Muhammad Hanif Ramlee

Dr. Muhammad Hanif Ramlee

Universiti Teknologi Malaysia, Malaysia
+1
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 April 2023 in Materials
Verified
Journal Article
Open access
PDF file
ZSZatul Faqihah Mohd Salaha
Zatul Faqihah Mohd Salaha
Muhammad Imam AmmarullahMuhammad Imam Ammarullah
Muhammad Imam Ammarullah
NIK NUR AIN AZRIN ABDULLAHNIK NUR AIN AZRIN ABDULLAH
NIK NUR AIN AZRIN ABDULLAH
AAAishah Umairah Abd Aziz
Aishah Umairah Abd Aziz
HGHong Seng Gan
Hong Seng Gan
Muhammad Hanif RamleeMuhammad Hanif Ramlee
Muhammad Hanif Ramlee
Total hip arthroplasty (THA) is most likely one of the most successful surgical procedures in medicine. It is estimated that three in four patients live beyond the first post-operative year, so appropriate surgery is needed to alleviate an otherwise long-standing suboptimal functional level. However, research has shown that during a complete THA procedure, a solid hip implant inserted in the femur can damage the main arterial supply of the cortex and damage the medullary space, leading to cortical bone resorption. Therefore, this study aimed to design a porous hip implant with a focus on providing more space for better osteointegration, improving the medullary revascularisation and blood circulation of patients. Based on a review of the literature, a lightweight implant design was developed by applying topology optimisation and changing the materials of the implant. Gyroid and Voronoi lattice structures and a solid hip implant (as a control) were designed. In total, three designs of hip implants were constructed by using SolidWorks and nTopology software version 2.31. Point loads were applied at the x, y and z-axis to imitate the stance phase condition. The forces represented were x = 320 N, y = −170 N, and z = −2850 N. The materials that were used in this study were titanium alloys. All of the designs were then simulated by using Marc Mentat software version 2020 (MSC Software Corporation, Munich, Germany) via a finite element method. Analysis of the study on topology optimisation demonstrated that the Voronoi lattice structure yielded the lowest von Mises stress and displacement values, at 313.96 MPa and 1.50 mm, respectively, with titanium alloys as the materials. The results also indicate that porous hip implants have the potential to be implemented for hip implant replacement, whereby the mechanical integrity is still preserved. This result will not only help orthopaedic surgeons to justify the design choices, but could also provide new insights for future studies in biomechanics.

7 August 2014 in Medical Engineering & Physics
Verified
Journal Article
Closed access
Muhammad Hanif RamleeMuhammad Hanif Ramlee
Muhammad Hanif Ramlee
MKMohammed Rafiq Abdul Kadir
Mohammed Rafiq Abdul Kadir
MMMalliga Raman Murali
Malliga Raman Murali
TKTunku Kamarul
Tunku Kamarul
Pilon fractures are commonly caused by high energy trauma and can result in long-term immobilization of patients. The use of an external fixator i.e. the (1) Delta, (2) Mitkovic or (3) Unilateral frame for treating type III pilon fractures is generally recommended by many experts owing to the stability provided by these constructs. This allows this type of fracture to heal quickly whilst permitting early mobilization. However, the stability of one fixator over the other has not been previously demonstrated. This study was conducted to determine the biomechanical stability of these external fixators in type III pilon fractures using finite element modelling. Three-dimensional models of the tibia, fibula, talus, calcaneus, navicular, cuboid, three cuneiforms and five metatarsal bones were reconstructed from previously obtained CT datasets. Bones were assigned with isotropic material properties, while the cartilage was assigned as hyperelastic springs with Mooney-Rivlin properties. Axial loads of 350 N and 70 N were applied at the tibia to simulate the stance and the swing phase of a gait cycle. To prevent rigid body motion, the calcaneus and metatarsals were fixed distally in all degrees of freedom. The results indicate that the model with the Delta frame produced the lowest relative micromovement (0.03 mm) compared to the Mitkovic (0.05 mm) and Unilateral (0.42 mm) fixators during the stance phase. The highest stress concentrations were found at the pin of the Unilateral external fixator (509.2 MPa) compared to the Mitkovic (286.0 MPa) and the Delta (266.7 MPa) frames. In conclusion, the Delta external fixator was found to be the most stable external fixator for treating type III pilon fractures.

29 May 2020 in Polymers
Verified
Journal Article
Open access
PDF file
Muhammad Umar Aslam KhanMuhammad Umar Aslam Khan
Muhammad Umar Aslam Khan
Hassan MehboobHassan Mehboob
Hassan Mehboob
Saiful Izwan Abd RazakSaiful Izwan Abd Razak
Saiful Izwan Abd Razak
MYMohd Yazid Yahya
Mohd Yazid Yahya
AYAbdul Halim Mohd Yusof
Abdul Halim Mohd Yusof
RARashid Amin
Rashid Amin
Advancement and innovation in bone regeneration, specifically polymeric composite scaffolds, are of high significance for the treatment of bone defects. Xyloglucan (XG) is a polysaccharide biopolymer having a wide variety of regenerative tissue therapeutic applications due to its biocompatibility, in-vitro degradation and cytocompatibility. Current research is focused on the fabrication of polymeric bioactive scaffolds by freeze drying method for nanocomposite materials. The nanocomposite materials have been synthesized from free radical polymerization using n-SiO2 and n-HAp XG and Methacrylic acid (MAAc). Functional group analysis, crystallinity and surface morphology were investigated by Fourier transform infrared spectroscopy (FTIR), X-ray diffraction analysis (XRD) and scanning electron microscopy (SEM) techniques, respectively. These bioactive polymeric scaffolds presented interconnected and well-organized porous morphology, controlled precisely by substantial ratios of n-SiO2. The swelling analysis was also performed in different media at varying temperatures (27, 37 and 47 °C) and the mechanical behavior of the dried scaffolds is also investigated. Antibacterial activities of these scaffolds were conducted against pathogenic gram-positive and gram-negative bacteria. Besides, the biological behavior of these scaffolds was evaluated by the Neutral Red dye assay against the MC3T3-E1 cell line. The scaffolds showed interesting properties for bone tissue engineering, including porosity with substantial mechanical strength, biodegradability, biocompatibility and cytocompatibility behavior. The reported polymeric bioactive scaffolds can be aspirant biomaterials for bone tissue engineering to regenerate defecated bone.

1 March 2019 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
AWAbdul Hadi Abdul Wahab
Abdul Hadi Abdul Wahab
ASAmir Putra Md Saad
Amir Putra Md Saad
MHMuhammad Noor Harun
Muhammad Noor Harun
ASArdiyansyah Syahrom
Ardiyansyah Syahrom
Muhammad Hanif RamleeMuhammad Hanif Ramlee
Muhammad Hanif Ramlee
MKMohammed Rafiq Abdul Kadir
Mohammed Rafiq Abdul Kadir

21 March 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Muhammad Hanif RamleeMuhammad Hanif Ramlee
Muhammad Hanif Ramlee
Muhammad Imam AmmarullahMuhammad Imam Ammarullah
Muhammad Imam Ammarullah
NSNurelisya Suraya Mohd Sukri
Nurelisya Suraya Mohd Sukri
NHNur Syafiqah Faidzul Hassan
Nur Syafiqah Faidzul Hassan
MBMuhammad Hanif Baharuddin
Muhammad Hanif Baharuddin
MKMohammed Rafiq Abdul Kadir
Mohammed Rafiq Abdul Kadir
Previous research has primarily focused on pre-processing parameters such as design, material selection, and printing techniques to improve the strength of 3D-printed prosthetic leg sockets. However, these methods fail to address the major challenges that arise post-printing, namely failures at the distal end of the socket and susceptibility to shear failure. Addressing this gap, the study aims to enhance the mechanical properties of 3D-printed prosthetic leg sockets through post-processing techniques. Fifteen PLA + prosthetic leg sockets are fabricated and reinforced with four materials: carbon fiber, carbon-Kevlar fiber, fiberglass, and cement. Mechanical and microstructural properties of the sockets are evaluated through axial compression testing and scanning electron microscopy (SEM). Results highlight superior attributes of cement-reinforced sockets, exhibiting significantly higher yield strength (up to 89.57% more than counterparts) and higher Young’s modulus (up to 76.15% greater). SEM reveals correlations between microstructural properties and socket strength. These findings deepen the comprehension of 3D-printed prosthetic leg socket post-processing, presenting optimization prospects. Future research can focus on refining fabrication techniques, exploring alternative reinforcement materials, and investigating the long-term durability and functionality of post-processed 3D-printed prosthetic leg sockets.

26 October 2020 in Artificial Intelligence Review
Verified
Journal Article
Closed access
PDF file
HGHong Seng Gan
Hong Seng Gan
Muhammad Hanif RamleeMuhammad Hanif Ramlee
Muhammad Hanif Ramlee
AWAsnida Abdul Wahab
Asnida Abdul Wahab
YLYeng Seng Lee
Yeng Seng Lee
ASAkinobu Shimizu
Akinobu Shimizu