Hong Ding

Dr. Hong Ding

Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX 78712, USA
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2017 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
YWYixiang Wang
Yixiang Wang
HDHong Ding
Hong Ding
XLXianhao Le
Xianhao Le
WWWen Wang
Wen Wang
JXJin Xie
Jin Xie

2 May 2019 in Journal of Microelectromechanical Systems
Verified
Journal Article
Closed access
XCXuying Chen
Xuying Chen
JXJinghui Xu
Jinghui Xu
HCHong Chen
Hong Chen
HDHong Ding
Hong Ding
Jin XieJin Xie
Jin Xie
This paper presents a high accuracy air-coupled reflective ultrasonic rangefinder based on piezoelectric micromachined ultrasonic transducers (pMUTs) using multi-frequency continuous waves (MFCWs). Two pieces of 5 times 5 AlN pMUTs arrays at the resonant frequency of 492 kHz are employed to transmit and receive ultrasonic signals, respectively. The MFCW method, where the distance information is calculated from the phase difference, can cancel out the random noise in numerous repeating periods. Therefore, high-accuracy range measurement is achieved. The 3σ accuracy of the short distance measurement (< 100 mm) is 0.0711 mm with 0.096 mm/° first-order resolution and 1.934 μm/° second-order resolution. For long distance measurement (100-300 mm), the 3σ accuracy is 1.8208 mm with 0.481 mm/° first-order resolution and 1.954 μm/° second-order resolution. The MFCW-based rangefinder using pMUTs is a good candidate for short distance measurement with high accuracy. [2018-0267]

11 December 2015 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
PDF file
HDHong Ding
Hong Ding
JZJiuxuan Zhao
Jiuxuan Zhao
BJBing-Feng Ju
Bing-Feng Ju
Jin XieJin Xie
Jin Xie
This paper presents a design and experimental evaluation of a micro-electro-mechanical system biaxial resonant accelerometer with two-stage microleverage mechanisms. The device incorporates two pairs of double-ended tuning fork resonators coupled to a single proof mass. The two-stage microleverage mechanisms possess a higher amplification factor than single-stage microleverage mechanisms, so that the proposed accelerometer has a high level of sensitivity. In addition, a low level of cross-axis sensitivity is realized because of the decoupling beams. The accelerometer is theoretically analyzed and then simulated in the system level by the finite element method. The device is fabricated in a silicon-on-insulator wafer. The experimental results demonstrate that the average differential sensitivity of the resonant accelerometer is 275 Hz g −1 at a resonant frequency of 290 kHz under a polarization voltage of 5 V. The measured cross-axis sensitivity is lower than 3.4%.

8 June 2015 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
JZJiuxuan Zhao
Jiuxuan Zhao
HDHong Ding
Hong Ding
JXJin Xie
Jin Xie
This paper describes an electrostatic charge sensor based on a microelectromechanical systems (MEMS) resonator with dual micro-levers to improve sensitivity. The device comprises a double-ended tuning fork resonant element working at out-of-phase mode with a quality factor (Q) of about 4900 under operating pressure of 40 mTorr. The resonant frequency shifts in proportion to an axial force induced by charge additions and then transformed by dual micro-levers with an amplification factor over 8. The measured responsivity is 1.3×10−3 Hz/fC2 , which matches well with the results from analytical models and finite element method. The sensitivity of the charge sensor is 21 fC under 4 ppm frequency fluctuation. Additionally, electrostatic spring softening and nonlinear feature of the resonator are also investigated.

23 November 2020 in Journal of Microelectromechanical Systems
Verified
Journal Article
Closed access
HDHong Ding
Hong Ding
CWChangju Wu
Changju Wu
Jin XieJin Xie
Jin Xie
This paper reports a micro electromechanical system (MEMS) resonant accelerometer with high relative sensitivity based on sensing scheme of electrostatically-induced stiffness perturbation for the first time. The perturbation electrodes convert the acceleration induced displacement of proof masses to electrostatic perturbation force and cause the effective stiffness perturbation and frequency shift of the resonator. The design of structure dimensions and the application of electrostatically-induced stiffness perturbation lower the resonant frequency and improve the sensitivity, resulting in the improvement of relative sensitivity. The sensing scheme is theoretically analyzed and the device is systematically simulated by finite element analysis (FEA). The open-loop characterization demonstrates that the differential sensitivity is 297.5 Hz/g at resonant frequency of 16.061 kHz under polarization voltage of 50 V. The relative sensitivity, defined as the absolute sensitivity divided by resonant frequency, of 1.8523 %/g is much higher than the traditional resonant accelerometers based on axial force sensing. The bias instability is 0.11 mg and noise floor is 13.2 mg/√ Hz. The performance makes the device a potentially attractive option for highly-sensitive acceleration measurements. [2020-0145]

17 August 2021 in Journal of Microelectromechanical Systems
Verified
Journal Article
Closed access
HDHong Ding
Hong Ding
DYDengfei Yang
Dengfei Yang
MQMengjiao Qu
Mengjiao Qu
CYChao Yang
Chao Yang
XCXuying Chen
Xuying Chen
Jin XieJin Xie
Jin Xie
This letter describes a blood flowmeter by the pulsed wave Doppler (PWD) ultrasound detection procedure utilizing piezoelectric micromachined ultrasonic transducers (pMUTs) with the aluminum nitride (AlN) film as the piezoelectric material. The transceiver electronics for the PWD scheme are constructed for system control and signal processing, and a blood-mimicking fluid (BMF) is synthesized for flow velocity tests. Both the average Doppler frequency-shift and Doppler power spectrum density (PSD) shift with respect to the flow velocity have been characterized and validated, and the flow direction can also be recognized. Finally, a real-time pulsatile flow measurement is demonstrated to emulate the feasibility of monitoring blood flows in practice. [2021-0077]