Nicholas Andreas Beckmann

Prof. Dr. Nicholas Andreas Beckmann

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2018 in Bone & Joint Research
Verified
Journal Article
Open access
NBNicholas Andreas Beckmann
Nicholas Andreas Beckmann
RBR. G. Bitsch
R. G. Bitsch
MGM. Gondan
M. Gondan
MSM. Schonhoff
M. Schonhoff
SJS. Jaeger
S. Jaeger
Objectives: In order to address acetabular defects, porous metal revision acetabular components and augments have been developed, which require fixation to each other. The fixation technique that results in the smallest relative movement between the components, as well as its influence on the primary stability with the host bone, have not previously been determined.Methods: A total of 18 composite hemipelvises with a Paprosky IIB defect were implanted using a porous titanium 56 mm multihole acetabular component and 1 cm augment. Each acetabular component and augment was affixed to the bone using two screws, while the method of fixation between the acetabular component and augment varied for the three groups of six hemipelvises: group S, screw fixation only; group SC, screw plus cement fixation; group C, cement fixation only. The implanted hemipelvises were cyclically loaded to three different loading maxima (0.5 kN, 0.9 kN, and 1.8 kN).Results: Screw fixation alone resulted in up to three times more movement (p = 0.006), especially when load was increased to 100% (p < 0.001), than with the other two fixation methods (C and SC). No significant difference was noted when a screw was added to the cement fixation. Increased load resulted in increased relative movement between the interfaces in all fixation methods (p < 0.001).Conclusion: Cement fixation between a porous titanium acetabular component and augment is associated with less relative movement than screw fixation alone for all implant interfaces, particularly with increasing loads. Adding a screw to the cement fixation did not offer any significant advantage. These results also show that the stability of the tested acetabular component/augment interface affects the stability of the construct that is affixed to the bone. Cite this article: N. A. Beckmann, R. G. Bitsch, M. Gondan, M. Schonhoff, S. Jaeger. Comparison of the stability of three fixation techniques between porous metal acetabular components and augments. Bone Joint Res 2018;7:282–288. DOI: 10.1302/2046-3758.74.BJR-2017-0198.R1.

12 September 2015 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
NBNicholas Andreas Beckmann
Nicholas Andreas Beckmann
TGTobias Gotterbarm
Tobias Gotterbarm
MIMoritz M Innmann
Moritz M Innmann
CMChristian Merle
Christian Merle
TBThomas Bruckner
Thomas Bruckner
MSMarcus R. Streit
Marcus R. Streit
The optimal type of bearing for hip arthroplasty remains a matter of debate. Ceramic-on-polyethylene (CoP) bearings are frequently used in younger and more active patients to reduce wear and increase biocompatibility compared to Metal-on-Polyethylene (MoP) bearings. However, in comparison to metal heads, the fracture risk of ceramic heads is higher. In addition, ceramic head fractures pose a serious complication which often necessitates major revision surgery. To date, there are no long-term data (>20 years of follow-up) reporting fracture rates of the ceramic femoral heads in CoP bearings. The purpose of this research was to investigate long-term CoP fracture rate. We evaluated the clinical and radiographic results of 348 cementless THAs treated with 2nd generation Biolox® Al2O3 Ceramic-on-Polyethylene (CoP) bearings consecutively implanted between January 1985 and December 1989. The mean age at implantation was 57 years. The patients were followed for a minimum of 20 years. At the final 111 had died, and 5 were lost to follow-up. The cumulative incidence of ceramic head fractures in the long-term was estimated using a competing risk analysis. The cumulative incidence of ceramic head fracture after 22-years was estimated with a competing risk analysis at 0.29 % after 22-years (SE = 2.09 %; 95 % - CI: 0.03-1.5 %). The radiographic analysis revealed no impending failures at final follow-up. The fracture rate of second-generation ceramic heads using a CoP articulation remains very low into the third decade after cementless THA.

Verified
Journal Article
Open access
PDF file
STStefanos Tsitlakidis
Stefanos Tsitlakidis
NBNicholas Andreas Beckmann
Nicholas Andreas Beckmann
SWSebastian Wolf
Sebastian Wolf
SHSebastien Hagmann
Sebastien Hagmann
TRTobias Renkawitz
Tobias Renkawitz
MGMarco Götze
Marco Götze
A variety of gait pathologies is seen in cerebral palsy. Movement patterns between different levels of functional impairment may differ. The objective of this work was the evaluation of Gross Motor Function Classification System (GMFCS) level-specific movement disorders. A total of 89 individuals with unilateral cerebral palsy and no history of prior treatment were included and classified according to their functional impairment. GMFCS level-specific differences, kinematics and joint moments, exclusively of the involved side, were analyzed for all planes for all lower limb joints, including pelvic and trunk movements. GMFCS level I and level II individuals most relevantly showed equinus/reduced dorsiflexion moments, knee flexion/reduced knee extension moments, reduced hip extension moments with pronounced flexion, internal hip rotation and reduced hip abduction. Anterior pelvic tilt, obliquity and retraction were found. Individuals with GMFCS level II were characterized by an additional pronounced reduction in all extensor moments, pronounced rotational malalignment and reduced hip abduction. The most striking characteristics of GMFCS level II were excessive anterior pelvic/trunk tilt and excessive trunk obliquity. Pronounced reduction in extensor moments and excessive trunk lean are distinguishing features of GMFCS level II. These patients would benefit particularly from surgical treatment restoring pelvic symmetry and improving hip abductor leverage. Future studies exploring GMFCS level-specific compensation of the sound limb and GMFCS level-specific malalignment are of interest.

13 November 2014 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
MKMatthias Cm Klotz
Matthias Cm Klotz
NBNicholas Andreas Beckmann
Nicholas Andreas Beckmann
RBRudi G Bitsch
Rudi G Bitsch
ESElisabeth Seebach
Elisabeth Seebach
TRTobias Reiner
Tobias Reiner
SJSebastian Jaeger
Sebastian Jaeger
In cases of poor bone quality, intraoperative torque measurement might be an alternative to preoperative dual-energy X-ray absorptiometry (DXA) to assess bone quality in total hip arthroplasty (THA). Trabecular peak torque measurement was applied in 14 paired fresh frozen human femurs. Here, a 6.5 × 23 mm wingblade was inserted into the proximal femur without harming the lateral cortical bone. Further tests of the proximal femur also evaluated bone strength (DXA, micro-computed tomography (μCT), monoaxial compression test), and the results were compared to the trabecular torque measurement. Student's t-test was used to compare the values of the groups. Pearson product–moment was applied to correlate the values of the peak torque measurement with the bone strength measured by DXA, μCT, and monoaxial compression test. In the femoral head, the mean trabecular peak torque was 4.38 ± 1.86 Nm. These values showed a strong correlation with the values of the DXA, the μCT, and the biomechanical load test (Pearson′s product–moment: DXA: 0.86, μCT-BMD: 0.80, load test: 0.85). Furthermore, the torque measurement showed a more pronounced correlation with the biomechanical load test compared to the DXA. The use of this method provides highly diagnostic information about bone quality. Since the approach was adjusted for THA, no harm of the lateral bone stock will result from this measurement during surgery. The results of this initial study employing small sample sizes indicate that this new method is as sensitive as DXA in predicting bone quality and may function as an intraoperative alternative to DXA in THA. Nevertheless, before this method will turn into clinical use, more research and clinical trials are necessary.

26 April 2016 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
TMTobias Peter Merkle
Tobias Peter Merkle
NBNicholas Andreas Beckmann
Nicholas Andreas Beckmann
TBTom Bruckner
Tom Bruckner
FZFelix Zeifang
Felix Zeifang
Arthroplasty is a proven treatment option for glenohumeral osteoarthritis. Common indications include primary or posttraumatic osteoarthritis, avascular necrosis of the humeral head, rotator cuff tear arthropathy and rheumatoid osteoarthritis. Arthroplasty is rarely performed among patients with glenohumeral dysmelia. An overuse of the upper limb in patients with thalidomide-induced phocomelia and people with similar congenital deformities like dysmelia results in premature wear of the shoulder joint. This study aims to evaluate our experience with cases of glenohumeral osteoarthritis caused by dysmelia and treated with arthroplasty. To date, few reports on the outcome of shoulder arthroplasty exist on this particular patient group. We included four dysmelic patients (five shoulders) with substantial glenoid dysplasia in a prospective database after approval by the local ethics committee. Once conservative treatment options had been exhausted, the patients were treated with shoulder arthroplasty and assessed clinically and radiographically before and after surgery. The mean patient age at the time of surgery was 50.4 years. The minimum follow-up time was 24 months (24–91 months). All patients experienced a considerable improvement of range of motion (ROM) and a relief of pain. No intra- or postoperative complications appeared. Patients with dysmelia have acceptable short and mid-term results with resurfacing hemiarthroplasty. It is an effective although somewhat complicated method to relieve pain and improve movement. Long-term performance of arthroplasty in patients with dysmelia remains to be seen, particularly with regard to the remaining problem of the altered and often deficient glenoid.

7 July 2022 in Children
Verified
Journal Article
Open access
PDF file
KGKatharina Susanne Gather
Katharina Susanne Gather
IMIvan Mavrev
Ivan Mavrev
SGSimone Gantz
Simone Gantz
TDThomas Dreher
Thomas Dreher
SHSebastien Hagmann
Sebastien Hagmann
NBNicholas Andreas Beckmann
Nicholas Andreas Beckmann
Closed reduction followed by spica casting is a conservative treatment for developmental dysplasia of the hip (DDH). Magnetic resonance imaging (MRI) can verify proper closed reduction of the dysplastic hip. Our aim was to find prognostic factors in the first MRI to predict the possible outcome of the initial treatment success by means of ultrasound monitoring according to Graf and the further development of the hip dysplasia or risk of recurrence in the radiological follow-up examinations. A total of 48 patients (96 hips) with DDH on at least one side, and who were treated with closed reduction and spica cast were included in this retrospective cohort study. Treatment began at a mean age of 9.9 weeks. The children were followed for 47.4 months on average. We performed closed reduction and spica casting under general balanced anaesthesia. This was directly followed by MRI to control the position/reduction of the femoral head without anaesthesia. The following parameters were measured in the MRI: hip abduction angle, coronal, anterior and posterior bony axial acetabular angles and pelvic width. A Graf alpha angle of at least 60° was considered successful. In the radiological follow-up controls, we evaluated for residual dysplasia or recurrence. In our cohort, we only found the abduction angle to be an influencing factor for improvement of the DDH. No other prognostic factors in MRI measurements, such as gender, age at time of the first spica cast, or treatment involving overhead extension were found to be predictive of mid-term outcomes. This may, however, be due to the relatively small number of treatment failures.