and 0.95 for one osseointegrated transfemoral amputee subject (excluding the gait phases because they are not labeled in the data-set), using one and two inertial measurement units, respectively, with a 5-fold cross-validation. The promising results obtained in this study pave the way for using deep learning for the control of transfemoral prostheses with a minimum number of inertial measurement units.
1 March 2021 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
This paper proposes to use deep reinforcement learning for the simulation of physics-based musculoskeletal models of both healthy subjects and transfemoral prostheses' users during normal level-ground walking. The deep reinforcement learning algorithm is based on the proximal policy optimization approach in combination with imitation learning to guarantee a natural walking gait while reducing the computational time of the training. Firstly, the optimization algorithm is implemented for the OpenSim model of a healthy subject and validated with experimental data from a public data-set. Afterwards, the optimization algorithm is implemented for the OpenSim model of a generic transfemoral prosthesis' user, which has been obtained by reducing the number of muscles around the knee and ankle joints and, specifically, by keeping only the uniarticular ones. The model of the transfemoral prosthesis' user shows a stable gait, with a forward dynamic comparable to the healthy subject's, yet using higher muscles' forces. Even though the computed muscles' forces could not be directly used as control inputs for muscle-like linear actuators due to their pattern, this study paves the way for using deep reinforcement learning for the design of the control architecture of transfemoral prostheses.
The paper focuses on the mechatronic design of a robotic manipulator that is meant to be mounted on an Unmanned Aerial Vehicle (UAV) and to be used in industrial applications, for both aerial inspection by contact and aerial manipulation. The combination of an UAV and the robotic manipulator realizes the aerial manipulator. The robotic manipulator is designed to be versatile so that the aerial manipulator can perform both trajectory tracking in free flight and physical interaction. Moreover, the robotic manipulator can be mounted on commercially available UAVs a modular way without interfering with the existing onboard control architecture. Experimental test are validating the overall mechatronic design.
The development of electronic skins and wearable devices is rapidly growing due to their broad application fields, such as for biomedical, health monitoring, or robotic purposes. In particular, tactile sensors based on piezoelectric polymers, which feature self-powering capability, have been widely used thanks to their flexibility and light weight. Among these, poly(vinylidenefluoride-trifluoroethylene) (PVDF-TrFE) presents enhanced piezoelectric properties, especially if manufactured in a nanofiber shape. In this work, the enhanced piezoelectric performances of PVDF-TrFE nanofibers were exploited to manufacture a flexible sensor which can be used for wearable applications or e-skin. The piezoelectric signal was collected by carbon black (CB)-based electrodes, which were added to the active layer in a sandwich-like structure. The sensor was electromechanically characterized in a frequency range between 0.25 Hz and 20 Hz—which is consistent with human activities (i.e., gait cycle or accidental bumps)—showing a sensitivity of up to 4 mV/N. The parameters of the signal acquisition circuit were tuned to enable the sensor to work at the required frequency. The proposed electrical model of the nanofibrous piezoelectric sensor was validated by the experimental results. The sensitivity of the sensor remained above 77.5% of its original value after 106 cycles of fatigue testing with a 1 kN compressive force.
The prosthetic feet that are most often prescribed to individuals with K3/K4 levels of ambulation are the ESR feet. ESR stands for energy-storing and -releasing. The elastic energy is stored by the elastic elements in composite materials (carbon fiber or glass fiber). ESR feet must be developed and optimized in terms of stiffness, taking into account the loads that a healthy human foot undergoes and its kinematics while walking. So far, state-of-the-art analyses show that the literature approaches for prosthetic foot design are not based on a systematic methodology. With the aim of optimizing the stiffness of ESR feet following a methodological procedure, a methodology based on finite element structural analysis, standard static testing (ISO 10328) and functional verification was optimized and it is presented in this paper. During the path of optimization of the foot prototypes, this methodology was validated experimentally. It includes the following: (i) geometry optimization through two-dimensional finite element analysis; (ii) material properties optimization through three-dimensional finite element analysis; (iii) validation test on physical prototypes; (iv) functionality verification through dynamic finite element analysis. The design and functional verification of MyFlex-, a three-blade ESR foot prosthesis, is presented to describe the methodology and demonstrate its usability.