Martin Schulz

Mr. Martin Schulz

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 June 2020 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
MSMartin Schulz
Martin Schulz
SCSilvia Calabrese
Silvia Calabrese
FHFlorian Hausladen
Florian Hausladen
HWHolger Wurm
Holger Wurm
DDDominik Drossart
Dominik Drossart
NBNadine Borst
Nadine Borst
We present an automated point-of-care testing (POCT) system for rapid detection of species- and resistance markers in methicillin-resistant Staphylococcus aureus (MRSA) at the level of single cells, directly from nasal swab samples. Our novel system allows clear differentiation between MRSA, methicillin-sensitive S. aureus (MSSA) and methicillin-resistant coagulase-negative staphylococci (MR-CoNS), which is not the case for currently used real-time quantitative PCR based systems. On top, the novel approach outcompetes the culture-based methods in terms of its short time-to-result (1 h vs. up to 60 h) and reduces manual labor. The walk-away test is fully automated on the centrifugal microfluidic LabDisk platform. The LabDisk cartridge comprises the unit operations swab-uptake, reagent pre-storage, distribution of the sample into 20 000 droplets, specific enzymatic lysis of Staphylococcus spp. and recombinase polymerase amplification (RPA) of species (vicK) – and resistance (mecA) -markers. LabDisk actuation, incubation and multi-channel fluorescence detection is demonstrated with a clinical isolate and spiked nasal swab samples down to a limit of detection (LOD) of 3 ± 0.3 CFU μl−1 for MRSA. The novel approach of the digital single cell detection is suggested to improve hospital admission screening, timely decision making, and goal-oriented antibiotic therapy. The implementation of a higher degree of multiplexing is required to translate the results into clinical practice.

26 November 2015 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
SBS. Burger
S. Burger
MSMartin Schulz
Martin Schulz
FSF. von Stetten
F. von Stetten
RZR. Zengerle
R. Zengerle
NPN. Paust
N. Paust
We present batch-mode mixing for centrifugal microfluidics operated at fixed rotational frequency. Gas is generated by the disk integrated decomposition of hydrogen peroxide (H2O2) to liquid water (H2O) and gaseous oxygen (O2) and inserted into a mixing chamber. There, bubbles are formed that ascent through the liquid in the artificial gravity field and lead to drag flow. Additionaly, strong buoyancy causes deformation and rupture of the gas bubbles and induces strong mixing flows in the liquids. Buoyancy driven bubble mixing is quantitatively compared to shake mode mixing, mixing by reciprocation and vortex mixing. To determine mixing efficiencies in a meaningful way, the different mixers are employed for mixing of a lysis reagent and human whole blood. Subsequently, DNA is extracted from the lysate and the amount of DNA recovered is taken as a measure for mixing efficiency. Relative to standard vortex mixing, DNA extraction based on buoyancy driven bubble mixing resulted in yields of 92 ± 8% (100 s mixing time) and 100 ± 8% (600 s) at 130g centrifugal acceleration. Shake mode mixing yields 96 ± 11% and is thus equal to buoyancy driven bubble mixing. An advantage of buoyancy driven bubble mixing is that it can be operated at fixed rotational frequency, however. The additional costs of implementing buoyancy driven bubble mixing are low since both the activation liquid and the catalyst are very low cost and no external means are required in the processing device. Furthermore, buoyancy driven bubble mixing can easily be integrated in a monolithic manner and is compatible to scalable manufacturing technologies such as injection moulding or thermoforming. We consider buoyancy driven bubble mixing an excellent alternative to shake mode mixing, in particular if the processing device is not capable of providing fast changes of rotational frequency or if the low average rotational frequency is challenging for the other integrated fluidic operations.

21 April 2020 in Molecules
Verified
Journal Article
Open access
PDF file
MSMartin Schulz
Martin Schulz
SPSophia Probst
Sophia Probst
SCSilvia Calabrese
Silvia Calabrese
AHAna R. Homann
Ana R. Homann
NBNadine Borst
Nadine Borst
NPNils Paust
Nils Paust
We present a versatile tool for the generation of monodisperse water-in-fluorinated-oil droplets in standard reaction tubes by centrifugal step emulsification. The microfluidic cartridge is designed as an insert into a standard 2 mL reaction tube and can be processed in standard laboratory centrifuges. It allows for droplet generation and subsequent transfer for any downstream analysis or further use, does not need any specialized device, and manufacturing is simple because it consists of two parts only: A structured substrate and a sealing foil. The design of the structured substrate is compatible to injection molding to allow manufacturing at large scale. Droplets are generated in fluorinated oil and collected in the reaction tube for subsequent analysis. For sample sizes up to 100 µL with a viscosity range of 1 mPa·s–4 mPa·s, we demonstrate stable droplet generation and transfer of more than 6 × 105 monodisperse droplets (droplet diameter 66 µm ± 3 µm, CV ≤ 4%) in less than 10 min. With two application examples, a digital droplet polymerase chain reaction (ddPCR) and digital droplet loop mediated isothermal amplification (ddLAMP), we demonstrate the compatibility of the droplet production for two main amplification techniques. Both applications show a high degree of linearity (ddPCR: R2 ≥ 0.994; ddLAMP: R2 ≥ 0.998), which demonstrates that the cartridge and the droplet generation method do not compromise assay performance.


15 June 2015 in SAE International Journal of Advances and Current Practices in Mobility
Verified
Conference Paper
Closed access
PDF file
MSMartin Schulz
Martin Schulz
Michael SinapiusMichael Sinapius
Michael Sinapius
A designer of a new mechanical ice protection system for airplanes needs to know how much and in which way he has to deform the surface to break off the ice. The ice adhesion strength is often used as a design value. Several methods have been published to measure the adhesive strength of ice. This paper analyzes the interface stresses created by those methods and discusses the way the adhesion strength is derived. A finite element method tool is used to provide insight into the stress state for different load cases. The implication of these illustrations is that equations which use only ultimate force and total interfacial area to calculate adhesion strength miss local stress concentrations and crack nucleation. Hence, the derived adhesion strength may not be comparable within different testing methods, because each testing procedure neglects different parameters like specimen size, substrate thickness and stiffness. In addition the ice adhesion strength is different if peel stress or homogeneous shear stress is applied.Adhesive joint theory can be used to show how to model stress concentrations. Mentioned theory explains why thick ice layers break off more easily, and bending is the most efficient load case to remove ice. Preliminary concepts for new designs of mechanical IPS are given by improving the understanding of stress concentration.

11 November 2014 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
LDLisa Drechsel
Lisa Drechsel
MSMartin Schulz
Martin Schulz
FSFelix von Stetten
Felix von Stetten
CMCarmen Moldovan
Carmen Moldovan
RZRoland Zengerle
Roland Zengerle
NPNils Paust
Nils Paust
Lab-on-a-chip devices hold promise for automation of complex workflows from sample to answer with minimal consumption of reagents in portable devices. However, complex, inhomogeneous samples as they occur in environmental or food analysis may block microchannels and thus often cause malfunction of the system. Here we present the novel AutoDip platform which is based on the movement of a solid phase through the reagents and sample instead of transporting a sequence of reagents through a fixed solid phase. A ball-pen mechanism operated by an external actuator automates unit operations such as incubation and washing by consecutively dipping the solid phase into the corresponding liquids. The platform is applied to electrochemical detection of organophosphorus pesticides in real food samples using an acetylcholinesterase (AChE) biosensor. Minimal sample preparation and an integrated reagent pre-storage module hold promise for easy handling of the assay. Detection of the pesticide chlorpyrifos-oxon (CPO) spiked into apple samples at concentrations of 10−7 M has been demonstrated. This concentration is below the maximum residue level for chlorpyrifos in apples defined by the European Commission.