Tanveer Ahmad

Mr. Tanveer Ahmad


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 March 2022 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
TATanveer Ahmad
Tanveer Ahmad
RMRafal Madonski
Rafal Madonski
DZDongdong Zhang
Dongdong Zhang
CHChao Huang
Chao Huang
AMASAD MUJEEB
ASAD MUJEEB

1 May 2021 in Sustainable Cities and Society
Verified
Journal Article
Closed access
TATanveer Ahmad
Tanveer Ahmad
DZDongdong Zhang
Dongdong Zhang

1 May 2019 in Energy
Verified
Journal Article
Closed access
TATanveer Ahmad
Tanveer Ahmad
HCHuanxin Chen
Huanxin Chen

3 March 2023 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
HXHaonan Xie
Haonan Xie
MJMeihui Jiang
Meihui Jiang
DZDongdong Zhang
Dongdong Zhang
Hui Hwang GohHui Hwang Goh
Hui Hwang Goh
TATanveer Ahmad
Tanveer Ahmad
TWThomas Wu
Thomas Wu

6 March 2020 in IEEE Access
Verified
Journal Article
Open access
TATanveer Ahmad
Tanveer Ahmad
DZDongdong Zhang
Dongdong Zhang
The electrical power companies’ load consists of several kinds of customers, for example, agricultural, building, industrial, etc. Agricultural and industrial energy consumption is based on highly inductive loads, and it leads to the electricity shutdown because of highly inductive loads effect large spikes to the power curve. These spikes show their irregular disturbance in the electric power system due to shutdown and start-up of these large loads. It is considered irregular as well as a tough job to forecast the load with the existence of such kinds of spikes. Further, the heterogeneous and multi-source load consumption characteristics necessitate the integration of evolutionary models and the ensemble techniques render better robustness and forecast accuracy. For this purpose, we proposed the novel deep regression and stump treebased ensembles models (DRTSEM) for accurate load planning and management with the use of highly inductive load data, buildings loads, etc. The hyperparameters e.g., network weight decay, network learning rate, the total number of hidden layers and momentum of the DRTSEM is optimized by using the deep regression and stump tree-based algorithms. For forecasting analysis, two different climate zones and seven model’s input model parameter selection (MPS) with new sets of the data samples are used. The forecasting performance is testified with the generalization network error and resubstituting loss, 10-fold cross-validated mean square error, four performance evaluation statistics and existing tree bagger (TB) model. The mean absolute percentage error is noted 47%, 64% and 41% better than the TB model at MPS-3 to MPS-5 respectively. The proposed DRTSEM can efficiently tackle the nonlinear characteristics of the heterogeneous and multi-source loads and moreover increase accuracy and reduce the error between actual and forecasted load demand. The modeling results proved that the use of DRTSEM renders more accurate utility energy planning and management compared with the existing ensemble approaches.

12 August 2021 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
Dongdong ZhangDongdong Zhang
Dongdong Zhang
JYJiawei Yi
Jiawei Yi
HZHongyu Zhu
Hongyu Zhu
TATanveer Ahmad
Tanveer Ahmad
HZHaisen Zhao
Haisen Zhao
TWThomas Wu
Thomas Wu
Compared with the fundamental loss, the harmonic losses become very complicated because of the coupling between the power supply harmonics and the motor harmonics. To dispose of this problem, a multislice 2-D finite element model considering the interbar currents and a fast rotor harmonics identification method is employed to identify the harmonics of the rotor current density and flux density of the inverter-fed induction motor (IM). Considering the complex coupling phenomenon of time–space harmonics, a two-term iron model with piecewise-defined variable coefficients (PVCIL model) and a finite element analysis (FEA)-based copper loss method are then used to calculate the iron and copper loss components of the inverter-fed IM. Finally, based on the introduced methods, both the electromagnetic field and different losses terms of the same 5.5-kW inverter-fed IM under different load and supply conditions are calculated and analyzed. The experimental validation of those two losses’ calculation methods is performed on a 5.5-kW IM with different operating conditions. The results obtained in this article can provide the theoretical basis for targeted harmonic elimination and loss reduction in the design phase of the inverter-fed IM.