Turbulence is ubiquitous in the universe and in fluid dynamics. It influences a wide range of high energy density systems, from inertial confinement fusion to astrophysical-object evolution. Understanding this phenomenon is crucial, however, due to limitations in experimental and numerical methods in plasma systems, a complete description of the turbulent spectrum is still lacking. Here, we present the measurement of a turbulent spectrum down to micron scale in a laser-plasma experiment. We use an experimental platform, which couples a high power optical laser, an x-ray free-electron laser and a lithium fluoride crystal, to study the dynamics of a plasma flow with micrometric resolution (~1μm) over a large field of view (>1 mm2). After the evolution of a Rayleigh–Taylor unstable system, we obtain spectra, which are overall consistent with existing turbulent theory, but present unexpected features. This work paves the way towards a better understanding of numerous systems, as it allows the direct comparison of experimental results, theory and numerical simulations.
High resolution X-ray imaging is crucial for many high energy density physics (HEDP) experiments. Recently developed techniques to improve resolution have, however, come at the cost of a decreased field of view. In this paper, an innovative experimental detector for X-ray imaging in the context of HEDP experiments with high spatial resolution, as well as a large field of view, is presented. The platform is based on coupling an X-ray backligther source with a Lithium Fluoride detector, characterized by its large dynamic range. A spatial resolution of 2 µm over a field of view greater than 2 mm2 is reported. The platform was benchmarked with both an X-ray free electron laser (XFEL) and an X-ray source produced by a short pulse laser. First, using a non-coherent short pulse laser-produced backlighter, reduced penumbra blurring, as a result of the large size of the X-ray source, is shown. Secondly, we demonstrate phase contrast imaging with a fully coherent monochromatic XFEL beam. Modeling of the absorption and phase contrast transmission of X-ray radiation passing through various targets is presented.
A detailed mathematical model is presented for a submicron-sized cluster formation in a binary gas mixture flowing through a three-staged conical nozzle. By measuring the angular distribution of light scattered from the clusters, the size of CO2 clusters, produced in a supersonic expansion of the mixture gas of CO2(30%)/H2(70%) or CO2(10%)/He(90%), has been evaluated using the Mie scattering method. The mean sizes of CO2 clusters are estimated to be 0.28 ± 0.03 μm for CO2/H2 and 0.26 ± 0.04 μm for CO2/He, respectively. In addition, total gas density profiles in radial direction of the gas jet, measuring the phase shift of the light passing through the target by utilizing an interferometer, are found to be agreed with the numerical modeling within a factor of two. The dryness (= monomer/(monomer + cluster) ratio) in the targets is found to support the numerical modeling. The apparatus developed to evaluate the cluster-gas targets proved that our mathematical model of cluster formation is reliable enough for the binary gas mixture.
The size of CO2 clusters, produced in a supersonic expansion of a mixed-gas of CO2/He or CO2/H2 through a three-staged conical nozzle designed based on the Boldarev's model, has been evaluated by measuring the angular distribution of light scattered from the clusters. The data are analyzed utilizing the Mie scattering theory, and the sizes of CO2 clusters are estimated as 0.22 μm and 0.25 μm for the cases of CO2/He and CO2/H2 gas mixtures, respectively. The results confirm that the Boldarev's model is reliable enough for the production of micron-sized clusters.
The study of heavy ion stopping dynamics using associated K-shell projectile and target radiation was the focus of the reported experiments. Ar, Ca, Ti, and Ni projectile ions with the initial energies of 5.9 and 11.4 MeV/u were slowed down in quartz and arogels. Characteristic radiation of projectiles and target atoms induced in close collisions was registered. The variation of the projectile ion line Doppler shift due to the ion deceleration measured along the ion beam trajectory was used to determine the ion velocity dynamics. The dependence of the ion velocity on the trajectory coordinate was measured over 70–90% of the ion beam path with a spatial resolution of 50–70 μm. The choice of SiO2 aerogel with low mean densities of 0.04–0.15 g/cm3 as a target material, made it possible to stretch the ion stopping range by more than 20–50 times in comparison with solid quartz. It allowed for resolving the dynamics of the ion stopping process. Experimentally, it has been proven that the fine porous nano-structure of aerogels does not affect the ion energy loss and charge state distribution. The strong increase of the ion stopping range in aerogels made it possible to resolve fast ion radiation dynamics. The analysis of the projectile Kα-satellites structure allows supposing that ions propagate in solid in highly exicted states. This can provide an experimental explanation for so called gas-solid effect.