Augmented reality (AR)-based surgical navigation may offer new possibilities for safe and accurate surgical execution of complex osteotomies. In this study we investigated the feasibility of navigating the periacetabular osteotomy of Ganz (PAO), known as one of the most complex orthopedic interventions, on two cadaveric pelves under realistic operating room conditions. Preoperative planning was conducted on computed tomography (CT)-reconstructed 3D models using an in-house developed software, which allowed creating cutting plane objects for planning of the osteotomies and reorientation of the acetabular fragment. An AR application was developed comprising point-based registration, motion compensation and guidance for osteotomies as well as fragment reorientation. Navigation accuracy was evaluated on CT-reconstructed 3D models, resulting in an error of 10.8 mm for osteotomy starting points and 5.4° for osteotomy directions. The reorientation errors were 6.7°, 7.0° and 0.9° for the x-, y- and z-axis, respectively. Average postoperative error of LCE angle was 4.5°. Our study demonstrated that the AR-based execution of complex osteotomies is feasible. Fragment realignment navigation needs further improvement, although it is more accurate than the state of the art in PAO surgery.
Background: Legg–Calvé–Perthes (LCP) is a common orthopedic childhood disease that causes a deformity of the femoral head and to an adaptive deformity of the acetabulum. The altered joint biomechanics can result in early joint degeneration that requires total hip arthroplasty. In 2002, Ganz et al. introduced the femoral head reduction osteotomy (FHRO) as a direct joint-preserving treatment. The procedure remains one of the most challenging in hip surgery. Computer-based 3D preoperative planning and patient-specific navigation instruments have been successfully used to reduce technical complexity in other anatomies. The purpose of this study was to report the first results in the treatment of 6 patients to investigate whether our approach is feasible and safe.Methods: In this retrospective pilot study, 6 LCP patients were treated with FHRO in multiple centers between May 2017 and June 2019. Based on patient-specific 3D-models of the hips, the surgeries were simulated in a step-wise fashion. Patient-specific instruments tailored for FHRO were designed, 3D-printed and used in the surgeries for navigating the osteotomies. The results were assessed radiographically [diameter index, sphericity index, Stulberg classification, extrusion index, LCE-, Tönnis-, CCD-angle and Shenton line] and the time and costs were recorded. Radiologic values were tested for normal distribution using the Shapiro–Wilk test and for significance using Wilcoxon signed-rank test.Results: The sphericity index improved postoperatively by 20% (p = 0.028). The postoperative diameter of the femoral head differed by only 1.8% (p = 0.043) from the contralateral side and Stulberg grading improved from poor coxarthrosis outcome to good outcome (p = 0.026). All patients underwent acetabular reorientation by periacetabular osteotomy. The average time (in minutes) for preliminary analysis, computer simulation and patient-specific instrument design was 63 (±48), 156 (±64) and 105 (±68.5), respectively.Conclusion: The clinical feasibility of our approach to FHRO has been demonstrated. The results showed significant improvement compared to the preoperative situation. All operations were performed by experienced surgeons; nevertheless, three complications occurred, showing that FHRO remains one of the most complex hip surgeries even with computer assistance. However, none of the complications were directly related to the simulation or the navigation technique.
Minimally invasive surgical procedures have a flat learning curve, especially in the initial period of a surgeon's training. Pelvitrainers enable the prospective surgeon to drill the surgical technique, including camera navigation, instrument manipulation, and the individual steps of the operation, on a model rather than a patient. Integrating the pelvitrainer into standardized surgical training programs is challenging, but would be essential to achieve optimum effects of long duration in surgical education. The pelvitrainer Realsimulator 2.0 (Endodevelop) was evaluated in 16 standardized training courses (at three training centers) of the German Working Group for Gynecological Endoscopy (AGE e.V.) from 2017 to 2020, The training concept was implemented and evaluated in a prospective, multicenter, interdisciplinary, multinational setting. One hundred and eighty of 206 physicians (response rate 87.4%) completed the multi-stage training concept successfully. A significant (p < 0.001) objective improvement (positive learning curve) was observed for all exercises on the pelvitrainer. The trainer's subjective evaluation revealed positive ratings for design (median 82%, IQR 71-91%), camera navigation (87%, IQR 76-95%), and instrument manipulation (median 87%, IQR 77-94%). A follow-up survey performed six months after the course confirmed its sustainable and high benefits in clinical routine (median 82%, IQR 70-97%). The present investigation proved the high educational value of pelvitrainers, which can be enhanced by using a structured training concept. The benefit of training courses for health care justifies their incorporation into a standardized training curriculum. The completion of such training courses should be regarded as a prerequisite for a doctor to qualify as an independent surgeon.
13 December 2022 in Minimally Invasive Therapy & Allied Technologies
Endometrial cancer is the most common carcinoma of the female genital organs and cervical cancer is the leading cause of cancer death in women worldwide. The aim of this review is to evaluate the role of laparoscopic hysterectomy in patients with endometrial and cervical cancer in this period, and analyze the outcome of hysterectomy in terms of survival. Moreover, we present the historical background, new techniques, the anatomical features, and surgical steps of radical hysterectomy. According to new evidence, minimally invasive surgery in patients with cervical cancer is associated with higher rates of recurrence and mortality compared to the open approach. Despite the numerous explanations offered for this phenomenon, the reasons for these results are unclear. Additional large trials have been launched to reevaluate the above-mentioned data. On contrary, the laparoscopic approach provides surgical outcomes and similar survival rates as open surgery in patients with early endometrial carcinoma. Furthermore, the radicality of hysterectomy does not influence local recurrence rates or overall survival in cases with complete surgical removal of the tumor. A laparoscopic radical hysterectomy is no longer an option in patients with cervical cancer. When minimally invasive surgery is offered, the patients must be counseled in detail about the current debate.
In clinical practice, image-based postoperative evaluation is still performed without state-of-the-art computer methods, as these are not sufficiently automated. In this study we propose a fully automatic 3D postoperative outcome quantification method for the relevant steps of orthopaedic interventions on the example of Periacetabular Osteotomy of Ganz (PAO). A typical orthopaedic intervention involves cutting bone, anatomy manipulation and repositioning as well as implant placement. Our method includes a segmentation based deep learning approach for detection and quantification of the cuts. Furthermore, anatomy repositioning was quantified through a multi-step registration method, which entailed a coarse alignment of the pre- and postoperative CT images followed by a fine fragment alignment of the repositioned anatomy. Implant (i.e., screw) position was identified by 3D Hough transform for line detection combined with fast voxel traversal based on ray tracing. The feasibility of our approach was investigated on 27 interventions and compared against manually performed 3D outcome evaluations. The results show that our method can accurately assess the quality and accuracy of the surgery. Our evaluation of the fragment repositioning showed a cumulative error for the coarse and fine alignment of 2.1 mm. Our evaluation of screw placement accuracy resulted in a distance error of 1.32 mm for screw head location and an angular deviation of 1.1° for screw axis. As a next step we will explore generalisation capabilities by applying the method to different interventions.