Felix von Stetten

Dr. Felix von Stetten

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 November 2018 in The Analyst
Verified
Journal Article
Open access
PDF file
JLJia Li
Jia Li
JMJoanne Macdonald
Joanne Macdonald
FSFelix von Stetten
Felix von Stetten
RPA is a versatile complement or replacement of PCR, and now is stepping into practice.

9 January 2020 in Analytical Methods
Verified
Journal Article
Open access
PDF file
LBLisa Becherer
Lisa Becherer
NBNadine Borst
Nadine Borst
MBMohammed Bakheit
Mohammed Bakheit
SFSieghard Frischmann
Sieghard Frischmann
RZRoland Zengerle
Roland Zengerle
FSFelix von Stetten
Felix von Stetten
In the course of the last 20 years, isothermal nucleic acid amplification tests have emerged as an important diagnostic tool, not only for clinical applications, but also for food quality control and environmental monitoring. Loop-mediated isothermal amplification (LAMP) is well known for its robust and highly sensitive and specific amplification of target DNA, which is achieved by utilizing up to six primers. Moreover, LAMP excels through its isothermal and energy efficient amplification requirements, rendering it a prime candidate for low-cost diagnostics and analysis at the point of need. Recently, methods for sequence-specific detection have gained more importance because, unlike sequence-independent detection methods, they are highly specific towards the target DNA. In the last 13 years, a variety of sequence-specific methods have emerged, based on a very diverse range of sensing techniques, including optical, magnetic, piezoelectric, electrochemical and magnetoresistive sensing. To give structure to the diverse multitude of sequence-specific methods, we created a systematic classification and provide a critical comparative evaluation according to a catalogue of criteria (analytical performance, multiplexing, quantification and instrumental requirements). Fluorescence-based detection, making up half of the methods, can be processed on open platforms and satisfies all the criteria listed before. Instrumental requirements are discussed in terms of complexity, portability and fluidic cartridges. In addition, the technological readiness level and the kind of platform (open versus method-tailored) are evaluated, the latter playing an important role in the miniaturization and automation of operational process steps. We also observe an increase in the use of smartphone-integrated sensors to improve LAMP-based point-of-need testing. In summary, recent developments in methods for the sequence-specific detection of LAMP demonstrate high potential for many future applications.

1 April 2020 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
MTMartin Trotter
Martin Trotter
NBNadine Borst
Nadine Borst
RTRoland Thewes
Roland Thewes
FSFelix von Stetten
Felix von Stetten

23 January 2020 in The Analyst
Verified
Journal Article
Open access
PDF file
JLJia Li
Jia Li
JMJoanne Macdonald
Joanne Macdonald
FSFelix von Stetten
Felix von Stetten
Correction for ‘Review: a comprehensive summary of a decade development of the recombinase polymerase amplification’ by Jia Li et al., Analyst, 2019, 144, 31–67.

22 June 2020 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
MSMartin Schulz
Martin Schulz
SCSilvia Calabrese
Silvia Calabrese
FHFlorian Hausladen
Florian Hausladen
HWHolger Wurm
Holger Wurm
DDDominik Drossart
Dominik Drossart
NBNadine Borst
Nadine Borst
We present an automated point-of-care testing (POCT) system for rapid detection of species- and resistance markers in methicillin-resistant Staphylococcus aureus (MRSA) at the level of single cells, directly from nasal swab samples. Our novel system allows clear differentiation between MRSA, methicillin-sensitive S. aureus (MSSA) and methicillin-resistant coagulase-negative staphylococci (MR-CoNS), which is not the case for currently used real-time quantitative PCR based systems. On top, the novel approach outcompetes the culture-based methods in terms of its short time-to-result (1 h vs. up to 60 h) and reduces manual labor. The walk-away test is fully automated on the centrifugal microfluidic LabDisk platform. The LabDisk cartridge comprises the unit operations swab-uptake, reagent pre-storage, distribution of the sample into 20 000 droplets, specific enzymatic lysis of Staphylococcus spp. and recombinase polymerase amplification (RPA) of species (vicK) – and resistance (mecA) -markers. LabDisk actuation, incubation and multi-channel fluorescence detection is demonstrated with a clinical isolate and spiked nasal swab samples down to a limit of detection (LOD) of 3 ± 0.3 CFU μl−1 for MRSA. The novel approach of the digital single cell detection is suggested to improve hospital admission screening, timely decision making, and goal-oriented antibiotic therapy. The implementation of a higher degree of multiplexing is required to translate the results into clinical practice.

3 March 2016 in Analytical Methods
Verified
Journal Article
Open access
PDF file
FSFriedrich Schuler
Friedrich Schuler
CSClara Siber
Clara Siber
SHSebastian Hin
Sebastian Hin
SWSimon Wadle
Simon Wadle
NPNils Paust
Nils Paust
FSFelix von Stetten
Felix von Stetten
Digital nucleic acid amplification methods are a growing research field that allows for absolute quantification of DNA making the need of standard curves redundant. However, most of the existing digital amplification systems require specialized laboratory devices and costly investments. The required disposable cartridges are device specific and not interchangeable. Here, we present digital droplet loop-mediated isothermal amplification (ddLAMP) as a microfluidic app on standard laboratory devices. ddLAMP is implemented on a disposable polymer chip (DropChip) in the format of a standard microscope slide. After off-chip DNA denaturation, the reaction mix is emulsified in the DropChip in a mini centrifuge for 6 minutes. The DropChip is transferred to an in situ thermal cycler for 1 hour of incubation. Afterwards, a fluorescence scan in a microarray scanner is performed. The DropChip allows for absolute quantification with a dynamic range of 15–1500 DNA copies per μl. Assay conditions were optimized for ddLAMP and comparison of ddPCR and ddLAMP for genomic E. coli DNA reveals very good concordance.