Anna Theresa Stüber

Ms. Anna Theresa Stüber

Researcher
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 July 2023 in Investigative Radiology
Verified
Journal Article
Open access
ASAnna Theresa Stüber
Anna Theresa Stüber
SCStefan Msc Coors
Stefan Msc Coors
BSBalthasar Schachtner
Balthasar Schachtner
TWTobias Msc Weber
Tobias Msc Weber
DRDavid Rügamer
David Rügamer
MIMichael Ingrisch
Michael Ingrisch
Objectives: Optimizing a machine learning (ML) pipeline for radiomics analysis involves numerous choices in data set composition, preprocessing, and model selection. Objective identification of the optimal setup is complicated by correlated features, interdependency structures, and a multitude of available ML algorithms. Therefore, we present a radiomics-based benchmarking framework to optimize a comprehensive ML pipeline for the prediction of overall survival. This study is conducted on an image set of patients with hepatic metastases of colorectal cancer, for which radiomics features of the whole liver and of metastases from computed tomography images were calculated. A mixed model approach was used to find the optimal pipeline configuration and to identify the added prognostic value of radiomics features. Materials and Methods: In this study, a large-scale ML benchmark pipeline consisting of preprocessing, feature selection, dimensionality reduction, hyperparameter optimization, and training of different models was developed for radiomics-based survival analysis. Portal-venous computed tomography imaging data from a previous prospective randomized trial evaluating radioembolization of liver metastases of colorectal cancer were quantitatively accessible through a radiomics approach. One thousand two hundred eighteen radiomics features of hepatic metastases and the whole liver were calculated, and 19 clinical parameters (age, sex, laboratory values, and treatment) were available for each patient. Three ML algorithms—a regression model with elastic net regularization (glmnet), a random survival forest (RSF), and a gradient tree-boosting technique (xgboost)—were evaluated for 5 combinations of clinical data, tumor radiomics, and whole-liver features. Hyperparameter optimization and model evaluation were optimized toward the performance metric integrated Brier score via nested cross-validation. To address dependency structures in the benchmark setup, a mixed-model approach was developed to compare ML and data configurations and to identify the best-performing model. Results: Within our radiomics-based benchmark experiment, 60 ML pipeline variations were evaluated on clinical data and radiomics features from 491 patients. Descriptive analysis of the benchmark results showed a preference for RSF-based pipelines, especially for the combination of clinical data with radiomics features. This observation was supported by the quantitative analysis via a linear mixed model approach, computed to differentiate the effect of data sets and pipeline configurations on the resulting performance. This revealed the RSF pipelines to consistently perform similar or better than glmnet and xgboost. Further, for the RSF, there was no significantly better-performing pipeline composition regarding the sort of preprocessing or hyperparameter optimization. Conclusions: Our study introduces a benchmark framework for radiomics-based survival analysis, aimed at identifying the optimal settings with respect to different radiomics data sources and various ML pipeline variations, including preprocessing techniques and learning algorithms. A suitable analysis tool for the benchmark results is provided via a mixed model approach, which showed for our study on patients with intrahepatic liver metastases, that radiomics features captured the patients' clinical situation in a manner comparable to the provided information solely from clinical parameters. However, we did not observe a relevant additional prognostic value obtained by these radiomics features.

5 August 2024 in Radiotherapy and Oncology
Verified
Journal Article
Open access
RKRabea Klaar
Rabea Klaar
MRMoritz Rabe
Moritz Rabe
ASAnna Theresa Stüber
Anna Theresa Stüber
SHSvenja Hering
Svenja Hering
SCStefanie Corradini
Stefanie Corradini
CKChristopher Kurz
Christopher Kurz
Background and purpose: Radiation-induced pneumonitis (RP), diagnosed 6-12 weeks after treatment, is a complication of lung tumor radiotherapy. So far, clinical and dosimetric parameters have not been reliable in predicting RP. We propose using non-contrast enhanced magnetic resonance imaging (MRI) based functional parameters acquired over the treatment course for patient stratification for improved follow-up. Materials and methods: 23 lung tumor patients received MR-guided hypofractionated stereotactic body radiation therapy at a 0.35 T MR-Linac. Ventilation- and perfusion-maps were generated from 2D-cine MRIscans acquired after the first and last treatment fraction (Fx) using non-uniform Fourier decomposition. The relative differences in ventilation and perfusion between last and first Fx in three regions (planning target volume (PTV), lung volume receiving more than 20 Gy (V20) excluding PTV, whole tumor-bearing lung excluding PTV) and three dosimetric parameters (mean lung dose, V20, mean dose to the gross tumor volume) were investigated. Univariate receiver operating characteristic curve- area under the curve (ROC- AUC) analysis was performed (endpoint RP grade >= 1) using 5000 bootstrapping samples. Differences between RP and non-RP patients were tested for statistical significance with the non-parametric Mann-Whitney U test (alpha = 0.05). Results: 14/23 patients developed RP of grade >= 1 within 3 months. The dosimetric parameters showed no significant differences between RP and non-RP patients. In contrast, the functional parameters, especially the relative ventilation difference in the PTV, achieved a p-value <0.05 and an AUC value of 0.84. Conclusion: MRI-based functional parameters extracted from 2D-cine MRI-scans were found to be predictive of RP development in lung tumor patients.

2 February 2023 in International journal of legal medicine
Verified
Journal Article
Open access
PDF file
PWPhilipp Wesp
Philipp Wesp
BSBastian Sabel
Bastian Sabel
AMAndreas Mittermeier
Andreas Mittermeier
ASAnna Theresa Stüber
Anna Theresa Stüber
KJKatharina Jeblick
Katharina Jeblick
BSBalthasar Maria Schachtner
Balthasar Maria Schachtner
Background: Deep learning is a promising technique to improve radiological age assessment. However, expensive manual annotation by experts poses a bottleneck for creating large datasets to appropriately train deep neural networks. We propose an object detection approach to automatically annotate the medial clavicular epiphyseal cartilages in computed tomography (CT) scans. Methods: The sternoclavicular joints were selected as structure-of-interest (SOI) in chest CT scans and served as an easy-to-identify proxy for the actual medial clavicular epiphyseal cartilages. CT slices containing the SOI were manually annotated with bounding boxes around the SOI. All slices in the training set were used to train the object detection network RetinaNet. Afterwards, the network was applied individually to all slices of the test scans for SOI detection. Bounding box and slice position of the detection with the highest classification score were used as the location estimate for the medial clavicular epiphyseal cartilages inside the CT scan. Results: From 100 CT scans of 82 patients, 29,656 slices were used for training and 30,846 slices from 110 CT scans of 110 different patients for testing the object detection network. The location estimate from the deep learning approach for the SOI was in a correct slice in 97/110 (88%), misplaced by one slice in 5/110 (5%), and missing in 8/110 (7%) test scans. No estimate was misplaced by more than one slice. Conclusions: We demonstrated a robust automated approach for annotating the medial clavicular epiphyseal cartilages. This enables training and testing of deep neural networks for age assessment.

28 December 2020 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
JRJohannes Rueckel
Johannes Rueckel
NFNicola Fink
Nicola Fink
SKSophia Kaestle
Sophia Kaestle
ASAnna Theresa Stüber
Anna Theresa Stüber
VSVincent Schwarze
Vincent Schwarze
BSBastian Sabel
Bastian Sabel
(1) Background: Time-consuming SARS-CoV-2 RT-PCR suffers from limited sensitivity in early infection stages whereas fast available chest CT can already raise COVID-19 suspicion. Nevertheless, radiologists’ performance to differentiate COVID-19, especially from influenza pneumonia, is not sufficiently characterized. (2) Methods: A total of 201 pneumonia CTs were identified and divided into subgroups based on RT-PCR: 78 COVID-19 CTs, 65 influenza CTs and 62 Non-COVID-19-Non-influenza (NCNI) CTs. Three radiology experts (blinded from RT-PCR results) raised pathogen-specific suspicion (separately for COVID-19, influenza, bacterial pneumonia and fungal pneumonia) according to the following reading scores: 0—not typical/1—possible/2—highly suspected. Diagnostic performances were calculated with RT-PCR as a reference standard. Dependencies of radiologists’ pathogen suspicion scores were characterized by Pearson’s Chi2 Test for Independence. (3) Results: Depending on whether the intermediate reading score 1 was considered as positive or negative, radiologists correctly classified 83–85% (vs. NCNI)/79–82% (vs. influenza) of COVID-19 cases (sensitivity up to 94%). Contrarily, radiologists correctly classified only 52–56% (vs. NCNI)/50–60% (vs. COVID-19) of influenza cases. The COVID-19 scoring was more specific than the influenza scoring compared with suspected bacterial or fungal infection. (4) Conclusions: High-accuracy COVID-19 detection by CT might expedite patient management even during the upcoming influenza season.

3 September 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
RSRobert Stahl
Robert Stahl
ASAnna Theresa Stüber
Anna Theresa Stüber
RWRebecca Wania
Rebecca Wania
MIMichael Ingrisch
Michael Ingrisch
MAMaryam Ostadi Ataabadi
Maryam Ostadi Ataabadi
VPVera Pedersen
Vera Pedersen
Background/Objectives: Traumatic intracranial hemorrhage (tICH) in older adults following low-energy falls (LEF) represents a common yet diagnostically challenging condition in the emergency department (ED), where predicting injury prior to computed tomography (CT) remains difficult. Machine learning (ML) has been proposed to support CT decision-making, but its feasibility using routinely available pre-CT clinical variables in this specific population remains unclear. This study presents a systematic exploratory benchmarking of ML pipeline configurations for pre-CT tICH prediction in a well-defined retrospective cohort of older emergency patients following LEF. Methods: We performed a secondary analysis from a retrospective observational bicentric study from two university hospital EDs, including 2250 patients aged ≥65 years presenting after an LEF and undergoing cranial CT. Clinical data were extracted manually from electronic health records (EHRs). Eighteen pre-CT clinical features retrieved from electronic health records were selected based on routine availability and ≤10% missingness. Overall, 1224 valid ML pipeline configurations, combining nine classification algorithms, six imputation strategies, four class-balancing approaches, and optional hyperparameter tuning, were evaluated using 10-fold stratified cross-validation on a training set. The 20 highest-ranked configurations by cross-validation AUC were then assessed on a previously inspected exploratory hold-out test set (n = 563); training-derived rule-out operating points were evaluable for 17 of these 20, as three tuned SVM configurations lacked stored out-of-fold predictions. Results: tICH prevalence was 7.0% (n = 158). Across the 20 highest-ranked configurations, hold-out AUC ranged from 0.517 to 0.585, with Matthews correlation coefficient near zero and balanced accuracy of approximately 50% throughout, indicating differences in operating point rather than in discriminative ability. Some of these top-ranked pipelines reached higher cross-validation AUC (up to 0.679) but detected no cases at the default 0.5 threshold—an effect of the decision threshold under class imbalance rather than of the models’ rank-order discrimination, which was itself limited (hold-out AUC of 0.517–0.585). Conclusions: Despite comprehensive exploratory benchmarking across 1224 ML pipelines, routinely available pre-CT clinical features did not provide sufficient discriminatory signal to develop a clinically useful tICH prediction model in this cohort of CT-imaged older adults following LEF. These findings indicate that none of the evaluated configurations produced clinically adequate performance; this near-chance result persisted across all pipelines and most plausibly reflects a combination of limited feature signal, low outcome prevalence, and a sample size below the level required for reliable model development at this event rate. Future studies should target substantially larger prospective multicenter cohorts and evaluate additional feature domains, including structured clinical examination findings, point-of-care biomarkers, and imaging features.