Gandolla Marta

Prof. Gandolla Marta

Department of Mechanical Engineering, Politecnico di Milano, 20133 Milano, Italy
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 August 2022 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
EBElena Bardi
Elena Bardi
GMGandolla Marta
Gandolla Marta
Francesco BraghinFrancesco Braghin
Francesco Braghin
FRFerruccio Resta
Ferruccio Resta
Alessandra PedrocchiAlessandra Pedrocchi
Alessandra Pedrocchi
EAEmilia Ambrosini
Emilia Ambrosini
Introduction: Soft robotic wearable devices, referred to as exosuits, can be a valid alternative to rigid exoskeletons when it comes to daily upper limb support. Indeed, their inherent flexibility improves comfort, usability, and portability while not constraining the user’s natural degrees of freedom. This review is meant to guide the reader in understanding the current approaches across all design and production steps that might be exploited when developing an upper limb robotic exosuit.Methods: The literature research regarding such devices was conducted in PubMed, Scopus, and Web of Science. The investigated features are the intended scenario, type of actuation, supported degrees of freedom, low-level control, high-level control with a focus on intention detection, technology readiness level, and type of experiments conducted to evaluate the device.Results: A total of 105 articles were collected, describing 69 different devices. Devices were grouped according to their actuation type. More than 80% of devices are meant either for rehabilitation, assistance, or both. The most exploited actuation types are pneumatic (52%) and DC motors with cable transmission (29%). Most devices actuate 1 (56%) or 2 (28%) degrees of freedom, and the most targeted joints are the elbow and the shoulder. Intention detection strategies are implemented in 33% of the suits and include the use of switches and buttons, IMUs, stretch and bending sensors, EMG and EEG measurements. Most devices (75%) score a technology readiness level of 4 or 5.Conclusion: Although few devices can be considered ready to reach the market, exosuits show very high potential for the assistance of daily activities. Clinical trials exploiting shared evaluation metrics are needed to assess the effectiveness of upper limb exosuits on target users.

26 January 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Mattia PesentiMattia Pesenti
Mattia Pesenti
AAAlberto Antonietti
Alberto Antonietti
GMGandolla Marta
Gandolla Marta
Alessandra PedrocchiAlessandra Pedrocchi
Alessandra Pedrocchi
While the research interest for exoskeletons has been rising in the last decades, missing standards for their rigorous evaluation are potentially limiting their adoption in the industrial field. In this context, exoskeletons for worker support have the aim to reduce the physical effort required by humans, with dramatic social and economic impact. Indeed, exoskeletons can reduce the occurrence and the entity of work-related musculoskeletal disorders that often cause absence from work, resulting in an eventual productivity loss. This very urgent and multifaceted issue is starting to be acknowledged by researchers. This article provides a systematic review of the state of the art for functional performance evaluation of low-back exoskeletons for industrial workers. We report the state-of-the-art evaluation criteria and metrics used for such a purpose, highlighting the lack of a standard for this practice. Very few studies carried out a rigorous evaluation of the assistance provided by the device. To address also this topic, the article ends with a proposed framework for the functional validation of low-back exoskeletons for the industry, with the aim to pave the way for the definition of rigorous industrial standards.

1 May 2014 in NeuroImage
Verified
Journal Article
Open access
GMGandolla Marta
Gandolla Marta
SFSimona Ferrante
Simona Ferrante
FMFranco Molteni
Franco Molteni
EGEleonora Guanziroli
Eleonora Guanziroli
TFTiziano Frattini
Tiziano Frattini
NWNick S. Ward
Nick S. Ward
The standard account of motor control considers descending outputs from primary motor cortex (M1) as motor commands and efference copy. This account has been challenged recently by an alternative formulation in terms of active inference: M1 is considered as part of a sensorimotor hierarchy providing top–down proprioceptive predictions. The key difference between these accounts is that predictions are sensitive to the current proprioceptive context, whereas efference copy is not. Using functional electric stimulation to experimentally manipulate proprioception during voluntary movement in healthy human subjects, we assessed the evidence for context sensitive output from M1. Dynamic causal modeling of functional magnetic resonance imaging responses showed that FES altered proprioception increased the influence of M1 on primary somatosensory cortex (S1). These results disambiguate competing accounts of motor control, provide some insight into the synaptic mechanisms of sensory attenuation and may speak to potential mechanisms of action of FES in promoting motor learning in neurorehabilitation.

1 January 2016 in Neural Plasticity
Verified
Journal Article
Open access
PDF file
GMGandolla Marta
Gandolla Marta
NWNick S. Ward
Nick S. Ward
FMFranco Molteni
Franco Molteni
EGEleonora Guanziroli
Eleonora Guanziroli
Giancarlo FerrignoGiancarlo Ferrigno
Giancarlo Ferrigno
APAlessandra Pedrocchi
Alessandra Pedrocchi
Neurorehabilitation effective delivery for stroke is likely to be improved by establishing a mechanistic understanding of how to enhance adaptive plasticity. Functional electrical stimulation is effective at reducing poststroke foot drop; in some patients, the effect persists after therapy has finished with an unknown mechanism. We used fMRI to examine neural correlates of functional electrical stimulation key elements, volitional intent to move and concurrent stimulation, in a group of chronic stroke patients receiving functional electrical stimulation for foot-drop correction. Patients exhibited task-related activation in a complex network, sharing bilateral sensorimotor and supplementary motor activation with age-matched controls. We observed consistent separation of patients with and without carryover effect on the basis of brain responses. Patients who experienced the carryover effect had responses in supplementary motor area that correspond to healthy controls; the interaction between experimental factors in contralateral angular gyrus was seen only in those without carryover. We suggest that the functional electrical stimulation carryover mechanism of action is based on movement prediction and sense of agency/body ownership—the ability of a patient to plan the movement and to perceive the stimulation as a part of his/her own control loop is important for carryover effect to take place.

27 September 2016 in Journal of International Medical Research
Verified
Journal Article
Open access
PDF file
GMGandolla Marta
Gandolla Marta
SFSimona Ferrante
Simona Ferrante
GFGiancarlo Ferrigno
Giancarlo Ferrigno
DBDavide Baldassini
Davide Baldassini
FMFranco Molteni
Franco Molteni
APAlessandra Pedrocchi
Alessandra Pedrocchi
Objective To design and implement an electromyography (EMG)-based controller for a hand robotic assistive device, which is able to classify the user's motion intention before the effective kinematic movement execution. Methods Multiple degrees-of-freedom hand grasp movements (i.e. pinching, grasp an object, grasping) were predicted by means of surface EMG signals, recorded from 10 bipolar EMG electrodes arranged in a circular configuration around the forearm 2–3 cm from the elbow. Two cascaded artificial neural networks were then exploited to detect the patient's motion intention from the EMG signal window starting from the electrical activity onset to movement onset (i.e. electromechanical delay). Results The proposed approach was tested on eight healthy control subjects (4 females; age range 25–26 years) and it demonstrated a mean ± SD testing performance of 76% ± 14% for correctly predicting healthy users' motion intention. Two post-stroke patients tested the controller and obtained 79% and 100% of correctly classified movements under testing conditions. Conclusion A task-selection controller was developed to estimate the intended movement from the EMG measured during the electromechanical delay.

22 May 2019 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
GMGandolla Marta
Gandolla Marta
FSFerrante Simona
Ferrante Simona
CACosta Andrea
Costa Andrea
BDBortolotti Dario
Bortolotti Dario
SSSorti Stefano
Sorti Stefano
PAPedrocchi Alessandra
Pedrocchi Alessandra
Aquatic exercises have been demonstrated to benefit the facilitation of motor recovery and the enhancement of well-being in middle-aged adults and the elderly. Personalization, immersiveness, and biofeedback are key for amplifying and accelerating any rehabilitation process in neurological and orthopedic patients. However, a therapist can neither properly visualize nor monitor rehabilitation exercises executed under water, nor can he/she measure them. Therefore, the present study aims to provide adaptive biofeedback during aquatic exercises in order to enhance the training’s effectiveness. A wearable biofeedback suit equipped with wearable underwater-resistant sensor nodes has been designed, produced, and tested. A dedicated algorithm for quantitatively extracting joint angles has been developed and validated against the optical tracking system. Multiple biofeedback modalities are proposed based on visual feedback: amplitude control with set target angles; velocity-amplitude control with set target angles and angular velocity; and velocity tutor with set target angles, a frequency value, and a rest period. Joint angles estimated using the sensor network are compared to those estimated using an optical tracking system with the root-mean-squared angle error between the two systems ranging from 4.0° to 6.3° and a significant correlation coefficient that is always greater than 0.99. Pilot tests during aquatic exercises executed in a thermal environment demonstrate the feasibility and usability of the complete system in the final working environment. The relevant angles are correctly calculated and monitored online during the exercises, and the tested subjects understand the implemented biofeedback modalities easily and follow them well as the SUS evaluation indicates.