Ahmed Elatar

Dr. Ahmed Elatar

Energy and Environmental Science Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831-6070, USA
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 August 2023 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
JRJoseph Rendall
Joseph Rendall
Ahmed ElatarAhmed Elatar
Ahmed Elatar
KNKashif Nawaz
Kashif Nawaz
JSJian Sun
Jian Sun

1 August 2018
Verified
Report
Closed access
PDF file
KNKashif Nawaz
Kashif Nawaz
Ahmed ElatarAhmed Elatar
Ahmed Elatar
BFBrian A. Fricke
Brian A. Fricke
The U.S. Department of Energy's Office of Scientific and Technical Information

22 March 2021 in Energies
Verified
Journal Article
Open access
PDF file
Ahmed ElatarAhmed Elatar
Ahmed Elatar
Brian FrickeBrian Fricke
Brian Fricke
VSVishal Sharma
Vishal Sharma
KNKashif Nawaz
Kashif Nawaz
Trans-critical CO2 vapor compression (VC) refrigeration cycles require a high compression ratio, which is associated with high expansion losses. To recover these expansion losses, a pressure exchange process between the low- and high-pressure sides of the VC cycle is proposed and examined in this study. The proposed pressure exchange system is an open type constant volume process where the high- and low-pressure flows mix inside the system. This prototype is inspired by the pressure exchangers used in reverse-osmosis (RO) desalination systems. In this system, a 2D model was generated and modeled using the computational fluid dynamics (CFD) technique. The numerical model ignored any losses due to leakage or hydraulic friction and the process is considered adiabatic. For the modeling, it was assumed that the inlet conditions for the two pressure exchanger flows are similar to the flow conditions at the evaporator and gas cooler outlets in a VC cycle. Two parameters are examined to test the validity of the system and understand their effect on the performance, including the inlet flow rate represented by the inlet velocity and the process time represented by the speed of rotation. A total of nine cases were simulated and analyzed in this study.

27 June 2025 in Energies
Verified
Journal Article
Open access
PDF file
Ahmed ElatarAhmed Elatar
Ahmed Elatar
Thermo-fluid science is a foundational discipline for numerous mechanical systems, particularly in energy production and building equipment, where thermal and mechanical energy transfer play critical roles

10 July 2025 in Energies
Verified
Journal Article
Open access
PDF file
Ahmed ElatarAhmed Elatar
Ahmed Elatar
JRJoseph Rendall
Joseph Rendall
JSJian Sun
Jian Sun
Jamieson BrechtlJamieson Brechtl
Jamieson Brechtl
KNKashif Nawaz
Kashif Nawaz
Heat pump water heaters (HPWHs) are a proven technology for water heating that has been commercialized. The adoption of HPWHs for domestic and commercial water heating is growing rapidly because of their superior performance compared with alternative water heating methods. Whereas most existing systems use R-134a as a working refrigerant, R290 has gained major attention owing to its superior thermodynamic properties. The goal of the current study is to assess the performance of residential HPWH with R290 as a direct refrigerant replacement for R134a. Two units of a 50 gal HPWH were used in this experimental study. A baseline unit contained R134a refrigerant, and a prototype unit contained R290 refrigerant. The prototype unit was developed through the modification of a commercially available HPWH unit to achieve a low charge of R290 refrigerant. Another major modification was the replacement of the baseline compressor with a compressor designed for R290. Tests were conducted in a field environment (a research and demonstration house) using programmed drawn profiles daily. The prototype that reduced the charge by 43–47% provided displayed performance comparable to the baseline unit regarding first-hour rating (FHR) and the uniform energy factor (UEF).

1 June 2018
Verified
Report
Closed access
PDF file
VBVan D. Baxter
Van D. Baxter
Omar AbdelazizOmar Abdelaziz
Omar Abdelaziz
AAAhmad Abuheiba
Ahmad Abuheiba
KEK. Dean Edwards
K. Dean Edwards
Ahmed ElatarAhmed Elatar
Ahmed Elatar
MZMingkan Zhang
Mingkan Zhang
Refrigerant flammability introduces new challenges to the usage of low global warming potential (Low GWP) refrigerants i n real life applications. Those challenges are centered around the deflagration risk associated with their use and its implications on personal safety. Standards have been developed to systematically set maximum allowable flammable refrigerant charges to ensure safety in case of refrigerant leakage. These standards were initially based on limited testing and numerical analyses of refrigerant leakage into confined spaces.