Yeongtak Song

Dr. Yeongtak Song

Hanyang University College of Medicine, Seoul, Korea
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2016 in Resuscitation
Verified
Journal Article
Closed access
YSYeongtak Song
Yeongtak Song
YCYoungjoon Chee
Youngjoon Chee
JOJaehoon Oh
Jaehoon Oh
Chiwon AhnChiwon Ahn
Chiwon Ahn
TLTae Ho Lim
Tae Ho Lim


28 January 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
SLSeungjae Lee
Seungjae Lee
YSYeongtak Song
Yeongtak Song
Jongshill LeeJongshill Lee
Jongshill Lee
JOJaehoon Oh
Jaehoon Oh
TLTae Ho Lim
Tae Ho Lim
IKIn Young Kim
In Young Kim
Recently, a smart-device-based chest compression depth (CCD) feedback system that helps ensure that chest compressions have adequate depth during cardiopulmonary resuscitation (CPR) was developed. However, no CCD feedback device has been developed for infants, and many feedback systems are inconvenient to use. In this paper, we report the development of a smart-ring-based CCD feedback device for CPR based on an inertial measurement unit, and propose a high-quality chest compression depth estimation algorithm that considers the orientation of the device. The performance of the proposed feedback system was evaluated by comparing it with a linear variable differential transformer in three CPR situations. The experimental results showed compression depth errors of 2.0 ± 1.1, 2.2 ± 0.9, and 1.4 ± 1.1 mm in the three situations. In addition, we conducted a pilot test with an adult/infant mannequin. The results of the experiments show that the proposed smart-ring-based CCD feedback system is applicable to various chest compression methods based on real CPR situations.

Jongbong ChoiJongbong Choi
Jongbong Choi
MLMinhyuk Lee
Minhyuk Lee
YLYangsoon Lee
Yangsoon Lee
YSYeongtak Song
Yeongtak Song
YCYongil Cho
Yongil Cho
TLTae Ho Lim
Tae Ho Lim
Hospital environments are associated with a high risk of infection. As plasma-treated hydrogen peroxide mist disinfection has a higher disinfection efficacy, we tested the efficacy of plasma-treated hydrogen peroxide mist disinfection on several surfaces in various hospital environments. Disinfection was performed in 23 rooms across different hospital environments, including hospital wards, outpatient departments (OPDs), and emergency rooms. A total of 459 surfaces were swabbed before/after disinfection. Surfaces were also divided into plastic, metal, wood, leather, ceramic, silicone, and glass for further analyses. Only gram-positive bacteria were statistically analyzed because the number of gram-negative bacteria and mold was insufficient. Most colony-forming units (CFUs) of gram-positive bacteria were observed in OPDs and on leather materials before disinfection. The proportion of surfaces that showed a percentage decrease in CFU values of more than 90% after disinfection were as follows: OPDs (85%), hospital wards (99%), and emergency rooms (100%); plastic (97%), metal (83%), wood (84%), leather (81%), and others (87%). Plasma-treated hydrogen peroxide mist disinfection resulted in a significant decrease in the CFU values of gram-positive bacteria in various environments. Plasma-treated hydrogen peroxide mist disinfection is an effective and efficient method of disinfecting various hospital environments.

Chiwon AhnChiwon Ahn
Chiwon Ahn
SLSeungjae Lee
Seungjae Lee
Jongshill LeeJongshill Lee
Jongshill Lee
JOJaehoon Oh
Jaehoon Oh
YSYeongtak Song
Yeongtak Song
HKHyunggoo Kang
Hyunggoo Kang
This study aimed to assess the effectiveness of a novel chest compression (CC) smart-ring-based feedback system in a manikin simulation. In this randomized, crossover, controlled study, we evaluated the effect of smart-ring CC feedback on cardiopulmonary resuscitation (CPR). The learnability and usability of the tool were evaluated with the System Usability Scale (SUS). Participants were divided into two groups and each performed CCs with and without feedback 2 weeks apart, using different orders. The primary outcome was compression depth; the proportion of accurate-depth (5–6 cm) CCs, CC rate, and the proportion of complete CCs (≤1 cm of residual leaning) were assessed additionally. The feedback group and the non-feedback group showed significant differences in compression depth (52.1 (46.3–54.8) vs. 47.1 (40.5–49.9) mm, p = 0.021). The proportion of accurate-depth CCs was significantly higher in the interventional than in the control condition (88.7 (30.0–99.1) vs. 22.6 (0.0–58.5%), p = 0.033). The mean SUS score was 83.9 ± 8.7 points. The acceptability ranges were ‘acceptable’, and the adjective rating was ‘excellent’. CCs with smart-ring feedback could help achieve the ideal range of depth during CPR. The smart-ring may be a valuable source of CPR feedback.

19 April 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
HKHyunggoo Kang
Hyunggoo Kang
YLYoonje Lee
Yoonje Lee
SLSanghyun Lee
Sanghyun Lee
YSYeongtak Song
Yeongtak Song
TLTae Ho Lim
Tae Ho Lim
HSHyungoo Shin
Hyungoo Shin
Emergency physicians are at risk of infection during invasive procedures, and wearing a respirator can reduce this risk. The aim of this study was to determine whether the protection afforded by a respirator during intubation is affected by the type of airway device used. In this randomized crossover study, 26 emergency physicians underwent quantitative fit tests for a N95 respirator (cup-type or fold-type) before and during intubation with a direct laryngoscope, GlideScope®, or i-gel® airway device. The primary outcome was the fit factor value of the respirator and the secondary outcome was the level of acceptable protection provided (percentage of fit factor scores above 100). Compared with the GlideScope and i-gel device, the fit factor values and level of acceptable protection provided were lower when physicians wore the cup-type respirator while intubating using the direct laryngoscope (200 fit factor [152–200] and 200 fit factor [121.25–200] versus 166 fit factor [70–200], 100% and 100% versus 75%, respectively; all P < 0.001). There were no significant differences in the fit factor value or level of acceptable protection provided when the physicians wore the fold-type respirator while intubating using any of the three airway devices (all P > 0.05). The type of airway device used for endotracheal intubation may influence the protective performance of some types of respirators. Emergency physicians should consider the effects of airway device types on fit factor of N95 respirators, when they perform intubation at risk of infection.