This study deals with the life cycle assessment (LCA) and an exergo-environmental analysis (EEvA) of the geothermal Power Plant of Hellisheiði (Iceland), a combined heat and power double flash plant, with an installed power of 303.3 MW for electricity and 133 MW for hot water. LCA approach is used to evaluate and analyse the environmental performance at the power plant global level. A more in-depth study is developed, at the power plant components level, through EEvA. The analysis employs existing published data with a realignment of the inventory to the latest data resource and compares the life cycle impacts of three methods (ILCD 2011 Midpoint, ReCiPe 2016 Midpoint-Endpoint, and CML-IA Baseline) for two different scenarios. In scenario 1, any emission abatement system is considered. In scenario 2, re-injection of CO2 and H2S is accounted for. The analysis identifies some major hot spots for the environmental power plant impacts, like acidification, particulate matter formation, ecosystem, and human toxicity, mainly caused by some specific sources. Finally, an exergo-environmental analysis allows indicating the wells as significant contributors of the environmental impact rate associated with the construction, Operation & Maintenance, and end of life stages and the HP condenser as the component with the highest environmental cost rate.
The Hellisheidi geothermal power plant, located in Iceland, is a combined heat and power double-flash geothermal plant with an installed capacity of 303.3 MW of electricity and 133 MW of hot water. This study aimed to elucidate the environmental impacts of the electricity and heat production from this double-flash geothermal power plant. In this vein, firstly, the most updated inventory of the plant was generated, and secondly, a life-cycle assessment approach based on the exergy allocation factor was carried out instead of applying the traditionally used allocations in terms of mass and energy. The functional unit was defined as the production of 1 kWh of electricity and 1 kWh of hot water for district heating. The life-cycle stages included the (i) construction, (ii) operation (including abatement operations and maintenance), and (iii) well closure of the geothermal plant. All of the life-cycle stages from construction to dismantling were considered. Finally, the results on the partitioning of the environmental impact to electricity and heat with exergy allocations showed that most of the impact should be charged to electricity, as expected. Furthermore, the distribution of the environmental impacts among the life-cycle stages determined that the construction stage was the most impactful for the electricity and heat production. This result was attributable to the large consumption of steel that was demanded during the construction of the geothermal power plant (geothermal wells, equipment, and buildings). Impacts due to the abatement stage demonstrated that this stage satisfactorily reduced the total impact attributed to the three life-cycle stages of the geothermal power plant.
This work is focused on presenting the main results and discussions concerning the environmental benefits of reducing the non-condensable gases emitted from the Nesjavellir geothermal power plant. The primary objective of this study is to conduct a life cycle evaluation to analyse the overall environmental benefit effects of producing 1 kWh of electricity and 1 kWh of thermal energy in the geothermal power plant at Nesjavellir, which is located in Iceland. The assessment is performed both before and after implementing an abatement system designed to reduce CO2 and H2S gases. The production of geothermal energy is increasing every year and, therefore, it is crucial to identify and quantify the key environmental factors of producing this type of energy and improvements for the future energy transition of the energy generation sector. Firstly, the results show that the environmental impact of electricity production is higher compared to heat production. More in detail, the emissions due to the nature of the geothermal fluid and the construction phase represent the most relevant environmental load for both electricity and heat production for nearly all the 18 environmental impact indicators studied. Furthermore, considering the abatement system for the non-condensable gas emissions, reductions of 78% and 60% in global warming potential is achieved for a production of 1 kWh of electricity and 1 kWh of thermal energy. In terms of external environmental costs, the implementation of an abatement system results in a reduction exceeding 95% for both electricity and thermal energy production per kilowatt-hour. The outcomes obtained from both the baseline scenario and the application of the abatement system undeniably prove that the latter results in a substantial decrease in the overall environmental impacts linked to the generation of 1 kWh of electricity and 1 kWh of heat, encompassing a notable reduction in external environmental costs (externalities).
Qualtra, an innovative 10 MW geothermal power plant proposal, employs a closed-loop design to mitigate emissions, ensuring no direct release into the atmosphere. A thorough assessment utilizing energy and exergy analysis, life cycle assessment (LCA), exergo-economic analysis, and exergo environmental analysis (EevA) was conducted. The LCA results, utilizing the ReCiPe 2016 midpoint methodology, encompass all the spectrum of environmental indicators provided. The technology implemented makes it possible to avoid direct atmospheric emissions from the Qualtra plant, so the environmental impact is mainly due to indirect emissions over the life cycle. The result obtained for the global warming potential indicator is about 6.6 g CO2 eq/kWh, notably lower compared to other conventional systems. Contribution analysis reveals that the construction phase dominates, accounting for over 90% of the impact for almost all LCA midpoint categories, excluding stratospheric ozone depletion, which is dominated by the impact from the operation and maintenance phase, at about 87%. Endpoint indicators were assessed to estimate the single score value using normalization and weighting at the component level. The resulting single score is then used in an Exergo-Environmental Analysis (EEvA), highlighting the well system as the most impactful contributor, constituting approximately 45% of the total impact. Other substantial contributions to the environmental impact include the condenser (21%), the turbine (17%), and the HEGeo (14%). The exergo-economic analysis assesses cost distribution across major plant components, projecting an electricity cost of about 9.4 c€/kWh.