Sabine Sartoretti

Dr. Sabine Sartoretti


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 April 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ESElisabeth Sartoretti
Elisabeth Sartoretti
TSThomas Sartoretti
Thomas Sartoretti
CBChristoph Binkert
Christoph Binkert
ANArash Najafi
Arash Najafi
ÁSÁrpád Schwenk
Árpád Schwenk
SSSabine Sartoretti
Sabine Sartoretti
Acceleration of MR sequences beyond current parallel imaging techniques is possible with the Compressed SENSE technique that has recently become available for 1.5 and 3 Tesla scanners, for nearly all image contrasts and for 2D and 3D sequences. The impact of this technique on examination timing parameters and MR protocols in a clinical setting was investigated in this retrospective study. A numerical analysis of the examination timing parameters (scan time, exam time, procedure time, interscan delay time, changeover time, nonscan time) based on the MR protocols of 6 different body regions (brain, knee, lumbar spine, breast, shoulder) using MR log files was performed and the total number of examinations acquired from January to April both in 2017 and 2018 on a 1.5 T MR scanner was registered. Percentages, box plots and unpaired two-sided t tests were obtained for statistical evaluation. All examination timing parameters of the six anatomical regions analysed were significantly shortened after implementation of Compressed SENSE. On average, scan times were accelerated by 20.2% (p<0.0001) while procedure times were shortened by 16% (p<0.0001). Considering all anatomical regions and all MR protocols, 27% more examinations were performed over the same 4 month period in 2018 compared to 2017. Compressed SENSE allows for a significant acceleration of MR examinations and a considerable increase in the total number of MR examinations is possible.

8 November 2018 in Insights into Imaging
Verified
Journal Article
Open access
PDF file
TSThomas Sartoretti
Thomas Sartoretti
CRCarolin Reischauer
Carolin Reischauer
ESElisabeth Sartoretti
Elisabeth Sartoretti
CBChristoph Binkert
Christoph Binkert
ANArash Najafi
Arash Najafi
SSSabine Sartoretti
Sabine Sartoretti
Various techniques have been proposed which aim at scan time reduction and/or at improved image quality by increasing the spatial resolution. Compressed sensing (CS) takes advantage of the fact that MR images are usually sparse in some transform domains and recovers this sparse representation from undersampled data. CS may be combined with parallel imaging such as sensitivity encoding (SENSE), hereafter referred to as Compressed SENSE, to further accelerate image acquisition since both techniques rely on different ancillary information. In practice, Compressed SENSE may reduce scan times of two-dimensional (2D) and three-dimensional (3D) scans by up to 50% depending on the sequence acquired and it works on 1.5-T or 3-T scanners. Compressed SENSE may be applied to 2D and 3D sequences in various anatomies and image contrasts. Image artefacts (i.e. motion, metal and flow artefacts, susceptibility artefacts) frequently appear on magnetic resonance images. The Compressed SENSE technique may cause special artefacts, which might influence image assessment if they go undetected by imaging readers. Our institution has been using Compressed SENSE for over half a year, both in a neuroradiological setting and for musculoskeletal examinations. So far, three special image artefacts—called the wax-layer artefact, the streaky-linear artefact and the starry-sky artefact—have been encountered and we aim to review these main artefacts appearing in sequences acquired with Compressed SENSE. • Compressed SENSE combines compressed sensing and SENSE technique. • Compressed SENSE permits scan time reduction and increases spatial image resolution. • Images acquired with Compressed SENSE may present with special artefacts. • Knowledge of artefacts is necessary for reliable image assessment.

7 June 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
ESElisabeth Sartoretti
Elisabeth Sartoretti
MWMichael Wyss
Michael Wyss
AAAlex Alfieri
Alex Alfieri
CBChristoph A. Binkert
Christoph A. Binkert
CECyril Erne
Cyril Erne
TSThomas Sartoretti
Thomas Sartoretti
In this paper we sought to develop and assess the reproducibility of an updated 6-point grading system for lumbar foraminal stenosis based on the widely used Lee classification that more accurately describes lumbar foraminal stenosis as seen on high-resolution MRI. Grade A indicates absence of foraminal stenosis. Grades B, C, D and E indicate presence of foraminal stenosis with contact of the nerve root with surrounding anatomical structures (on one, two, three or four sides for B, C, D and E respectively) yet without morphological change of the nerve root. To each grade, a number code indicating the location of contact between the nerve root and surrounding anatomical structure(s) is appended. 1, 2, 3 and 4 indicate contact of the nerve root at superior, posterior, inferior and anterior position of the borders of the lumbar foramen. Grade F indicates presence of foraminal stenosis with morphological change of the nerve root. Three readers graded the lumbar foramina of 101 consecutive patients using high-resolution T2w (and T1w) MR images with a spatial resolution of beyond 0.5 mm3. Interreader agreement was excellent (Cohen’s Kappa = 0.866–1). Importantly, 30.6%/31.6%/32.2% (reader 1/reader 2/ reader 3) of foramina were assigned grades that did not appear in the original Lee grading system (grades B and D). The readers found no foramen that could not be described accurately with the updated grading system. Thus, an updated 6-point grading system for lumbar foraminal stenosis is reproducible and comprehensively describes lumbar foraminal stenosis as seen on high-resolution MRI.
1

29 June 2017 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
TSThomas Sartoretti
Thomas Sartoretti
ESE. Sartoretti
E. Sartoretti
SRS. Rauch
S. Rauch
CBC. Binkert
C. Binkert
MWM. Wyss
M. Wyss
SSSabine Sartoretti
Sabine Sartoretti
BACKGROUND AND PURPOSE: In postmortem studies, subclinical optic nerve demyelination is very common in patients with MS but radiologic demonstration is difficult and mainly based on STIR T2WI. Our aim was to evaluate 3D double inversion recovery MR imaging for the detection of subclinical demyelinating lesions within optic nerve segments. MATERIALS AND METHODS: The signal intensities in 4 different optic nerve segments (ie, retrobulbar, canalicular, prechiasmatic, and chiasm) were evaluated on 3D double inversion recovery MR imaging in 95 patients with MS without visual symptoms within the past 3 years and in 50 patients without optic nerve pathology. We compared the signal intensities with those of the adjacent lateral rectus muscle. The evaluation was performed by a student group and an expert neuroradiologist. Statistical evaluation (the Cohen κ test) was performed. RESULTS: On the 3D double inversion recovery sequence, optic nerve segments in the comparison group were all hypointense, and an isointense nerve sheath surrounded the retrobulbar nerve segment. At least 1 optic nerve segment was isointense or hyperintense in 68 patients (72%) in the group with MS on the basis of the results of the expert neuroradiologist. Student raters were able to correctly identify optic nerve hypersignal in 97%. CONCLUSIONS: A hypersignal in at least 1 optic nerve segment on the 3D double inversion recovery sequence compared with hyposignal in optic nerve segments in the comparison group was very common in visually asymptomatic patients with MS. The signal-intensity rating of optic nerve segments could also be performed by inexperienced student readers.

1 November 2019 in European Journal of Radiology
Verified
Journal Article
Closed access
TSThomas Sartoretti
Thomas Sartoretti
ESElisabeth Sartoretti
Elisabeth Sartoretti
MWMichael Wyss
Michael Wyss
ÁSÁrpád Schwenk
Árpád Schwenk
LSLuuk van Smoorenburg
Luuk van Smoorenburg
SSSabine Sartoretti
Sabine Sartoretti

16 September 2020 in BMJ Case Reports
Verified
Journal Article
Open access
PDF file
ESElisabeth Sartoretti
Elisabeth Sartoretti
TSThomas Sartoretti
Thomas Sartoretti
RIReinhard Imoberdorf
Reinhard Imoberdorf
JDJan Dracklé
Jan Dracklé
SSSabine Sartoretti
Sabine Sartoretti
A 60-year-old male patient was diagnosed with SARS-CoV-2 infection by positive real-time fluorescence PCR using a nasopharyngeal swab specimen on the second day of symptoms. Due to mild clinical disease course with only cough and temperature up to 37.7°C, the patient was isolated at home for 14 days. The patient had an unremarkable medical history except for arterial hypertension (treated with β1-selective beta-blocker metoprolol) and for bronchial asthma (treated with inhaled topic β2-sympathomimetic agonists, either formoterol or salbutamol, with/without corticosteroids). No familial history of clotting problems was known. On day 14, a subjective improvement with disappearance of fever and cough was noted.