To evaluate the common sources of diagnostic errors in emergency ultrasonography. The authors performed a Medline search using PubMed (National Library of Medicine, Bethesda, Maryland) for original research and review publications examining the common sources of errors in diagnosis with specific reference to emergency ultrasonography. The search design utilized different association of the following terms : (1) emergency ultrasonography, (2) error, (3) malpractice and (4) medical negligence. This review was restricted to human studies and to English-language literature. Four authors reviewed all the titles and subsequent the abstract of 171 articles that appeared appropriate. Other articles were recognized by reviewing the reference lists of significant papers. Finally, the full text of 48 selected articles was reviewed. Several studies indicate that the etiology of error in emergency ultrasonography is multi-factorial. Common sources of error in emergency ultrasonography are: lack of attention to the clinical history and examination, lack of communication with the patient, lack of knowledge of the technical equipment, use of inappropriate probes, inadequate optimization of the images, failure of perception, lack of knowledge of the possible differential diagnoses, over-estimation of one's own skill, failure to suggest further ultrasound examinations or other imaging techniques. To reduce errors in interpretation of ultrasonographic findings, the sonographer needs to be aware of the limitations of ultrasonography in the emergency setting, and the similarities in the appearances of various physiological and pathological processes. Adequate clinical informations are essential. Diagnostic errors should be considered not as signs of failure, but as learning opportunities.
Variation of the gene coding for D2 receptors (DRD2) has been associated with risk for schizophrenia and with working memory deficits. A functional intronic SNP (rs1076560) predicts relative expression of the two D2 receptors isoforms, D2S (mainly pre-synaptic) and D2L (mainly post-synaptic). However, the effect of functional genetic variation of DRD2 on striatal dopamine D2 signaling and on its correlation with prefrontal activity during working memory in humans is not known. Thirty-seven healthy subjects were genotyped for rs1076560 (G>T) and underwent SPECT with [123I]IBZM (which binds primarily to post-synaptic D2 receptors) and with [123I]FP-CIT (which binds to pre-synaptic dopamine transporters, whose activity and density is also regulated by pre-synaptic D2 receptors), as well as BOLD fMRI during N-Back working memory. Subjects carrying the T allele (previously associated with reduced D2S expression) had striatal reductions of [123I]IBZM and of [123I]FP-CIT binding. DRD2 genotype also differentially predicted the correlation between striatal dopamine D2 signaling (as identified with factor analysis of the two radiotracers) and activity of the prefrontal cortex during working memory as measured with BOLD fMRI, which was positive in GG subjects and negative in GT. Our results demonstrate that this functional SNP within DRD2 predicts striatal binding of the two radiotracers to dopamine transporters and D2 receptors as well as the correlation between striatal D2 signaling with prefrontal cortex activity during performance of a working memory task. These data are consistent with the possibility that the balance of excitatory/inhibitory modulation of striatal neurons may also affect striatal outputs in relationship with prefrontal activity during working memory performance within the cortico-striatal-thalamic-cortical pathway.
124Iodine (124I) with its 4.2 d half-life is particularly attractive forin vivodetection and quantification of longer-term biological and physiological processes; the long half-life of124I is especially suited for prolonged timein vivostudies of high molecular weight compounds uptake. Numerous small molecules and larger compounds like proteins and antibodies have been successfully labeled with124I. Advances in radionuclide production allow the effective availability of sufficient quantities of124I on small biomedical cyclotrons for molecular imaging purposes. Radioiodination chemistry with124I relies on well-established radioiodine labeling methods, which consists mainly in nucleophilic and electrophilic substitution reactions. The physical characteristics of124I permit taking advantages of the higher PET image quality. The availability of new molecules that may be targeted with124I represents one of the more interesting reasons for the attention in nuclear medicine. We aim to discuss all iodine radioisotopes application focusing on124I, which seems to be the most promising for its half-life, radiation emissions, and stability, allowing several applications in oncological and nononcological fields.