Highly sensitive silicon-nanonet biologically active field-effect transistors (BioFETs) for the detection of influenza A (H1N1) virus have been demonstrated using a top-down process. The BioFETs show excellent intrinsic electrical characteristics, such as a low threshold voltage of 0.7 V and high on/off current ratio of ∼107. The sensing characteristics were measured at room temperature with various concentrations of H1N1 virus in a range of 10 pg/ml -100 ng/ml. The current-related sensitivity (SI) shows a higher value in the subthreshold regime, where SI is strongly correlated with the subthreshold swing (SS). The voltage-related sensitivity (SV) shows almost constant behavior from the subthreshold regime to the linear regime. The limit of detection (LOD) was 10 pg/ml, which is 6 times lower than values previously reported for FET-type sensors. In addition, the nanonet sensors exhibit high specificity to influenza A virus with negligible false positive for influenza B virus.
We experimentally demonstrate Si-based electrolyte-gated transistors (EGTs) for detecting urea. The top-down-fabricated device exhibited excellent intrinsic characteristics, including a low subthreshold swing (SS) (~80 mV/dec) and a high on/off current ratio (~107). The sensitivity, which varied depending on the operation regime, was analyzed with the urea concentrations ranging from 0.1 to 316 mM. The current-related response could be enhanced by reducing the SS of the devices, whereas the voltage-related response remained relatively constant. The urea sensitivity in the subthreshold regime was as high as 1.9 dec/pUrea, four times higher than the reported value. The extracted power consumption of 0.3 nW was extremely low compared to other FET-type sensors.
The highly sensitive detection of peanut allergens (PAs) using silicon-based electrolyte-gated transistors (Si-EGTs) was demonstrated. The Si-EGT was made using a top-down technique. The fabricated Si-EGT showed excellent intrinsic electrical characteristics, including a low threshold voltage of 0.7 V, low subthreshold swing of <70 mV/dec, and low gate leakage of <10 pA. Surface functionalization and immobilization of antibodies were performed for the selective detection of PAs. The voltage-related sensitivity (SV) showed a constant behavior from the subthreshold regime to the linear regime. The current-related sensitivity (SI) was high in the subthreshold regime and then significantly decreased as the drain current increased. The limit of detection (LOD) was calculated to be as low as 25 pg/mL based on SI characteristics, which is the lowest value reported to date in the literature for various sensor methodologies. The Si-EGT showed selective detection of PA through a non-specific control test. These results confirm that Si-EGT is a high-sensitivity and low-power biosensor for PA detection.
We report the electrical characteristics and pH responses of a Si-nanonet ion-sensitive field-effect transistor with ultra-thin parylene-H as a gate sensing membrane. The fabricated device shows excellent DC characteristics: a low subthreshold swing of 85 mV/dec, a high current on/off ratio of ~107 and a low gate leakage current of ~10−10 A. The low interface trap density of 1.04 × 1012 cm−2 and high field-effect mobility of 510 cm2V−1s−1 were obtained. The pH responses of the devices were evaluated in various pH buffer solutions. A high pH sensitivity of 48.1 ± 0.5 mV/pH with a device-to-device variation of ~6.1% was achieved. From the low-frequency noise characterization, the signal-to-noise ratio was extracted as high as ~3400 A/A with the lowest noise equivalent pH value of ~0.002 pH. These excellent intrinsic electrical and pH sensing performances suggest that parylene-H can be promising as a sensing membrane in an ISFET-based biosensor platform.
The sensing responses of SARS-CoV-2 spike protein using top-down-fabricated Si-based electrolyte-gated transistors (EGTs) have been investigated. An aptamer was employed as a receptor for the SARS-CoV-2 spike protein. The EGT demonstrated excellent intrinsic characteristics and higher sensitivity in the subthreshold regime compared to the linear regime. The limit of detection (LOD) was achieved as low as 0.94 pg/mL and 20 pg/mL for the current and voltage sensitivity, respectively. To analyze the sensing responses of EGT in detecting the aptamer–SARS-CoV-2 spike protein conjugate, a lumped-capacitive model with the presence of an effective dipole potential and an effective capacitance of the functionalized layer component was employed. The aptamer-functionalized EGT showed high sensitivity even in 10 mM phosphate-buffered saline (PBS) solution. These results suggest that Si-based EGTs are a highly promising method for detecting SARS-CoV-2 spike proteins.
Carbon nanoneedles (CNNs) were grown using a plasma-enhanced chemical vapor deposition process in which the source gas (C2H2) was turned off 10 min before the NH3 flow and plasma were turned off. It is demonstrated that tubular carbon nanofibers (CNFs) grow while the source gas is on. However, once the source gas is turned off, the Ni catalyst at the top of each CNF splits to form a small catalyst that remains at the top of the tube and a larger catalyst that travels down the interior of the tube. We postulate that the motion of the bottom (larger) catalyst is driven by etching of the graphitic walls and ‘cups’ inside the CNF. This process, combined with slowing growth of the CNFs and etching of the material above the bottom catalyst, converts the carbon nanofibers to the final nanoneedle shape.