The global demand for fiber-based products is continuously increasing. The increased consumption and fast fashion current in the global clothing market generate a significant quantity of pre-and post-production waste that ends up in landfills and incinerators. The present study aims to obtain a new waste-based composite material panel for construction applications with improved mechanical properties that can replace traditional wood-based oriented strand boards (OSB). The new composite material is formed by using textile wastes as a reinforcement structure and a combination of bi-oriented polypropylene films (BOPP) waste, polypropylene non-woven materials (TNT) waste and virgin polypropylene fibers (PP) as a matrix. The mechanical properties of waste-based composite materials are modeled using the Taguchi method based on orthogonal arrays to maximize the composite characteristics’ mechanical properties. Experimental data validated the theoretical results obtained.
The production of building materials is a significant component of the impact the construction sector has on the natural environment. Steel is among the most utilized materials, having various applications specific to the built environment. Therefore, understanding the impact of this structural material represents an important step in achieving global sustainable development. The paper aims to analyze the effects of different steel structural elements on the Earth’s ecosystem with respect to concerns over sustainability. In order to reach this goal, the authors have analyzed a dwelling steel structure based on cubic modules with high structural modularity. In addition, the study looks at the influence of an over the floor reinforced concrete slab in order to gain an overall view regarding environmental performances. The impact on the natural environment has been analyzed by considering the cradle-to gate with options Life Cycle Assessment study. The paper provides up-to-date knowledge on the environmental performances of the analyzed structure, presenting encouraging conclusions for construction sector specialists with respect to the use of steel as a material that can represent a solution in the current global effort to minimize the environmental burdens imposed by the construction sector.
Solving the environmental problems and the economic aspects of the construction sector represent a global priority. The considerable quantities of raw materials and the energy consumed by this sector make it one of the most polluting economic activities. Fiberglass in various forms is widely used in the construction sector. In the manufacturing process and during the usage of fiberglass products, a significant amount of indestructible waste results, negatively impacting the environment. An innovative solution for utilizing this type of waste is the treatment with hydrogen plasma. This process results in two products: the first in the gaseous state used to obtain synthetic fuel and the second in solid-state, named slag. The composition of solid waste contains chemical compounds that can increase their strength if used as additives in mortars or concretes. This study presents the laboratory tests on mortars, in which a part of the cement amount was replaced with the solid component resulting from the plasma treatment of glass fiber waste. The results showed that replacing a part of the cement with these materials is a solution that minimizes the ecological footprint of the buildings.
Daylighting design is not only dimensioning glazed surfaces to provide sufficient natural light to an occupied space but also a method of analyzing how this can be achieved without unwanted effects, such as gains and losses of heat, glare, and variations in daylighting intensity at various indoor distances and levels. The case study presented in this paper highlights the energy consumed due to a group of windows with a large glazed area in an existing building located in a temperate continental climate area. The energy consumption results from supplementary artificial lighting required to maintain adequate illumination for indoor activities and to counterbalance heat loss during colder periods are evaluated. The analysis performed by modifying the glazed surface led to the identification of an optimum value of window dimensions for minimum energy consumption. The results of the case study highlight the fact that the evolution of the total energy consumption, evaluated as the sum of the energy consumption due to additional heating/cooling and the artificial lighting required to compensate for the reduction in natural light, is strongly influenced by the dimensions of the glazed surfaces, as well as the minimum level of lighting imposed by the regime of activities carried out in the building. Thus, the outcomes obtained in the research show that at lighting values below 500 lx, the total energy consumption is directly proportional to the glazed surface. From values of 500 lx for the illuminance level, the total energy consumption drops from 2730 kWh/year for a window height of 230 cm to 2399 kWh/year for a height of 110 cm, after which it starts to rise again, reaching a value of 2786 kWh/year for a height of 30 cm. This phenomenon is also found at values higher than 500 lx; accordingly, for an imposed lighting of 1000 lx, the minimum total consumption is identified at a window height of 150 cm. The case study presented in this paper clearly highlights a complex relationship between the height of the glazed surface and the energy consumption required to compensate for heating or cooling and the reduction in natural lighting. Lower window heights reduce heat loss or gain but also correspondingly increase the energy consumption of artificial lighting.
Daylighting design is not only a stage of dimensioning glazed surfaces to provide sufficient natural light to an occupied space, but also a method of analysing how this matter can be achieved without unwanted effects, such as: gains and losses of heat, glare, and variations of the daylighting intensity, at various indoor distances and levels. According to the international regulations in force, glazed surfaces must be designed with a careful balance between the admission of natural light and thermal performance, such as heat loss in winter and heat gain in summer. In a novel project, it is essential to determine the optimal ratio of window-to-wall surface area. This necessity arises because the materials constituting the glazed surfaces of windows typically exhibit lower insulation properties compared to those of the building's walls. This methodology could be applied to building renovations when envelope modifications are possible and suitable. The case study presented in the paper highlights the energy consumed due to a group of windows with a large glazed area in an existing building, located in a temperate continental climate area. The energy consumption results from supplementary artificial lighting required to maintain adequate illumination for indoor activities and that to counterbalance heat loss during colder periods are evaluated. The analysis performed by modifying the glazed surface led to the identification of an optimum value of windows dimensions for an energy consumed minimum.
The construction industry is a key driver of environmental change due to its extensive use of resources and high levels of emissions, thus placing a significant burden on global efforts towards sustainable development targets. A large portion of the environmental footprint of buildings results from the energy required to sustain indoor comfort levels. Therefore, enhancing the energy efficiency of existing buildings becomes critical in reducing their environmental impact. This study examines the influence of increasing thermal performance with the aim of reducing heating demand. Thus, numerical modelling tools and different energy performance assessment meth-odologies have been used. Specifically, it evaluates two existing residential buildings in Romania and compares heating demand predictions using PHPP and Mc001-2022 methodologies across various climatic data sets and case studies. The results reveal significant variability in heating demand predictions, emphasizing the importance of methodological choice and climatic data. The study highlights that both PHPP and Mc001-2022 methodologies yield varying results depending on the specific conditions and characteristics of each building. This variation in results underscores the necessity for a nuanced and context-specific approach to energy performance assessment, in-corporating multiple energy efficiency measures tailored to the unique features of each building.