Liming Shu

Dr. Liming Shu


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 May 2022 in Journal of Orthopaedic Translation
Verified
Journal Article
Open access
MMMeng Meng
Meng Meng
JWJinzuo Wang
Jinzuo Wang
TSTianze Sun
Tianze Sun
WZWentao Zhang
Wentao Zhang
JZJing Zhang
Jing Zhang
Zhonghai LiZhonghai Li
Zhonghai Li
With increasing requirements for medical effects, and huge differences among individuals, traditional surgical instruments are difficult to meet the patients' growing medical demands. 3D printing is increasingly mature, which connects to medical services critically as well. The patient specific surgical guide plate provides the condition for precision medicine in orthopaedics. In this paper, a systematic review of the orthopedic guide template is presented, where the history of 3D-printing-guided technology, the process of guides, and basic clinical applications of orthopedic guide templates are described. Finally, the limitations of the template and possible future directions are discussed. The technology of 3D printing surgical templates is increasingly mature, standard, and intelligent. With the help of guide templates, the surgeon can easily determine the direction and depth of the screw path, and choose the angle and range of osteotomy, increasing the precision, safety, and reliability of the procedure in various types of surgeries. It simplifies the difficult surgical steps and accelerates the growth of young and mid-career physicians. But some problems such as cost, materials, and equipment limit its development. In different fields of orthopedics, the use of guide templates can significantly improve surgical accuracy, shorten the surgical time, and reduce intraoperative bleeding and radiation. With the development of 3D printing, the guide template will be standardized and simplified from design to production and use. 3D printing guides will be further sublimated in the application of orthopedics and better serve the patients. Precision, intelligence, and individuation are the future development direction of orthopedics. It is more and more popular as the price of printers falls and materials are developed. In addition, the technology of meta-universe, digital twin, and artificial intelligence have made revolutionary effects on template guides. We aim to summarize recent developments and applications of 3D printing guide templates for engineers and surgeons to develop more accurate and efficient templates.

1 August 2018 in Journal of Biomechanics
Verified
Journal Article
Open access
LSLiming Shu
Liming Shu
KYKo Yamamoto
Ko Yamamoto
JYJiang Yao
Jiang Yao
PSPrabhav Saraswat
Prabhav Saraswat
YLYao Liu
Yao Liu
NSNaohiko Sugita
Naohiko Sugita
Concurrent use of finite element (FE) and musculoskeletal (MS) modeling techniques is capable of considering the interactions between prosthetic mechanics and subject dynamics after a total knee replacement (TKR) surgery is performed. However, it still has not been performed in terms of favorable prediction accuracy and systematic experimental validation. In this study, we presented a methodology to develop a subject-specific FE-MS model of a human right lower extremity including the interactions among the subject-specific MS model, the knee joint model with ligament bundles, and the deformable FE prosthesis model. In order to evaluate its accuracy, the FE-MS model was compared with a traditional hinge-constraint MS model and experimentally verified over a gait cycle. Both models achieved good temporal agreement between the predicted muscle force and the electromyography results, though the magnitude on models is different. A higher predicted accuracy, quantified by the root-mean-square error (RMSE) and the squared Pearson correlation coefficient (r2), was found in the FE-MS model (RMSE = 177.2 N, r2 = 0.90) when compared with the MS model (RMSE = 224.1 N, r2 = 0.81) on the total tibiofemoral contact force. The contact mechanics, including the contact area, pressure, and stress were synchronously simulated, and the maximum contact pressure, 22.06 MPa, occurred on the medial side of the tibial insert without exceeding the yield strength of the ultra-high-molecular-weight polyethylene, 24.79 MPa. The approach outlines an accurate knee joint biomechanics analysis and provides an effective method of applying individualized prosthesis design and verification in TKR.

1 March 2015 in Applied Surface Science
Verified
Journal Article
Closed access
YLYande Liang
Yande Liang
LSLiming Shu
Liming Shu
WNWataru Natsu
Wataru Natsu
FHFuben He
Fuben He

1 March 2020 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
LSLiming Shu
Liming Shu
NSNaohiko Sugita
Naohiko Sugita

1 April 2020 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
WBWei Bai
Wei Bai
LSLiming Shu
Liming Shu
RSRonglei Sun
Ronglei Sun
JXJianfeng Xu
Jianfeng Xu
VSVadim V. Silberschmidt
Vadim V. Silberschmidt
NSNaohiko Sugita
Naohiko Sugita

1 July 2020 in International Journal of Machine Tools and Manufacture
Verified
Journal Article
Closed access
LSLiming Shu
Liming Shu
SLShihao Li
Shihao Li
MTMakoto Terashima
Makoto Terashima
WBWei Bai
Wei Bai
THTakayoshi Hanami
Takayoshi Hanami
NSNaohiko Sugita
Naohiko Sugita