Representative Publications

View All Publications
25 September 2021 in Sensors
Verified
Journal Article
Open access
PDF file
SKSUNKU KWON
SUNKU KWON
YKYoungwon Kim
Youngwon Kim
YBYang Bai
Yang Bai
Ryan Donald BurnsRyan Donald Burns
Ryan Donald Burns
Timothy BrusseauTimothy Brusseau
Timothy Brusseau
Wonwoo ByunWonwoo Byun
Wonwoo Byun
The Apple Watch is one of the most popular wearable devices designed to monitor physical activity (PA). However, it is currently unknown whether the Apple Watch accurately estimates children’s free-living PA. Therefore, this study assessed the concurrent validity of the Apple Watch 3 in estimating moderate-to-vigorous physical activity (MVPA) time and active energy expenditure (AEE) for school-aged children under a simulated and a free-living condition. Twenty elementary school students (Girls: 45%, age: 9.7 ± 2.0 years) wore an Apple Watch 3 device on their wrist and performed prescribed free-living activities in a lab setting. A subgroup of participants (N = 5) wore the Apple Watch for seven consecutive days in order to assess the validity in free-living condition. The K5 indirect calorimetry (K5) and GT3X+ were used as the criterion measure under simulated free-living and free-living conditions, respectively. Mean absolute percent errors (MAPE) and Bland-Altman (BA) plots were conducted to assess the validity of the Apple Watch 3 compared to those from the criterion measures. Equivalence testing determined the statistical equivalence between the Apple Watch and K5 for MVPA time and AEE. The Apple Watch provided comparable estimates for MVPA time (mean bias: 0.3 min, p = 0.91, MAPE: 1%) and for AEE (mean bias: 3.8 kcal min, p = 0.75, MAPE: 4%) during the simulated free-living condition. The BA plots indicated no systematic bias for the agreement in MVPA and AEE estimates between the K5 and Apple Watch 3. However, the Apple Watch had a relatively large variability in estimating AEE in children. The Apple Watch was statistically equivalent to the K5 within ±17.7% and ±20.8% for MVPA time and AEE estimates, respectively. Our findings suggest that the Apple Watch 3 has the potential to be used as a PA assessment tool to estimate MVPA in school-aged children.

CPChristopher D Pfledderer
Christopher D Pfledderer
SKSUNKU KWON
SUNKU KWON
Ildiko StrehliIldiko Strehli
Ildiko Strehli
Wonwoo ByunWonwoo Byun
Wonwoo Byun
Ryan Donald BurnsRyan Donald Burns
Ryan Donald Burns
Playgrounds are designed to be a safe, enjoyable, and effective means to promote physical activity in children and adolescents. The purpose of this study was to conduct a meta-analysis to determine the effectiveness of playground interventions for improving accelerometer-assessed ambulatory moderate-to-vigorous physical activity (MVPA) and to identify common aspects of playground interventions that may be beneficial to promote behavior change. An internet database search was performed. The final analyzed sample of studies was obtained from several criteria, including being a playground-based intervention targeting children or adolescents, having a control or comparison group, having an accelerometer-assessed MVPA outcome target variable, and reporting of the mean difference scores’ variability. A random-effects model meta-analysis was employed to obtain pooled effect sizes. Ten studies (n = 10) were analyzed from the internet search. The weighted pooled effect (Hedges’ g) across all studies was Hedges’ g = 0.13, 95% CI: 0.02–0.24, p = 0.023. There was moderate study heterogeneity (I2 = 55.3%) but no evidence for publication bias (p = 0.230). These results suggest that school-based playground interventions have a small effect on increasing accelerometer-assessed MVPA within the pediatric population. The playground should still be an environmental target during school or community-based interventions aimed at providing opportunities to promote MVPA.

18 February 2021 in Sensors
Verified
Journal Article
Open access
PDF file
SKSUNKU KWON
SUNKU KWON
NWNeng Wan
Neng Wan
Ryan Donald BurnsRyan Donald Burns
Ryan Donald Burns
Timothy BrusseauTimothy Brusseau
Timothy Brusseau
YKYoungwon Kim
Youngwon Kim
Wonwoo ByunWonwoo Byun
Wonwoo Byun
MotionSense HRV is a wrist-worn accelerometery-based sensor that is paired with a smartphone and is thus capable of measuring the intensity, duration, and frequency of physical activity (PA). However, little information is available on the validity of the MotionSense HRV. Therefore, the purpose of this study was to assess the concurrent validity of the MotionSense HRV in estimating sedentary behavior (SED) and PA. A total of 20 healthy adults (age: 32.5 ± 15.1 years) wore the MotionSense HRV and ActiGraph GT9X accelerometer (GT9X) on their non-dominant wrist for seven consecutive days during free-living conditions. Raw acceleration data from the devices were summarized into average time (min/day) spent in SED and moderate-to-vigorous PA (MVPA). Additionally, using the Cosemed K5 indirect calorimetry system (K5) as a criterion measure, the validity of the MotionSense HRV was examined in simulated free-living conditions. Pearson correlations, mean absolute percent errors (MAPE), Bland–Altman (BA) plots, and equivalence tests were used to examine the validity of the MotionSense HRV against criterion measures. The correlations between the MotionSense HRV and GT9X were high and the MAPE were low for both the SED (r = 0.99, MAPE = 2.4%) and MVPA (r = 0.97, MAPE = 9.1%) estimates under free-living conditions. BA plots illustrated that there was no systematic bias between the MotionSense HRV and criterion measures. The estimates of SED and MVPA from the MotionSense HRV were significantly equivalent to those from the GT9X; the equivalence zones were set at 16.5% for SED and 29% for MVPA. The estimates of SED and PA from the MotionSense HRV were less comparable when compared with those from the K5. The MotionSense HRV yielded comparable estimates for SED and PA when compared with the GT9X accelerometer under free-living conditions. We confirmed the promising application of the MotionSense HRV for monitoring PA patterns for practical and research purposes.

SKSUNKU KWON
SUNKU KWON
Ryan Donald BurnsRyan Donald Burns
Ryan Donald Burns
YKYoungwon Kim
Youngwon Kim
YBYang Bai
Yang Bai
Wonwoo ByunWonwoo Byun
Wonwoo Byun
This study examined the inter-model agreement between the Fitbit Flex (FF) and FF2 in estimating sedentary behavior (SED) and physical activity (PA) during a free-living condition. 33 healthy adults wore the FF and FF2 on non-dominant wrist for 14 consecutive days. After excluding sleep and non-wear time, data from the FF and FF2 was converted to the time spent (min/day) in SED and PA using a proprietary algorithm. Pearson’s correlation was used to evaluate the association between the estimates from FF and FF2. Mean absolute percent errors (MAPE) were used to examine differences and measurement agreement in SED and PA estimates between FF and FF2. Bland-Altman (BA) plots were used to examine systematic bias between two devices. Equivalence testing was conducted to examine the equivalence between the FF and FF2. The FF2 had strong correlations with the FF in estimating SED and PA times. Compared to the FF, the FF2 yielded similar SED and PA estimates along with relatively low measurement discords and did not have significant systematic biases for SED and Moderate-to-vigorous PA estimates. Our findings suggest that researchers may choose FF2 as a measurement of SED and PA when FF is not available in the market during the longitudinal PA research.

31 October 2025 in JMIR Preprints
Verified
Preprint
Open access
Wonwoo ByunWonwoo Byun
Wonwoo Byun
SKSUNKU KWON
SUNKU KWON
Ryan Donald BurnsRyan Donald Burns
Ryan Donald Burns
EEEmre Ertin
Emre Ertin
NWNeng Wan
Neng Wan
BACKGROUND Wearable accelerometers have become integral to mobile health (mHealth) research, particularly for delivering real-time physical activity (PA) monitoring and applications in interventions such as Just-in-Time Adaptive Interventions (JITAIs). One critical yet underexplored factor in real-time PA monitoring is epoch length, which is the time interval over which raw accelerometry data are aggregated to classify activity intensities and levels. Shorter epochs (e.g., 1 second) enhance precision but increase computational and battery demands, while longer epochs (e.g., 60 seconds) reduce data burden but may miss brief activity bouts. Although previous studies have examined epoch effects using post-processed data, limited evidence exists regarding their influence on real-time, wrist-based PA estimates, especially for moderate-to-vigorous PA (MVPA). Identifying an optimal epoch length for real-time PA measurement remains a critical gap in supporting scalable and efficient mHealth interventions. OBJECTIVE This study determined the impact of varying epoch lengths on real-time MVPA estimates derived from a wrist-worn accelerometer to identify an optimal epoch that balances measurement accuracy with practical feasibility for mHealth applications. METHODS Twenty adults (Age: 32.5 ± 15.1 years) completed a series of carefully selected simulated free-living activities in a controlled laboratory setting. Participants wore the MotionSense HRV wristband, which computed real-time Euclidean Norm Minus One (ENMO) values, and a COSMED K5 indirect calorimetry for metabolic reference. ENMO values were aggregated into 5-, 10-, 15-, 30-, and 60-second epochs. MVPA was classified using validated ENMO cut-points. Epoch-level MVPA estimates were compared against the 1-second reference using mean absolute percent error (MAPE), Pearson’s correlations, Bland-Altman (BA) plots, and equivalence testing with a ±10% equivalence zone. RESULTS MVPA estimates from all epoch lengths were statistically equivalent to the 1-second standard. The 15-second epoch demonstrated the best trade-off between accuracy and efficiency, with minimal bias (0.05 min), low MAPE (6.3%), and strong correlation (r = 0.97). However, indicators of individual-level error increased with longer epochs; MAPE increased to 9.5% at 60 seconds, and the limits of agreement widened (from ± 2.9 min at 15s to ± 4.9 min at 60s), suggesting greater potential misclassifications in estimating MVPA with longer epochs. CONCLUSIONS Although MVPA estimates using the MotionSense HRV wristband were robust across all epoch lengths, findings from this study suggest that a 15-second epoch provides an optimal balance between measurement precision and processing efficiency, making it well-suited for mHealth interventions, such as JITAIs that rely on timely activity detection.