Caterina Monti

Dr. Caterina Monti

Università degli studi di Milano
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 August 2019 in Insights into Imaging
Verified
Journal Article
Open access
PDF file
MZMoreno Zanardo
Moreno Zanardo
ACAndrea Cozzi
Andrea Cozzi
RTRubina Manuela Trimboli
Rubina Manuela Trimboli
OLOlgerta Labaj
Olgerta Labaj
CMCaterina Monti
Caterina Monti
FSFrancesco Sardanelli
Francesco Sardanelli
We reviewed technical parameters, acquisition protocols and adverse reactions (ARs) for contrast-enhanced spectral mammography (CESM). A systematic search in databases, including MEDLINE/EMBASE, was performed to extract publication year, country of origin, study design; patients; mammography unit/vendor, radiation dose, low-/high-energy tube voltage; contrast molecule, concentration and dose; injection modality, ARs and acquisition delay; order of views; examination time. Of 120 retrieved articles, 84 were included from 22 countries (September 2003–January 2019), totalling 14012 patients. Design was prospective in 44/84 studies (52%); in 70/84 articles (83%), a General Electric unit with factory-set kVp was used. Per-view average glandular dose, reported in 12/84 studies (14%), ranged 0.43–2.65 mGy. Contrast type/concentration was reported in 79/84 studies (94%), with Iohexol 350 mgI/mL mostly used (25/79, 32%), dose and flow rate in 72/84 (86%), with 1.5 mL/kg dose at 3 mL/s in 62/72 studies (86%). Injection was described in 69/84 articles (82%), automated in 59/69 (85%), manual in 10/69 (15%) and flush in 35/84 (42%), with 10–30 mL dose in 19/35 (54%). An examination time < 10 min was reported in 65/84 studies (77%), 120 s acquisition delay in 65/84 (77%) and order of views in 42/84 (50%) studies, beginning with the craniocaudal view of the non-suspected breast in 7/42 (17%). Thirty ARs were reported by 14/84 (17%) studies (26 mild, 3 moderate, 1 severe non-fatal) with a pooled rate of 0.82% (fixed-effect model). Only half of CESM studies were prospective; factory-set kVp, contrast 1.5 mL/kg at 3 mL/s and 120 s acquisition delay were mostly used; only 1 severe AR was reported. CESM protocol standardisation is advisable.

11 December 2019 in British Journal of Radiology
Verified
Journal Article
Closed access
CMCaterina Monti
Caterina Monti
MCMarina Codari
Marina Codari
CCCarlo Nicola De Cecco
Carlo Nicola De Cecco
FSFrancesco Secchi
Francesco Secchi
FSFrancesco Sardanelli
Francesco Sardanelli
ASArthur E. Stillman
Arthur E. Stillman
Epicardial adipose tissue (EAT) is a metabolically activated beige adipose tissue, non-homogeneously surrounding the myocardium. Physiologically, EAT regulates toxic fatty acids, protects the coronary arteries against mechanical strain, regulates proinflammatory cytokines, stimulates the production of nitric oxide, reduces oxidative stress, and works as a thermogenic source against hypothermia. Conversely, EAT has pathologic paracrine interactions with the surrounded vessels, and might favour the onset of atrial fibrillation. In addition, initial atherosclerotic lesions can promote inflammation and trigger the EAT production of cytokines increasing vascular inflammation, which, in turn, may help the development of collateral vessels but also of self-stimulating, dysregulated inflammatory process, increasing coronary artery disease severity. Variations in EAT were also linked to metabolic syndrome. Echocardiography first estimated EAT measuring its thickness on the free wall of the right ventricle but does not allow accurate volumetric EAT estimates. Cardiac CT (CCT) and cardiac MR (CMR) allow for three-dimensional EAT estimates, the former showing higher spatial resolution and reproducibility but being limited by radiation exposure and long segmentation times, the latter being radiation-free but limited by lower spatial resolution and reproducibility, higher cost, and difficulties for obese patients. EAT radiodensity at CCT could to be related to underlying metabolic processes. The correlation between EAT and response to certain pharmacological therapies has also been investigated, showing promising results. In the future, semi-automatic or fully automatic techniques, machine/deep-learning methods, if validated, will facilitate research for various EAT measures and may find a place in CCT/CMR reporting.

4 September 2020 in European Radiology
Verified
Journal Article
Open access
PDF file
PSPietro Spagnolo
Pietro Spagnolo
MGManuela Giglio
Manuela Giglio
DMDaniela Di Marco
Daniela Di Marco
PCPaola M. Cannaò
Paola M. Cannaò
EAEustachio Agricola
Eustachio Agricola
FSFrancesco Sardanelli
Francesco Sardanelli
Objectives: The current reference standard for diagnosing LAA thrombi is transesophageal echocardiography (TEE), a semi-invasive technique. We aimed to devise an optimal protocol for cardiac computed tomography (CCT) in diagnosing left atrial appendage (LAA) thrombus in patients with atrial fibrillation (AF), using TEE as reference standard. Methods: Two hundred sixty consecutive patients referred for radiofrequency ablation for AF were prospectively enrolled. All patients underwent CCT and TEE within 2 hours. The CCT protocol included one standard angiographic phase and three delayed acquisitions at 1-, 3-, and 6-min after contrast injection. Thrombi were defined as persisting defects at 6-min delayed acquisition. Results: TEE demonstrated spontaneous contrast in 52 (20%) patients and thrombus in 10 (4%). In 63 patients (24%), CCT demonstrated LAA early filling defects at angiographic phase. Among them, 15 (6%) had a persistent defect at 1-min, 12 (5%) at 3-min, and 10 (4%) at 6-min. All 10 thrombi diagnosed on TEE were correctly identified by delayed CCT, without any false positives. For all phases, sensitivity and negative predictive were 100%. Specificity increased from 79% for the angiographic phase to 100% at 6-min. Positive predictive value increased from 16% to 100%. Estimated radiation exposure was 2.08 ± 0.76 mSv (mean ± standard deviation) for the angiographic phase and 0.45 ± 0.23 mSv for each delayed phase. Conclusion: A CCT protocol adding a 6-min delayed phase to the angiographic phase can be considered optimized for the diagnosis of LAA thrombi, with a low radiation dose. Key Points: • In patients with persistent atrial fibrillation referred for ablation procedures, a cardiac CT examination comprising an angiographic-phase acquisition and, in case of filling defects, a 6-min delayed phase may help reduce the need for transesophageal echocardiography. • Cardiac CT would provide morphological and volumetric data, along with the potential to exclude the presence of thrombi in the left atrial appendage.

2 February 2021 in European Radiology Experimental
Verified
Journal Article
Open access
PDF file
ICIsabella Castiglioni
Isabella Castiglioni
DIDavide Ippolito
Davide Ippolito
MIMatteo Interlenghi
Matteo Interlenghi
CMCaterina Monti
Caterina Monti
CSChristian Salvatore
Christian Salvatore
FSFrancesco Sardanelli
Francesco Sardanelli
Background: We aimed to train and test a deep learning classifier to support the diagnosis of coronavirus disease 2019 (COVID-19) using chest x-ray (CXR) on a cohort of subjects from two hospitals in Lombardy, Italy. Methods: We used for training and validation an ensemble of ten convolutional neural networks (CNNs) with mainly bedside CXRs of 250 COVID-19 and 250 non-COVID-19 subjects from two hospitals (Centres 1 and 2). We then tested such system on bedside CXRs of an independent group of 110 patients (74 COVID-19, 36 non-COVID-19) from one of the two hospitals. A retrospective reading was performed by two radiologists in the absence of any clinical information, with the aim to differentiate COVID-19 from non-COVID-19 patients. Real-time polymerase chain reaction served as the reference standard. Results: At 10-fold cross-validation, our deep learning model classified COVID-19 and non-COVID-19 patients with 0.78 sensitivity (95% confidence interval [CI] 0.74–0.81), 0.82 specificity (95% CI 0.78–0.85), and 0.89 area under the curve (AUC) (95% CI 0.86–0.91). For the independent dataset, deep learning showed 0.80 sensitivity (95% CI 0.72–0.86) (59/74), 0.81 specificity (29/36) (95% CI 0.73–0.87), and 0.81 AUC (95% CI 0.73–0.87). Radiologists’ reading obtained 0.63 sensitivity (95% CI 0.52–0.74) and 0.78 specificity (95% CI 0.61–0.90) in Centre 1 and 0.64 sensitivity (95% CI 0.52–0.74) and 0.86 specificity (95% CI 0.71–0.95) in Centre 2. Conclusions: This preliminary experience based on ten CNNs trained on a limited training dataset shows an interesting potential of deep learning for COVID-19 diagnosis. Such tool is in training with new CXRs to further increase its performance.

5 July 2024 in European Radiology Experimental
Verified
Journal Article
Open access
PDF file
CMCaterina Monti
Caterina Monti
FAFederico Ambrogi
Federico Ambrogi
FSFrancesco Sardanelli
Francesco Sardanelli
Sample size, namely the number of subjects that should be included in a study to reach the desired endpoint and statistical power, is a fundamental concept of scientific research. Indeed, sample size must be planned a priori, and tailored to the main endpoint of the study, to avoid including too many subjects, thus possibly exposing them to additional risks while also wasting time and resources, or too few subjects, failing to reach the desired purpose. We offer a simple, go-to review of methods for sample size calculation for studies concerning data reliability (repeatability/reproducibility) and diagnostic performance. For studies concerning data reliability, we considered Cohen’s κ or intraclass correlation coefficient (ICC) for hypothesis testing, estimation of Cohen’s κ or ICC, and Bland-Altman analyses. With regards to diagnostic performance, we considered accuracy or sensitivity/specificity versus reference standards, the comparison of diagnostic performances, and the comparisons of areas under the receiver operating characteristics curve. Finally, we considered the special cases of dropouts or retrospective case exclusions, multiple endpoints, lack of prior data estimates, and the selection of unusual thresholds for α and β errors. For the most frequent cases, we provide example of software freely available on the Internet.Relevance statement Sample size calculation is a fundamental factor influencing the quality of studies on repeatability/reproducibility and diagnostic performance in radiology.Key points• Sample size is a concept related to precision and statistical power.• It has ethical implications, especially when patients are exposed to risks.• Sample size should always be calculated before starting a study.• This review offers simple, go-to methods for sample size calculations. Graphical Abstract

1 August 2020 in Radiography
Verified
Journal Article
Closed access
MZMoreno Zanardo
Moreno Zanardo
Chiara MartiniChiara Martini
Chiara Martini
CMCaterina Monti
Caterina Monti
FCF. Cattaneo
F. Cattaneo
CCC. Ciaralli
C. Ciaralli
SDS. Durante
S. Durante