Arash Najafi

Arash Najafi

Auto-generated profile, based on publicly available information

Arash Najafi

Department of Radiology and Nuclear Medicine, Kantonsspital Winterthur, Winterthur, Switzerland

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 April 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ESElisabeth Sartoretti
Elisabeth Sartoretti
TSThomas Sartoretti
Thomas Sartoretti
CBChristoph Binkert
Christoph Binkert
ANArash Najafi
Arash Najafi
ÁSÁrpád Schwenk
Árpád Schwenk
SSSabine Sartoretti
Sabine Sartoretti
Acceleration of MR sequences beyond current parallel imaging techniques is possible with the Compressed SENSE technique that has recently become available for 1.5 and 3 Tesla scanners, for nearly all image contrasts and for 2D and 3D sequences. The impact of this technique on examination timing parameters and MR protocols in a clinical setting was investigated in this retrospective study. A numerical analysis of the examination timing parameters (scan time, exam time, procedure time, interscan delay time, changeover time, nonscan time) based on the MR protocols of 6 different body regions (brain, knee, lumbar spine, breast, shoulder) using MR log files was performed and the total number of examinations acquired from January to April both in 2017 and 2018 on a 1.5 T MR scanner was registered. Percentages, box plots and unpaired two-sided t tests were obtained for statistical evaluation. All examination timing parameters of the six anatomical regions analysed were significantly shortened after implementation of Compressed SENSE. On average, scan times were accelerated by 20.2% (p<0.0001) while procedure times were shortened by 16% (p<0.0001). Considering all anatomical regions and all MR protocols, 27% more examinations were performed over the same 4 month period in 2018 compared to 2017. Compressed SENSE allows for a significant acceleration of MR examinations and a considerable increase in the total number of MR examinations is possible.

8 November 2018 in Insights into Imaging
Verified
Journal Article
Open access
PDF file
TSThomas Sartoretti
Thomas Sartoretti
CRCarolin Reischauer
Carolin Reischauer
ESElisabeth Sartoretti
Elisabeth Sartoretti
CBChristoph Binkert
Christoph Binkert
ANArash Najafi
Arash Najafi
SSSabine Sartoretti
Sabine Sartoretti
Various techniques have been proposed which aim at scan time reduction and/or at improved image quality by increasing the spatial resolution. Compressed sensing (CS) takes advantage of the fact that MR images are usually sparse in some transform domains and recovers this sparse representation from undersampled data. CS may be combined with parallel imaging such as sensitivity encoding (SENSE), hereafter referred to as Compressed SENSE, to further accelerate image acquisition since both techniques rely on different ancillary information. In practice, Compressed SENSE may reduce scan times of two-dimensional (2D) and three-dimensional (3D) scans by up to 50% depending on the sequence acquired and it works on 1.5-T or 3-T scanners. Compressed SENSE may be applied to 2D and 3D sequences in various anatomies and image contrasts. Image artefacts (i.e. motion, metal and flow artefacts, susceptibility artefacts) frequently appear on magnetic resonance images. The Compressed SENSE technique may cause special artefacts, which might influence image assessment if they go undetected by imaging readers. Our institution has been using Compressed SENSE for over half a year, both in a neuroradiological setting and for musculoskeletal examinations. So far, three special image artefacts—called the wax-layer artefact, the streaky-linear artefact and the starry-sky artefact—have been encountered and we aim to review these main artefacts appearing in sequences acquired with Compressed SENSE. • Compressed SENSE combines compressed sensing and SENSE technique. • Compressed SENSE permits scan time reduction and increases spatial image resolution. • Images acquired with Compressed SENSE may present with special artefacts. • Knowledge of artefacts is necessary for reliable image assessment.

1 January 2022 in Radiology
Verified
Journal Article
Closed access
ANArash Najafi
Arash Najafi
MAMarc Al Ahmar
Marc Al Ahmar
Baptiste BonnetBaptiste Bonnet
Baptiste Bonnet
ADAlexandre DELPLA
Alexandre DELPLA
AKAdrian Kobe
Adrian Kobe
LTLambros Tselikas
Lambros Tselikas
For CT-guided percutaneous lung biopsy, positioning biopsy-side down, needle removal during expiration, autologous blood patch sealing, rapid rollover, and pleural patching, or PEARL, reduced pneum... Background Percutaneous CT-guided biopsy of lung nodules is an established method with high diagnostic accuracy but a high rate of pneumothorax and chest tube insertion compared with endobronchial ...

2 August 2019 in Frontiers in Aging Neuroscience
Verified
Journal Article
Open access
TSThomas Sartoretti
Thomas Sartoretti
MWMichael Wyss
Michael Wyss
ESElisabeth Sartoretti
Elisabeth Sartoretti
CRCarolin Reischauer
Carolin Reischauer
NHNicolin Hainc
Nicolin Hainc
SSSabine Sartoretti-Schefer
Sabine Sartoretti-Schefer
Objectives: To assess the influence of age and sex on 10 cerebrospinal fluid (CSF) flow dynamics parameters measured with an MR phase contrast (PC) sequence within the cerebral aqueduct at the level of the intercollicular sulcus. Materials and Methods: 128 healthy subjects (66 female subjects with a mean age of 52.9 years and 62 male subjects with a mean age of 51.8 years) with a normal Evans index, normal medial temporal atrophy (MTA) score, and without known disorders of the CSF circulation were included in the study. A PC MR sequence on a 3T MR scanner was used. Ten different flow parameters were analyzed using postprocessing software. Ordinal and linear regression models were calculated. Results: The parameters stroke volume (sex: p < 0.001, age: p = 0.003), forward flow volume (sex: p < 0.001, age: p = 0.002), backward flow volume (sex: p < 0.001, age: p = 0.018), absolute stroke volume (sex: p < 0.001, age: p = 0.005), mean flux (sex: p < 0.001, age: p = 0.001), peak velocity (sex: p = 0.009, age: p = 0.0016), and peak pressure gradient (sex: p = 0.029, age: p = 0.028) are significantly influenced by sex and age. The parameters regurgitant fraction, stroke distance, and mean velocity are not significantly influenced by sex and age. Conclusion: CSF flow dynamics parameters measured in the cerebral aqueduct are partly age and sex dependent. For establishment of reliable reference values for clinical use in future studies, the impact of sex and age should be considered and incorporated.

1 May 2021 in Radiology: Imaging Cancer
Verified
Journal Article
Closed access
JAJessica Assouline
Jessica Assouline
LTLambros Tselikas
Lambros Tselikas
CRCharles Roux
Charles Roux
SYSteven Yevich
Steven Yevich
ADAlexandre DELPLA
Alexandre DELPLA
FDFrederic Deschamps
Frederic Deschamps
Percutaneous fixation by internal cemented screw can help prevent impending pelvic pathologic fractures in patients with large pelvic bone osteolytic tumors. Purpose To evaluate the efficacy, durability, and safety of percutaneous fixation by internal cemented screw (FICS) for prophylactic consolidation of impending pathologic fractures of the pelvic ri...

1 November 2019 in European Journal of Radiology
Verified
Journal Article
Closed access
TSThomas Sartoretti
Thomas Sartoretti
ESElisabeth Sartoretti
Elisabeth Sartoretti
MWMichael Wyss
Michael Wyss
ÁSÁrpád Schwenk
Árpád Schwenk
LSLuuk van Smoorenburg
Luuk van Smoorenburg
SSSabine Sartoretti
Sabine Sartoretti