Danuta Sorysz

Dr. Danuta Sorysz


Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 October 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
PKPawel Kleczynski
Pawel Kleczynski
AKAleksandra Kulbat
Aleksandra Kulbat
PBPiotr Brzychczy
Piotr Brzychczy
Artur DziewierzArtur Dziewierz
Artur Dziewierz
JTJarosław Trȩbacz
Jarosław Trȩbacz
WLWezwanie do zapłatyUNQ435343, Jacek Legutko
Wezwanie do zapłatyUNQ435343, Jacek Legutko
The study aimed to assess procedural complications, patient flow and clinical outcomes after balloon aortic valvuloplasty (BAV) as rescue or bridge therapy, based on data from our registry. A total of 382 BAVs in 374 patients was performed. The main primary indication for BAV was a bridge for TAVI (n = 185, 49.4%). Other indications included a bridge for AVR (n = 26, 6.9%) and rescue procedure in hemodynamically unstable patients (n = 139, 37.2%). The mortality rate at 30 days, 6 and 12 months was 10.4%, 21.6%, 28.3%, respectively. In rescue patients, the death rate raised to 66.9% at 12 months. A significant improvement in symptoms was confirmed after BAV, after 30 days, 6 months, and in survivors after 1 year (p < 0.05 for all). Independent predictors of 12-month mortality were baseline STS score [HR (95% CI) 1.42 (1.34 to 2.88), p < 0.0001], baseline LVEF <20% [HR (95% CI) 1.89 (1.55–2.83), p < 0.0001] and LVEF <30% at 1 month [HR (95% CI) 1.97 (1.62–3.67), p < 0.0001] adjusted for age/gender. In everyday clinical practice in the TAVI era, there are still clinical indications to BAV a standalone procedure as a bridge to surgery, TAVI or for urgent high risk non-cardiac surgical procedures. Patients may improve clinically after BAV with LV function recovery, allowing to perform final therapy, within limited time window, for severe AS which ameliorates long-term outcomes. On the other hand, in patients for whom an isolated BAV becomes a destination therapy, prognosis is extremely poor.

29 April 2016 in Cardiology Journal
Verified
Journal Article
Open access
PDF file
PKPawel Kleczynski
Pawel Kleczynski
Wojciech ZasadaWojciech Zasada
Wojciech Zasada
MBMaciej Bagieński
Maciej Bagieński
ŁRŁukasz Rzeszutko
Łukasz Rzeszutko
DSDanuta Sorysz
Danuta Sorysz
DDDariusz Dudek
Dariusz Dudek
Background: The authors analyzed data from Polish national POL-TAVI registry in terms of paravalvular leak (PVL) occurrence after transcatheter aortic valve implantation (TAVI) and its impact on clinical outcomes. Methods: A total of 331 patients with severe aortic stenosis underwent TAVI (Edwards Sapien, n = 141; CoreValve, n = 190). The grade of PVL and survival rate were assessed at 6-month follow-up. Results: One hundred and eighty-one (54.7%) patients developed mild PVL, and 22 (6.6%) — moderate PVL after TAVI. No severe PVLs were observed. Occurrence of moderate PVL was device dependent and more frequent in the CoreValve group (p = 0.02). Larger CoreValve device used correlated with the grade of PVL (Spearman: r = 0.19; p = 0.01), but for Edwards Sapien devices this correlation was inverted (Spearman: r = –0.62; p = 0.01). Six-month mortality rate was not significant between patients with no or mild PVL compared to those with moderate PVL (p = 0.12). Conclusions: The PVL occurrence remains a frequent problem after TAVI and is device de­pendent, more common with Edwards 23 mm valve and 31 mm CoreValve prosthesis Background: The authors analyzed data from Polish national POL-TAVI registry in terms of paravalvular leak (PVL) occurrence after transcatheter aortic valve implantation (TAVI) and its impact on clinical outcomes. Methods: A total of 331 patients with severe aortic stenosis underwent TAVI (Edwards Sapien, n = 141; CoreValve, n = 190). The grade of PVL and survival rate were assessed at 6-month follow-up. Results: One hundred and eighty-one (54.7%) patients developed mild PVL, and 22 (6.6%) — moderate PVL after TAVI. No severe PVLs were observed. Occurrence of moderate PVL was device dependent and more frequent in the CoreValve group (p = 0.02). Larger CoreValve device used correlated with the grade of PVL (Spearman: r = 0.19; p = 0.01), but for Edwards Sapien devices this correlation was inverted (Spearman: r = –0.62; p = 0.01). Six-month mortality rate was not significant between patients with no or mild PVL compared to those with moderate PVL (p = 0.12). Conclusions: The PVL occurrence remains a frequent problem after TAVI and is device de­pendent, more common with Edwards 23 mm valve and 31 mm CoreValve prosthesis

18 December 2018 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MWMichal Wegiel
Michal Wegiel
Artur DziewierzArtur Dziewierz
Artur Dziewierz
JWJoanna Wojtasik-Bakalarz
Joanna Wojtasik-Bakalarz
DSDanuta Sorysz
Danuta Sorysz
ASAndrzej Surdacki
Andrzej Surdacki
TRTomasz Rakowski
Tomasz Rakowski
According to guidelines, it is safe for low-risk patients with myocardial infarction (MI) to be discharged within 72 h of hospitalization. However, results coming from registries show that the hospital stay is often much longer in a real-life situation. Data on the length of the hospital stay (LOS) of MI patients in Polish centers are lacking. We enrolled 212 consecutive patients with acute MI. Low-risk patients were defined according to PAMI II criteria: age 45%, no persistent ventricular arrhythmia, and no multi-vessel disease (MVD). The median of the hospitalization length was eight days (Q1: 6; Q3: 9). In low-risk patients (25%), the median of LOS was six days (Q1: 5; Q3: 7) (p < 0.001). In a logistic regression analysis patients age, LVEF, ST-segment-elevation MI and the presence of MVD were independent predictors of longer hospitals stay (≥8 days). During follow up, there were no significant differences in the rates of clinical events between patients with shorter (<8 days) and longer (≥8 days) hospitalization. In a real-life situation, the LOS, even in low-risk patients is much longer than recommended in the guidelines.

31 January 2007 in International Journal of Cardiology
Verified
Journal Article
Closed access
ASAndrzej Surdacki
Andrzej Surdacki
BKBogusław Kapelak
Bogusław Kapelak
ABAgata Brzozowska-Czarnek
Agata Brzozowska-Czarnek
WFWiesław Frasik
Wiesław Frasik
AJAgnieszka Jasztal
Agnieszka Jasztal
JDJacek S. Dubiel
Jacek S. Dubiel

1 June 2017
Verified
Journal Article
Closed access
MDMarzena Daniec
Marzena Daniec
Artur DziewierzArtur Dziewierz
Artur Dziewierz
DSDanuta Sorysz
Danuta Sorysz
PKPawel Kleczynski
Pawel Kleczynski
TRTomasz Rakowski
Tomasz Rakowski
DDDariusz Dudek
Dariusz Dudek

22 January 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
DSDanuta Sorysz
Danuta Sorysz
Rafał JanuszekRafał Januszek
Rafał Januszek
ASAnna Sowa-Staszczak
Anna Sowa-Staszczak
AGAnna Grochowska
Anna Grochowska
MOMarta Opalinska
Marta Opalinska
DDDariusz Dudek
Dariusz Dudek
Transcatheter aortic valve implantation (TAVI) is now a well-established treatment for severe aortic stenosis. As the number of procedures and indications increase, the age of patients decreases. However, their durability and factors accelerating the process of degeneration are not well-known. The aim of the study was to verify the possibility of using [18F]F-sodium fluoride ([18F]F-NaF) and [18F]F-fluorodeoxyglucose ([18F]F-FDG) positron emission tomography/computed tomography (PET/CT) in assessing the intensity of TAVI valve degenerative processes. In 73 TAVI patients, transthoracic echocardiography (TTE) at initial (before TAVI), baseline (after TAVI), and during follow-up, as well as transesophageal echocardiography (TEE) and PET/CT, were performed using [18F]F-NaF and [18F]F-FDG at the six-month follow-up (FU) visit as a part of a two-year FU period. The morphology of TAVI valve leaflets were assessed in TEE, transvalvular gradients and effective orifice area (EOA) in TTE. Calcium scores and PET tracer activity were counted. We assessed the relationship between [18F]F-NaF and [18F]F-FDG PET/CT uptake at the 6 = month FU with selected indices e.g.,: transvalvular gradient, valve type, EOA and insufficiency grade at following time points after the TAVI procedure. We present the preliminary PET/CT ([18F]F-NaF, [18F]F-FDG) results at the six-month follow-up period as are part of an ongoing study, which will last two years FU. We enrolled 73 TAVI patients with the mean age of 82.49 ± 7.11 years. A significant decrease in transvalvular gradient and increase of effective orifice area and left ventricle ejection fraction were observed. At six months, FU valve thrombosis was diagnosed in four patients, while 7.6% of patients refused planned controls due to the COVID-19 pandemic. We noticed significant correlations between valve types, EOA and transaortic valve gradients, as well as [18F]F-NaF and [18F]F-FDG uptake in PET/CT. PET/CT imaging with the use of [18F]F-FDG and [18F]F-NaF is intended to be feasible, and it practically allows the standardized uptake value (SUV) to differentiate the area containing the TAVI leaflets from the SUV directly adjacent to the ring calcifications and the calcified native leaflets. This could become the seed for future detection and evaluation capabilities regarding the progression of even early degenerative lesions to the TAVI valve, expressed as local leaflet inflammation and microcalcifications.