Md Tabrez

Dr. Md Tabrez

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 December 2021 in Machines
Verified
Journal Article
Open access
PDF file
MTMohammad Tabrez
Mohammad Tabrez
PSPradip Kumar Sadhu
Pradip Kumar Sadhu
MLMolla Shahadat Hossain Lipu
Molla Shahadat Hossain Lipu
AIAtif Iqbal
Atif Iqbal
MHMohammed Aslam Husain
Mohammed Aslam Husain
SAShaheer Ansari
Shaheer Ansari
Recently, the superiority of multi-phase systems in comparison to three-phase energy systems has been demonstrated with regards to power generation, transmission, distribution, and utilization in particular. Generally, two techniques, specifically semiconductor converter and special transformers (static and passive transformation) have been commonly employed for power generation by utilizing multi-phase systems from the available three-phase power system. The generation of multi-phase power at a fixed frequency by utilizing the static transformation method presents certain advantages compared to semiconductor converters such as reliability, cost-effectiveness, efficiency, and lower total harmonics distortion (THD). Multi-phase transformers are essential to evaluate the parameters of a multi-phase motor, as they require a multi-phase signal that is pure sine wave in nature. However, multi-phase transformers are not suitable for variable frequency applications. Moreover, they have shortcomings with regard to impedance mismatching, the unequal number of turns which lead to inaccurate results in per phase equivalent circuits, which results in an imbalance output in phase voltages and currents. Therefore, this paper aims to investigate multi-phase power transformation from a three-phase system and examine the different static multi-phase transformation techniques. In line with this matter, this study outlines various theories and configurations of transformers, including three-phase to five-, seven-, eleven-, and thirteen-phase transformers. Moreover, the review discusses impedance mismatching, voltage unbalance, and per phase equivalent circuit modeling and fault analysis in multi-phase systems. Moreover, various artificial intelligence-based optimization techniques such as particle swarm optimization (PSO) and the genetic algorithm (GA) are explored to address various existing issues. Finally, the review delivers effective future suggestions that would serve as valuable opportunities, guidelines, and directions for power engineers, industries, and decision-makers to further research on multi-phase transformer improvements towards sustainable operation and management.

9 March 2020 in Microsystem Technologies
Verified
Journal Article
Closed access
PDF file
MTMohammad Tabrez
Mohammad Tabrez
PSPradip Kumar Sadhu
Pradip Kumar Sadhu
AIAtif Iqbal
Atif Iqbal
FBFarhad I. Bakhsh
Farhad I. Bakhsh

22 October 2022 in Energies
Verified
Journal Article
Open access
PDF file
DKDileep kumar
Dileep kumar
SCSurya Deo Choudhary
Surya Deo Choudhary
MTMohammad Tabrez
Mohammad Tabrez
AAAfida Ayob
Afida Ayob
MLMolla Shahadat Hossain Lipu
Molla Shahadat Hossain Lipu
Although brushless direct current motor (BLDCM) drives are becoming more popular in industrial and commercial applications, there are still significant difficulties and unresolved research issues that must be addressed. In BLDCM drives, commutation current ripple (CCR) and diode freewheeling during non-commutation zone (NCZ) are the major challenges. To overcome these limitations, this paper proposes a novel PWM-Model Antiseptic Control (PWM-MAC) technique to alleviate the freewheeling of the diode. The proposed PWM technique is used to alleviate the diode freewheeling in the NCZ, whereas the DCLV circuit is utilized to obtain variable DC-link voltage to address the CCR in the CZ. The MATLAB/Simulink results are included along with experimental results obtained from a laboratory prototype of 325 W. The proposed module reduces the current ripple by 31.7% and corresponding torque ripples are suppressed by approximately 32.5%. This evidences the performance of the proposed control technique.

8 May 2026 in Engineering Research Express
Verified
Journal Article
Closed access
SKSweta Kumari
Sweta Kumari
SCSurya Deo Choudhary
Surya Deo Choudhary
DKDileep Kumar
Dileep Kumar
MTMohammad Tabrez
Mohammad Tabrez
CCChandra Shekhar Singh Chandal
Chandra Shekhar Singh Chandal
SSSaket Kumar Singh
Saket Kumar Singh
A dual band circularly polarized coplanar waveguide - fed microstrip patch antenna consisting of four inverted L grounded strips near the corners and a multi-level vertical stack excited by a 50 Ω impedance microstrip feedline is proposed. The complete dimension of the proposed antenna is only 60 x 60 x 0.8 mm3. The Circular Polarization (CP) is achieved by embedding a pair of inverted - L grounded strips into the square slot and by altering the dimensions of vertical stub. The frequency bandwidth of the proposed antenna is achieved for two bands, from 2.79 GHz to 3.99 GHz with resonating frequency at 3.3 GHz and 3.5 GHz for 5G and WiMAX applications respectively and the other one is from 6.94 GHz to 8.28 GHz featuring a resonating frequency of 7.9 GHz, this design is primarily utilized for satellite communication within the lower X-band for fixed satellite service (FSS) uplink. The uplink frequency from Earth to satellite ranges from 7.9 GHz to 8.4 GHz, making it ideal for applications such as fixed satellite services uplink. VSWR ≤ 2dB is achieved for both the bands and axial ratio (AR) ≤ 3dB is from 2.85 GHz to 3.85 GHz and 7.85 GHz to 8.33 GHz respectively. Performance of the fabricated antenna is experimentally validated and its Return Loss, VSWR, Axial Ratio, Radiation Pattern, Gain, Radiation Efficiency, Surface Current are also observed.

1 September 2020
Verified
Book Chapter
Closed access
PDF file
MTMohammad Tabrez
Mohammad Tabrez
PRPriyansu Raj
Priyansu Raj
RRRahul Raj
Rahul Raj
AGAnubhav Gupta
Anubhav Gupta
SSSaket Kumar Singh
Saket Kumar Singh

25 June 2018 in Preprints.org
Verified
Preprint
Open access
PDF file
MTMohammad Tabrez
Mohammad Tabrez
PSPradip Kumar Sadhu
Pradip Kumar Sadhu
AIAtif Iqbal
Atif Iqbal
FBFarhad Ilahi Bakhsh
Farhad Ilahi Bakhsh
In the recent past, multiphase power generation, power transmission, and electrical drive system are the main focus of research due to their several advantages over three phase. Multiphase drives have better performance over three-phase drives. A multiphase transformer is required at the input of a fixed frequency multiphase drive, rectifier circuit for HVDC applications and multiphase generation and transmission systems. This paper investigates a static three to seven phase conversion technique and presents a design of transformer and control strategy to analyze the effect of unbalanced supply on a three phase to seven phase transformer. The transformer so designed takes three phase as input and seven phase output is obtained at the secondary terminals. The paper also discusses input-output unbalancing. A complete design, analysis, simulation of the proposed technique and experimental validation is presented in this paper. Experimental and simulation results prove that the presented design produced a seven-phase from a tree-phase ac power. Input unbalance is reflected to output but is less than the input unbalance. A seven phase output is not produced if one phase of input is open and the transformer has more than three limbs for flux to flow. A balanced seven phase output in steady state is produced even in one phase open condition for a three limb core type transformer. A new definition of sequence components of an unbalanced seven phase system is defined in this paper.