Yaiza Gonzalez-Garcia

Dr. Yaiza Gonzalez-Garcia

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2023 in Journal of Magnesium and Alloys
Verified
Journal Article
Open access
BPB. Pillado
B. Pillado
BMBeatriz Mingo
Beatriz Mingo
Rubén del OlmoRubén del Olmo
Rubén del Olmo
EME. Matykina
E. Matykina
AKA.M. Kooijman
A.M. Kooijman
Marta MohedanoMarta Mohedano
Marta Mohedano

1 April 2021 in Corrosion Science
Verified
Journal Article
Open access
AYA. Yilmaz
A. Yilmaz
KTKonstantina Traka
Konstantina Traka
SPSven Pletincx
Sven Pletincx
THTom Hauffman
Tom Hauffman
Jilt SietsmaJilt Sietsma
Jilt Sietsma
YGYaiza Gonzalez-Garcia
Yaiza Gonzalez-Garcia

15 October 2022 in Carbon
Verified
Journal Article
Open access
ZLZhichao Liu
Zhichao Liu
SBSimona Baluchová
Simona Baluchová
ASAndré F. Sartori
André F. Sartori
ZLZiyu Li
Ziyu Li
YGYaiza Gonzalez-Garcia
Yaiza Gonzalez-Garcia
Josephus BuijnstersJosephus Buijnsters
Josephus Buijnsters

12 July 2023 in Advanced Functional Materials
Verified
Journal Article
Open access
EREhsan Rahimi
Ehsan Rahimi
RSRoger Sanchis‐Gual
Roger Sanchis‐Gual
XCXiangzhong Chen
Xiangzhong Chen
AIAmin Imani
Amin Imani
YGYaiza Gonzalez-Garcia
Yaiza Gonzalez-Garcia
MLMaria Lekka
Maria Lekka
The last two decades have witnessed the emergence of micro‐ and nanoswimmers (MNSs). Researchers have invested significant efforts in engineering motile micro‐ and nanodevices to address current limitations in minimally invasive medicine. MNSs can move through complex fluid media by using chemical fuels or external energy sources such as magnetic fields, ultrasound, or light. Despite significant advancements in their locomotion and functionalities, the gradual deterioration of MNSs in human physiological media is often overlooked. Corrosion and biodegradation caused by chemical reactions with surrounding medium and the activity of biological agents can significantly affect their chemical stability and functional properties during their lifetime performance. It is therefore essential to understand the degradation mechanisms and factors that influence them to design ideal biomedical MNSs that are affordable, highly efficient, and sufficiently resistant to degradation (at least during their service time). This review summarizes recent studies that delve into the physicochemical characteristics and complex environmental factors affecting the corrosion and biodegradation of MNSs, with a focus on metal‐based devices. Additionally, different strategies are discussed to enhance and/or optimize their stability. Conversely, controlled degradation of non‐toxic MNSs can be highly advantageous for numerous biomedical applications, allowing for less invasive, safer, and more efficient treatments.

12 March 2025 in Corrosion Science
Verified
Journal Article
Open access
EBEmad H. Bartawi
Emad H. Bartawi
GSGhada Shaban
Ghada Shaban
CMCalin D. Marioara
Calin D. Marioara
Ehsan RahimiEhsan Rahimi
Ehsan Rahimi
RBRuben Bjørge
Ruben Bjørge
RARajan Ambat
Rajan Ambat

Verified
Journal Article
Open access
PDF file
Hongshan SanHongshan San
Hongshan San
MPMarianne Paresoglou
Marianne Paresoglou
MMMichelle Minneboo
Michelle Minneboo
IHIngmar van Hengel
Ingmar van Hengel
AYAytac Yilmaz
Aytac Yilmaz
Amir A ZadpoorAmir A Zadpoor
Amir A Zadpoor
Nanoparticles (NPs) have high multifunctional potential to simultaneously enhance implant osseointegration and prevent infections caused by antibiotic-resistant bacteria. Here, we present the first report on using plasma electrolytic oxidation (PEO) to incorporate different combinations of reduced graphene oxide (rGO) and silver (Ag) NPs on additively manufactured geometrically ordered volume-porous titanium implants. The rGO nanosheets were mainly embedded parallel with the PEO surfaces. However, the formation of ‘nano-knife’ structures (particles embedded perpendicularly to the implant surfaces) was also found around the pores of the PEO layers. Enhanced in vitro antibacterial activity against methicillin-resistant Staphylococcus aureus was observed for the rGO+Ag-containing surfaces compared to the PEO surfaces prepared only with AgNPs. This was caused by a significant improvement in the generation of reactive oxygen species, higher levels of Ag+ release, and the presence of rGO ‘nano-knife’ structures. In addition, the implants developed in this study stimulated the metabolic activity and osteogenic differentiation of MC3T3-E1 preosteoblast cells compared to the PEO surfaces without nanoparticles. Therefore, the PEO titanium surfaces incorporating controlled levels of rGO+Ag nanoparticles have high clinical potential as multifunctional surfaces for 3D-printed orthopaedic implants.