Moreno Zanardo

Dr. Moreno Zanardo

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2022 in Radiology
Verified
Journal Article
Closed access
ACAndrea Cozzi
Andrea Cozzi
VMVeronica Magni
Veronica Magni
MZMoreno Zanardo
Moreno Zanardo
SSSimone Schiaffino
Simone Schiaffino
FSFrancesco Sardanelli
Francesco Sardanelli
Contrast-enhanced mammography showed high diagnostic performance in breast cancer detection, particularly when lesion morphologic characteristics and enhancement from both low-energy and recombined... Background Contrast-enhanced mammography (CEM) is a promising technique for breast cancer detection, but conflicting results have been reported in previous meta-analyses. Purpose To perform a syste...

2 August 2019 in Insights into Imaging
Verified
Journal Article
Open access
PDF file
MZMoreno Zanardo
Moreno Zanardo
ACAndrea Cozzi
Andrea Cozzi
RTRubina Manuela Trimboli
Rubina Manuela Trimboli
OLOlgerta Labaj
Olgerta Labaj
CMCaterina Monti
Caterina Monti
FSFrancesco Sardanelli
Francesco Sardanelli
We reviewed technical parameters, acquisition protocols and adverse reactions (ARs) for contrast-enhanced spectral mammography (CESM). A systematic search in databases, including MEDLINE/EMBASE, was performed to extract publication year, country of origin, study design; patients; mammography unit/vendor, radiation dose, low-/high-energy tube voltage; contrast molecule, concentration and dose; injection modality, ARs and acquisition delay; order of views; examination time. Of 120 retrieved articles, 84 were included from 22 countries (September 2003–January 2019), totalling 14012 patients. Design was prospective in 44/84 studies (52%); in 70/84 articles (83%), a General Electric unit with factory-set kVp was used. Per-view average glandular dose, reported in 12/84 studies (14%), ranged 0.43–2.65 mGy. Contrast type/concentration was reported in 79/84 studies (94%), with Iohexol 350 mgI/mL mostly used (25/79, 32%), dose and flow rate in 72/84 (86%), with 1.5 mL/kg dose at 3 mL/s in 62/72 studies (86%). Injection was described in 69/84 articles (82%), automated in 59/69 (85%), manual in 10/69 (15%) and flush in 35/84 (42%), with 10–30 mL dose in 19/35 (54%). An examination time < 10 min was reported in 65/84 studies (77%), 120 s acquisition delay in 65/84 (77%) and order of views in 42/84 (50%) studies, beginning with the craniocaudal view of the non-suspected breast in 7/42 (17%). Thirty ARs were reported by 14/84 (17%) studies (26 mild, 3 moderate, 1 severe non-fatal) with a pooled rate of 0.82% (fixed-effect model). Only half of CESM studies were prospective; factory-set kVp, contrast 1.5 mL/kg at 3 mL/s and 120 s acquisition delay were mostly used; only 1 severe AR was reported. CESM protocol standardisation is advisable.

25 September 2020 in Insights into Imaging
Verified
Journal Article
Open access
PDF file
RTRubina Manuela Trimboli
Rubina Manuela Trimboli
PRPaolo Giorgi Rossi
Paolo Giorgi Rossi
Nicolò Matteo Luca BattistiNicolò Matteo Luca Battisti
Nicolò Matteo Luca Battisti
ACAndrea Cozzi
Andrea Cozzi
VMVeronica Magni
Veronica Magni
FSFrancesco Sardanelli
Francesco Sardanelli
Breast cancer (BC) is the most common female cancer and the second cause of death among women worldwide. The 5-year relative survival rate recently improved up to 90% due to increased population coverage and women’s attendance to organised mammography screening as well as to advances in therapies, especially systemic treatments. Screening attendance is associated with a mortality reduction of at least 30% and a 40% lower risk of advanced disease. The stage at diagnosis remains the strongest predictor of recurrences. Systemic treatments evolved dramatically over the last 20 years: aromatase inhibitors improved the treatment of early-stage luminal BC; targeted monoclonal antibodies changed the natural history of anti-human epidermal growth factor receptor 2-positive (HER2) disease; immunotherapy is currently investigated in patients with triple-negative BC; gene expression profiling is now used with the aim of personalising systemic treatments. In the era of precision medicine, it is a challenging task to define the relative contribution of early diagnosis by screening mammography and systemic treatments in determining BC survival. Estimated contributions before 2000 were 46% for screening and 54% for treatment advances and after 2000, 37% and 63%, respectively. A model showed that the 10-year recurrence rate would be 30% and 25% using respectively chemotherapy or novel treatments in the absence of screening, but would drop to 19% and 15% respectively if associated with mammography screening. Early detection per se has not a curative intent and systemic treatment has limited benefit on advanced stages. Both screening mammography and systemic therapies continue to positively contribute to BC prognosis.

1 May 2021 in Radiography
Verified
Journal Article
Closed access
LRL.A. Rainford
L.A. Rainford
MZMoreno Zanardo
Moreno Zanardo
CBC. Buissink
C. Buissink
RDR. Decoster
R. Decoster
WHW. Hennessy
W. Hennessy
JMJ.P. McNulty
J.P. McNulty

1 August 2020 in Radiography
Verified
Journal Article
Closed access
MZMoreno Zanardo
Moreno Zanardo
Chiara MartiniChiara Martini
Chiara Martini
CMCaterina Monti
Caterina Monti
FCF. Cattaneo
F. Cattaneo
CCC. Ciaralli
C. Ciaralli
SDS. Durante
S. Durante

5 December 2018 in European Radiology Experimental
Verified
Journal Article
Open access
PDF file
MZMoreno Zanardo
Moreno Zanardo
FDFabio M. Doniselli
Fabio M. Doniselli
AEAnastassia Esseridou
Anastassia Esseridou
STStefania Tritella
Stefania Tritella
CMChiara Mattiuz
Chiara Mattiuz
FSFrancesco Sardanelli
Francesco Sardanelli
The contrast agent (CA) dose for abdominal computed tomography (CT) is typically based on patient total body weight (TBW), ignoring adipose tissue distribution. We report on our experience of dosing according to the lean body weight (LBW). After Ethics Committee approval, we retrospectively screened 219 consecutive patients, 18 being excluded for not matching the inclusion criteria. Thus, 201 were analysed (106 males), all undergoing a contrast-enhanced abdominal CT with iopamidol (370 mgI/mL) or iomeprol (400 mgI/mL). LBW was estimated using validated formulas. Liver contrast-enhancement (CEL) was measured. Data were reported as mean ± standard deviation. Pearson correlation coefficient, ANOVA, and the Levene test were used. Mean age was 66 ± 13 years, TBW 72 ± 15 kg, LBW 53 ± 11 kg, and LBW/TBW ratio 74 ± 8%; body mass index was 26 ± 5 kg/m2, with 9 underweight patients (4%), 82 normal weight (41%), 76 overweight (38%), and 34 obese (17%). The administered CA dose was 0.46 ± 0.06 gI/kg of TBW, corresponding to 0.63 ± 0.09 gI/kg of LBW. A negative correlation was found between TBW and CA dose (r = -0.683, p < 0.001). CEL (Hounsfield units) was 51 ± 18 in underweight patients, 44 ± 8 in normal weight, 42 ± 9 in overweight, and 40 ± 6 in obese, with a significant difference for both mean (p = 0.004) and variance (p < 0.001). A low but significant positive correlation was found between CEL and CA dose in gI per TBW (r = 0.371, p < 0.001) or per LBW (r = 0.333, p < 0.001). The injected CA dose was highly variable, with obese patients receiving a lower dose than underweight patients, as a radiologist-driven ‘compensation effect’. Diagnostic abdomen CT examinations may be obtained using 0.63 gI/kg of LBW.