Background/Aims: Muscle mass depletion has been suggested to predict morbidity and mortality in various diseases. However, it is not well known whether muscle mass depletion is associated with poor outcome in sepsis. We hypothesized that muscle mass depletion is associated with poor outcome in sepsis. Methods: Retrospective observational study was conducted in an emergency department during a 9-year period. Medical records of 627 patients with sepsis were reviewed. We divided the patients into 2 groups according to 28-day mortality and compared the presence of muscle mass depletion assessed by the cross-sectional area of the psoas muscle at the level of the third lumbar vertebra on abdomen CT scans. Univariate and multivariate logistic regression analyses were conducted to examine the association of scarcopenia on the outcome of sepsis. Results: A total of 274 patients with sepsis were finally included in the study: 45 (16.4%) did not survive on 28 days and 77 patients (28.1%) were identified as having muscle mass depletion. The presence of muscle mass depletion was independently associated with 28-day mortality on multivariate logistic analysis (OR 2.79; 95% CI 1.35–5.74, p = 0.01). Conclusions: Muscle mass depletion evaluated by CT scan was associated with poor outcome of sepsis patients. Further studies on the appropriateness of specific treatment for muscle mass depletion with sepsis are needed.
Reducing the time to diagnose COVID-19 helps to manage insufficient isolation-bed resources and adequately accommodate critically ill patients. There is currently no alternative method to real-time reverse transcriptase polymerase chain reaction (RT-PCR), which requires 40 cycles to diagnose COVID-19. We propose a deep learning (DL) model to improve the speed of COVID-19 RT-PCR diagnosis. We developed and tested a DL model using the long short-term memory method with a dataset of fluorescence values measured in each cycle of 5810 RT-PCR tests. Among the DL models developed here, the diagnostic performance of the 21st model showed an area under the receiver operating characteristic (AUROC), sensitivity, and specificity of 84.55%, 93.33%, and 75.72%, respectively. The diagnostic performance of the 24th model showed an AUROC, sensitivity, and specificity of 91.27%, 90.00%, and 92.54%, respectively.
Worldwide, an estimated 6 million patients seek medical attention for burns annually. Various treatment methods and materials have been investigated and developed to enhance burn wound healing. Recently, a new technology, plasma medicine, has emerged to offer new solutions in wound care. As the development of plasma medicine has shown benefit in wound healing, we aimed to assess the effects of plasma medicine on burn wounds. To investigate the effectiveness of a nonthermal atmospheric pressure plasma jet (NAPPJ) for burn wound treatment on a brass comb burn wound rat model. Burn wounds were made by applying a preheated brass comb (100°C) for 2 minutes, which resulted in four full-thickness burn wounds separated by three interspaces. Interspaces were exposed to NAPPJ treatment for 2 minutes and morphological changes and neutrophil infiltration were monitored at 0, 4, and 7 days post-wounding. The percentage of necrotic interspace was higher in the control group than in the plasma-treated group (51.8 ± 20.5% vs 31.5 ± 19.0%, P < .001). Moreover, the exposure of interspace to NAPPJ greatly reduced the number of infiltrating neutrophils. In addition, the percentage of interspace that underwent full-thickness necrosis in the plasma-treated group was smaller than that in the control group (28% vs 67%). NAPPJ exposure on interspaces has a positive effect on burn wounds leading to wound healing by reducing burn injury progression.
Objective The purpose of this study was to assess whether a photoplethysmography (PPG) sensor in a smart watch can accurately recognise the return of spontaneous circulation (ROSC) in cardiac arrest patients compared with carotid artery palpation. Methods This prospective observational study was conducted on 50 out-of-hospital cardiac arrest patients who visited the emergency department (ED) of one tertiary hospital. As soon as the patient arrived at the ED, advanced cardiac life support was carried out immediately. At this time, three smart watches were attached to the carotid artery, forehead and wrist and were checked for pulse measurements every 2 min. In the case of ROSC, blood pressure, heart rate and heart rate regularity were confirmed, and pulse was simultaneously measured at three sites with smart watches. In the case of no ROSC, only the pulse was measured at three sites with the smart watches. Results There were 33 males (66%) and the mean age was 68±11.57 years. In 14 patients (28%), spontaneous circulation was recovered through cardiopulmonary resuscitation, and all survived. The sensitivity and specificity of manual palpation were 78.6% and 90.4%, respectively. False-positive and false-negative rates were 9.6% and 21.4%, respectively. Smart watches at all three sites had the same or higher sensitivity than manual palpation. The sensitivity of the smart watch was the highest, at 100%, in the carotid region and the lowest, at 78.6%, in the wrist region. The specificity of the smart watch was the highest, at 100%, in the wrist region and the lowest, at 78.7%, in the carotid region. Conclusion Compared with manual pulse check, the PPG sensor embedded in the smart watch showed the same sensitivity and a higher specificity for recognising ROSC when measured at the wrist.
The aim of this study was to determine which of 4 laryngoscopes, including A-LRYNGO, a newly developed channel-type video-laryngoscope with an embedded artificial intelligence-based glottis guidance system, is appropriate for tracheal intubation training in novice medical students wearing personal protective equipment (PPE). Thirty healthy senior medical school student volunteers were recruited. The participants underwent 2 tests with 4 laryngoscopes: Macintosh, McGrath, Pentax Airway-Scope and A-LRYNGO. The first test was conducted just after a lecture without any hands-on workshop. The second test was conducted after a one-on-one hands-on workshop. In each test, we measured the time required for tracheal intubation, intubation success rate, etc, and asked all participants to complete a short questionnaire. The time to completely insert the endotracheal tube with the Macintosh laryngoscope did not change significantly (P = .177), but the remaining outcomes significantly improved after the hands-on workshop (all P < .05). Despite being novice practitioners with no intubation experience and wearing PPE, the, 2 channel-type video-laryngoscopes were associated with good intubation-related performance before the hands-on workshop (all P < .001). A-LRYNGO's artificial intelligence-based glottis guidance system showed 93.1% accuracy, but 20.7% of trials were guided by the vocal folds. To prepare to manage the airway of critically ill patients during the coronavirus disease 2019 pandemic, a channel-type video-laryngoscope is appropriate for tracheal intubation training for novice practitioners wearing PPE.