Ga-Yeon Lee

Dr. Ga-Yeon Lee

Department of Materials Science and Engineering, Yonsei University, Seoul 03722, Korea

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 January 2018 in ACS Sensors
Verified
Journal Article
Closed access
GLGa-Yeon Lee
Ga-Yeon Lee
JPJun-Hee Park
Jun-Hee Park
YCYoung Wook Chang
Young Wook Chang
SCSungbo Cho
Sungbo Cho
MKMin-Jung Kang
Min-Jung Kang
JPJae-Cheol Pyun
Jae-Cheol Pyun

16 December 2019 in Sensors
Verified
Journal Article
Open access
PDF file
SCSomasekhar R. Chinnadayyala
Somasekhar R. Chinnadayyala
JPJinsoo Park
Jinsoo Park
YKYoung Hyo Kim
Young Hyo Kim
SCSeong Hye Choi
Seong Hye Choi
SLSang-Myung Lee
Sang-Myung Lee
Sungbo ChoSungbo Cho
Sungbo Cho
An electrochemical capacitance immunosensor based on an interdigitated wave-shaped micro electrode array (IDWµE) for direct and label-free detection of C-reactive protein (CRP) was reported. A self-assembled monolayer (SAM) of dithiobis (succinimidyl propionate) (DTSP) was used to modify the electrode array for antibody immobilization. The SAM functionalized electrode array was characterized morphologically by atomic force microscopy (AFM) and energy dispersive X-ray spectroscopy (EDX). The nature of gold-sulfur interactions on SAM-treated electrode array was probed by X-ray photoelectron spectroscopy (XPS). The covalent linking of anti-CRP-antibodies onto the SAM modified electrode array was characterized morphologically through AFM, and electrochemically through cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The application of phosphate-buffered saline (PBS) and human serum (HS) samples containing different concentrations of CRP in the electrode array caused changes in the electrode interfacial capacitance upon CRP binding. CRP concentrations in PBS and HS were determined quantitatively by measuring the change in capacitance (ΔC) through EIS. The electrode immobilized with anti-CRP-antibodies showed an increase in ΔC with the addition of CRP concentrations over a range of 0.01–10,000 ng mL−1. The electrode showed detection limits of 0.025 ng mL−1 and 0.23 ng mL−1 (S/N = 3) in PBS and HS, respectively. The biosensor showed a good reproducibility (relative standard deviation (RSD), 1.70%), repeatability (RSD, 1.95%), and adequate selectivity in presence of interferents towards CRP detection. The sensor also exhibited a significant storage stability of 2 weeks at 4 °C in 1× PBS.

1 November 2018 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
GLGa-Yeon Lee
Ga-Yeon Lee
JPJun-Hee Park
Jun-Hee Park
YCYoung Wook Chang
Young Wook Chang
MKMin-Jung Kang
Min-Jung Kang
Sungbo ChoSungbo Cho
Sungbo Cho
JPJae-Chul Pyun
Jae-Chul Pyun

22 April 2023 in Ceramics International
Verified
Journal Article
Closed access
RGRenu Gupta
Renu Gupta
EKEun Young Kim
Eun Young Kim
HSHyo-Soon Shin
Hyo-Soon Shin
GLGa-Yeon Lee
Ga-Yeon Lee
DYDong-Hun Yeo
Dong-Hun Yeo

5 December 2016 in Sensors
Verified
Journal Article
Open access
PDF file
IPIlhwan Park
Ilhwan Park
YHYeonhee Hong
Yeonhee Hong
YJYoung-Hoo Jun
Young-Hoo Jun
GLGa-Yeon Lee
Ga-Yeon Lee
HJHee-Sook Jun
Hee-Sook Jun
Sungbo ChoSungbo Cho
Sungbo Cho
Electrical cell-substrate impedance sensing is increasingly being used for label-free and real-time monitoring of changes in cell morphology and number during cell growth, drug screening, and differentiation. In this study, we evaluated the feasibility of using ECIS to monitor C2C12 myoblast differentiation using a fabricated indium tin oxide (ITO) electrode-based chip. C2C12 myoblast differentiation on the ITO electrode was validated based on decreases in the mRNA level of MyoD and increases in the mRNA levels of myogenin and myosin heavy chain (MHC). Additionally, MHC expression and morphological changes in myoblasts differentiated on the ITO electrode were comparable to those in cells in the control culture dish. From the monitoring the integration of the resistance change at 21.5 kHz, the cell differentiation was label-free and real-time detectable in 30 h of differentiation (p < 0.05).

12 November 2018 in Sensors
Verified
Journal Article
Open access
PDF file
BJBo Jin
Bo Jin
GLGa-Yeon Lee
Ga-Yeon Lee
CPChanOh Park
ChanOh Park
DKDonghoon Kim
Donghoon Kim
WCWonyeong Choi
Wonyeong Choi
Jeong-Soo LeeJeong-Soo Lee
Jeong-Soo Lee
We report the electrical characteristics and pH responses of a Si-nanonet ion-sensitive field-effect transistor with ultra-thin parylene-H as a gate sensing membrane. The fabricated device shows excellent DC characteristics: a low subthreshold swing of 85 mV/dec, a high current on/off ratio of ~107 and a low gate leakage current of ~10−10 A. The low interface trap density of 1.04 × 1012 cm−2 and high field-effect mobility of 510 cm2V−1s−1 were obtained. The pH responses of the devices were evaluated in various pH buffer solutions. A high pH sensitivity of 48.1 ± 0.5 mV/pH with a device-to-device variation of ~6.1% was achieved. From the low-frequency noise characterization, the signal-to-noise ratio was extracted as high as ~3400 A/A with the lowest noise equivalent pH value of ~0.002 pH. These excellent intrinsic electrical and pH sensing performances suggest that parylene-H can be promising as a sensing membrane in an ISFET-based biosensor platform.